Skip to content

Oakland · Zoning · D-OK-5

Oakland D-OK-5 zoning: height, setbacks and lot size

In Oakland's D-OK-5 zone, generally buildings can be up to 42 ft tall, the front setback is 20 ft and the minimum lot size is 4,000 sq ft, with the conditions listed below (Oakland code, read October 2026).

Key points

  • Maximum building height: 42 ft (maximum wall height, Club Knoll or a replica only; any other building follows the D-OK-4 limit of 30 ft)
  • Minimum front setback: 20 ft
  • Minimum side setback: 20 ft
  • Minimum rear setback: 20 ft
  • Minimum lot size: 4,000 sq ft
  • Maximum floor area ratio (FAR): 0.50

D-OK-5 is a zoning district in Oakland. Every value below was read from the Oakland Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in D-OK-5

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
42 ft
Applies: maximum wall height, Club Knoll or a replica only; any other building follows the D-OK-4 limit of 30 ft
§ 17.101J.050 · code text
Table row “Maximum wall height primary building”, column “D-OK-5”: 42 ft.
Minimum front setback
20 ft
§ 17.101J.050 · code text
Table row “Minimum Front”, column “D-OK-5”: 20 ft.
Minimum side setback
20 ft
§ 17.101J.050 · code text
Table row “Minimum Interior Side”, column “D-OK-5”: 20 ft.
Minimum rear setback
20 ft
§ 17.101J.050 · code text
Table row “Rear”, column “D-OK-5”: 20 ft.
Minimum lot size
4,000 sq ft
§ 17.101J.050 · code text
Table row “Lot area”, column “D-OK-5”: 4,000 sf.
Maximum floor area ratio (FAR)
0.50
§ 17.101J.050 · code text
Table row “Permitted Density”, column “D-OK-5”: 0.50 FAR

When a different number applies

The code sets other values for particular lots, buildings or locations in D-OK-5:

  • Maximum building height: 46 ft — maximum pitched roof height, Club Knoll or a replica only; any other building follows the D-OK-4 limit of 30 ft § 17.101J.050

Not on this page

We did not find a general stories, lot coverage, density limit for D-OK-5 in the zoning tables we read. The code may still set one elsewhere — check the Oakland Municipal Code.

Other Oakland zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Oakland's D-OK-5 zone?

42 ft (maximum wall height, Club Knoll or a replica only; any other building follows the D-OK-4 limit of 30 ft) — Oakland Municipal Code § 17.101J.050.

What is the minimum front setback in Oakland's D-OK-5 zone?

20 ft — Oakland Municipal Code § 17.101J.050.

What is the minimum side setback in Oakland's D-OK-5 zone?

20 ft — Oakland Municipal Code § 17.101J.050.

What is the minimum rear setback in Oakland's D-OK-5 zone?

20 ft — Oakland Municipal Code § 17.101J.050.

What is the minimum lot size in Oakland's D-OK-5 zone?

4,000 sq ft — Oakland Municipal Code § 17.101J.050.

General information, not legal advice.

Ask about an Oakland property in D-OK-5

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Oakland