In Oroville's C-2 zone, generally buildings can be up to 60 feet tall and the front setback is None required, with the conditions listed below (Oroville code, read October 2026).

Key points

  • Maximum building height: 60 feet
  • Minimum front setback: None required (Next to a residential district: that district's front setback, unless a street separates them. 12 ft on Oroville Dam Blvd, Olive Highway, Feather River Blvd.)
  • Minimum side setback: None required (Interior and corner lots. 10 ft on the side next to a residential district.)
  • Minimum rear setback: None required (20 ft if the rear of the site abuts a residential district.)

C-2 is a zoning district in Oroville. Every value below was read from the Oroville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in C-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
60 feet
§ 17.32.020 · code text
Table row “Height, Maximum [1]”, column “C-2”: 60 feet
Minimum front setback
None required
Applies: Next to a residential district: that district's front setback, unless a street separates them. 12 ft on Oroville Dam Blvd, Olive Highway, Feather River Blvd.
§ 17.32.020 · code text
Table row “Front”, column “C-2”: None, except as required in [3] and [4]
Minimum side setback
None required
Applies: Interior and corner lots. 10 ft on the side next to a residential district.
§ 17.32.020 · code text
Table row “Side, interior lot”, column “C-2”: None, except as required in [5] and [6]
Minimum rear setback
None required
Applies: 20 ft if the rear of the site abuts a residential district.
§ 17.32.020 · code text
Table row “Rear”, column “C-2”: None, except as required in [7]

Uses in C-2

Uses the code's use tables allow in C-2, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in C-2:

  • Minimum side setback: 12 feet — Side setback area provides access to a dwelling group § 17.32.020

Not on this page

We did not find a general stories, lot size, lot coverage, FAR, density limit for C-2 in the zoning tables we read. The code may still set one elsewhere — check the Oroville Municipal Code.

Other Oroville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Oroville's C-2 zone?

60 feet — Oroville Municipal Code § 17.32.020.

What is the minimum front setback in Oroville's C-2 zone?

None required (next to a residential district: that district's front setback, unless a street separates them. 12 ft on Oroville Dam Blvd, Olive Highway, Feather River Blvd) — Oroville Municipal Code § 17.32.020.

What is the minimum side setback in Oroville's C-2 zone?

None required (interior and corner lots. 10 ft on the side next to a residential district) — Oroville Municipal Code § 17.32.020.

What is the minimum rear setback in Oroville's C-2 zone?

None required (20 ft if the rear of the site abuts a residential district) — Oroville Municipal Code § 17.32.020.

General information, not legal advice.

Ask about an Oroville property in C-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Oroville