Skip to content

Galt · Zoning · R4a

Galt R4a zoning: height, setbacks and lot size

In Galt's R4a zone, buildings can be up to 50 ft tall and the front setback is 20 ft (Galt code, read October 2026).

Key points

  • Maximum building height: 50 ft
  • Minimum front setback: 20 ft
  • Minimum side setback: 5 ft (One-story buildings)
  • Minimum rear setback: 10 ft

R4a is a zoning district in Galt. Every value below was read from the Galt Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R4a

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 ft
§ 18.16.050 · code text
Table row “R4a 10”, column “Max. Bldg. Height 5”: 50 ft.
Minimum front setback
20 ft
§ 18.16.050 · code text
Table row “R4a 10”, column “Front”: 20 ft. 9
Minimum side setback
5 ft
Applies: One-story buildings
§ 18.16.050 · code text
Table row “R4a 10”, column “Side”: 5 ft. for one-story buildings; and 10 ft. for two or more story buildings
Minimum rear setback
10 ft
§ 18.16.050 · code text
Table row “R4a 10”, column “Rear”: 10 ft.

When a different number applies

The code sets other values for particular lots, buildings or locations in R4a:

  • Minimum side setback: 10 ft — Two or more story buildings § 18.16.050

Not on this page

We did not find a general stories, lot size, lot coverage, FAR, density limit for R4a in the zoning tables we read. The code may still set one elsewhere — check the Galt Municipal Code.

Other Galt zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Galt's R4a zone?

50 ft — Galt Municipal Code § 18.16.050.

What is the minimum front setback in Galt's R4a zone?

20 ft — Galt Municipal Code § 18.16.050.

What is the minimum side setback in Galt's R4a zone?

5 ft (one-story buildings) — Galt Municipal Code § 18.16.050.

What is the minimum rear setback in Galt's R4a zone?

10 ft — Galt Municipal Code § 18.16.050.

General information, not legal advice.

Ask about a Galt property in R4a

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Galt