Skip to content

Sausalito · Zoning · PR

Sausalito PR zoning: height, setbacks and lot size

In Sausalito's PR zone, generally buildings can be up to 32 feet tall, the front setback is 0 feet and the minimum lot size is 20,000 sf, with the conditions listed below (Sausalito code, read October 2026).

Key points

  • Maximum building height: 32 feet
  • Minimum front setback: 0 feet (10 ft where designated on the zoning map)
  • Minimum side setback: 5 feet
  • Minimum rear setback: 15 feet
  • Minimum lot size: 20,000 sf
  • Maximum lot coverage: 50%
  • Maximum floor area ratio (FAR): 0.65
  • Maximum density: 1 du/1980 sf

PR is a zoning district in Sausalito. Every value below was read from the Sausalito Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in PR

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
32 feet
§ 10.22.040 · code text
Table row “Maximum building height 11”, column “PR”: 32 feet
Minimum front setback
0 feet
Applies: 10 ft where designated on the zoning map
§ 10.22.040 · code text
Table row “Front 8”, column “PR”: 0 feet
Minimum side setback
5 feet
§ 10.22.040 · code text
Table row “Side 9”, column “PR”: 5 feet
Minimum rear setback
15 feet
§ 10.22.040 · code text
Table row “Rear 10”, column “PR”: 15 feet
Minimum lot size
20,000 sf
§ 10.22.040 · code text
Table row “Minimum parcel size 2”, column “PR”: 20,000 sf
Maximum lot coverage
50%
§ 10.22.040 · code text
Table row “Maximum building coverage”, column “PR”: 50%
Maximum floor area ratio (FAR)
0.65
§ 10.22.040 · code text
Table row “Maximum floor area ratio 13”, column “PR”: .65
Maximum density
1 du/1980 sf
§ 10.22.040 · code text
Table row “Maximum density”, column “PR”: 1 du/1980 sf

Not on this page

We did not find a general stories limit for PR in the zoning tables we read. The code may still set one elsewhere — check the Sausalito Municipal Code.

Other Sausalito zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Sausalito's PR zone?

32 feet — Sausalito Municipal Code § 10.22.040.

What is the minimum front setback in Sausalito's PR zone?

0 feet (10 ft where designated on the zoning map) — Sausalito Municipal Code § 10.22.040.

What is the minimum side setback in Sausalito's PR zone?

5 feet — Sausalito Municipal Code § 10.22.040.

What is the minimum rear setback in Sausalito's PR zone?

15 feet — Sausalito Municipal Code § 10.22.040.

What is the minimum lot size in Sausalito's PR zone?

20,000 sf — Sausalito Municipal Code § 10.22.040.

General information, not legal advice.

Ask about a Sausalito property in PR

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Sausalito