Glendale · Zoning · R-2250
Glendale R-2250 zoning: height, setbacks and lot size
In Glendale's R-2250 zone, buildings can be up to 36 ft (3 stories) tall and the front setback is 20 ft minimum and an average of 23 ft (Glendale code, read October 2026).
Key points
- Maximum building height: 36 ft
- Maximum number of stories: 3 stories
- Minimum front setback: 20 ft minimum and an average of 23 ft
- Minimum side setback: 5 ft minimum and an average of 8 ft (for buildings with 3 or more units, a 6 ft minimum may be permitted with additional step-back and modulation requirements)
- Maximum lot coverage: 50%
- Maximum floor area ratio (FAR): 0.85
- Maximum density: 1 dwelling unit per 2,250 sq. ft. of lot area (on lots 90 ft wide or more: 1 dwelling unit per 1,800 sq ft of lot area)
R-2250 is a zoning district in Glendale. Every value below was read from the Glendale Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.
Development standards in R-2250
The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.
| Maximum building height | 36 ft See notes 1, 2, 8 below the table in the code. § 30.11.030 · code textTable row “Height Limits (1) (2) (8)”, column “R-2250”: Maximum of 3 stories and a maximum of 36 feet. Note 1: For multi-family residential buildings containing three units or more, see Chapter 30.17 for additional requirements. Note 2: For lot coverage, setback, height, and landscape open space requirements for solar energy equipment, see Section 30.30.050 . Note 8: For exceptions to height limits for wireless telecommunications facilities, see Chapter 30.48 . |
|---|---|
| Maximum number of stories | 3 stories See notes 1, 2, 8 below the table in the code. § 30.11.030 · code textTable row “Height Limits (1) (2) (8)”, column “R-2250”: Maximum of 3 stories and a maximum of 36 feet. Note 1: For multi-family residential buildings containing three units or more, see Chapter 30.17 for additional requirements. Note 2: For lot coverage, setback, height, and landscape open space requirements for solar energy equipment, see Section 30.30.050 . Note 8: For exceptions to height limits for wireless telecommunications facilities, see Chapter 30.48 . |
| Minimum front setback | 20 ft minimum and an average of 23 ft § 30.11.030 · code textTable row “Street Front”, column “R-2250”: 20 feet minimum and an average of 23 feet. |
| Minimum side setback | 5 ft minimum and an average of 8 ft Applies: for buildings with 3 or more units, a 6 ft minimum may be permitted with additional step-back and modulation requirements See note 4 below the table in the code. § 30.11.030 · code textTable row “Interior”, column “R-2250”: 5 feet minimum and an average of 8 feet. For buildings with 3 or more units, a 6-foot minimum may be permitted with additional step-back and modulation requirements. See Chapter 30.17 . (4) Note 4: For additions to existing dwelling units where only one dwelling unit exists on the lot and for which a building permit was issued prior to December 14, 1995, see Section 30.11.070 . |
| Maximum lot coverage | 50% See note 2 below the table in the code. § 30.11.030 · code textTable row “Lot Coverage (2)”, column “R-2250”: 50% maximum including all residential and accessory buildings Note 2: For lot coverage, setback, height, and landscape open space requirements for solar energy equipment, see Section 30.30.050 . |
| Maximum floor area ratio (FAR) | 0.85 § 30.11.030 · code textTable row “Floor Area Ratio Maximum”, column “R-2250”: .85 |
| Maximum density | 1 dwelling unit per 2,250 sq. ft. of lot area Applies: on lots 90 ft wide or more: 1 dwelling unit per 1,800 sq ft of lot area § 30.11.030 · code textTable row “Residential Density Maximum”, column “R-2250”: 1 dwelling unit for each 2,250 sq. ft. of lot area. On lots having a width of 90 feet or greater, there shall be not more than 1 dwelling unit for each 1,800 sq. ft. of lot area. |
When a different number applies
The code sets other values for particular lots, buildings or locations in R-2250:
- Maximum building height: 50 ft — Multi-family projects on lots with average slope over 10%; flat roofs; envelope height still limited to 36 ft § 30.11.050
- Maximum building height: 55 ft — Multi-family projects on lots with average slope over 10%; roofed area with minimum pitch of 3 in 12; envelope height still limited to 36 ft § 30.11.050
- Minimum side setback: 6 ft — Buildings with 3 or more units: a 6 ft minimum may be permitted with extra step-back and modulation requirements § 30.11.030
- Maximum density: 1 dwelling unit per 1,800 sq. ft. of lot area — Lots having a width of 90 feet or greater § 30.11.030
Not on this page
We did not find a general rear setback, lot size limit for R-2250 in the zoning tables we read. The code may still set one elsewhere — check the Glendale Municipal Code.
Other Glendale zoning districts
Who this affects
Frequently asked questions
What is the maximum building height in Glendale's R-2250 zone?
36 ft — Glendale Municipal Code § 30.11.030.
What is the maximum number of stories in Glendale's R-2250 zone?
3 stories — Glendale Municipal Code § 30.11.030.
What is the minimum front setback in Glendale's R-2250 zone?
20 ft minimum and an average of 23 ft — Glendale Municipal Code § 30.11.030.
What is the minimum side setback in Glendale's R-2250 zone?
5 ft minimum and an average of 8 ft (for buildings with 3 or more units, a 6 ft minimum may be permitted with additional step-back and modulation requirements) — Glendale Municipal Code § 30.11.030.
What is the maximum lot coverage in Glendale's R-2250 zone?
50% — Glendale Municipal Code § 30.11.030.
General information, not legal advice.
Ask about a Glendale property in R-2250
Ask GoCodebook what you can build at a specific address and get an answer that cites the section.
Ask your question