Skip to content

Galt · Zoning · R1A

Galt R1A zoning: height, setbacks and lot size

In Galt's R1A zone, buildings can be up to 30 ft tall, the front setback is 20 ft and the minimum lot size is 10,000 s.f. (Galt code, read October 2026).

Key points

  • Maximum building height: 30 ft
  • Minimum front setback: 20 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 10 ft
  • Minimum lot size: 10,000 s.f.

R1A is a zoning district in Galt. Every value below was read from the Galt Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R1A

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
30 ft
§ 18.16.050 · code text
Table row “R1A 6,7”, column “Max. Bldg. Height 5”: 30 ft.
Minimum front setback
20 ft
§ 18.16.050 · code text
Table row “R1A 6,7”, column “Front”: 20 ft. 9
Minimum side setback
5 ft
§ 18.16.050 · code text
Table row “R1A 6,7”, column “Side”: 5 ft.
Minimum rear setback
10 ft
§ 18.16.050 · code text
Table row “R1A 6,7”, column “Rear”: 10 ft.
Minimum lot size
10,000 s.f.
§ 18.16.050 · code text
Table row “R1A 6,7”, column “Min. Lot Size”: 10,000 s.f.

Uses in R1A

Uses the code's use tables allow in R1A, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, lot coverage, FAR, density limit for R1A in the zoning tables we read. The code may still set one elsewhere — check the Galt Municipal Code.

Other Galt zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Galt's R1A zone?

30 ft — Galt Municipal Code § 18.16.050.

What is the minimum front setback in Galt's R1A zone?

20 ft — Galt Municipal Code § 18.16.050.

What is the minimum side setback in Galt's R1A zone?

5 ft — Galt Municipal Code § 18.16.050.

What is the minimum rear setback in Galt's R1A zone?

10 ft — Galt Municipal Code § 18.16.050.

What is the minimum lot size in Galt's R1A zone?

10,000 s.f. — Galt Municipal Code § 18.16.050.

General information, not legal advice.

Ask about a Galt property in R1A

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Galt