Skip to content

Sausalito · Zoning · W

Sausalito W zoning: height, setbacks and lot size

In Sausalito's W zone, buildings can be up to 32 ft tall and the minimum lot size is 25,000 sf (Sausalito code, read October 2026).

Key points

  • Maximum building height: 32 ft
  • Minimum lot size: 25,000 sf
  • Maximum lot coverage: 30%
  • Maximum floor area ratio (FAR): 0.30
  • Maximum density: 10% of total berths (liveaboard residential uses)

W is a zoning district in Sausalito. Every value below was read from the Sausalito Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in W

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
32 ft
§ 10.24.050 · code text
Table row “Maximum building height”, column “W”: 32 feet
Minimum lot size
25,000 sf
§ 10.24.050 · code text
Table row “Minimum parcel size”, column “W”: 25,000 sf
Maximum lot coverage
30%
§ 10.24.050 · code text
Table row “Maximum building coverage”, column “W”: 30%
Maximum floor area ratio (FAR)
0.30
See note 5 below the table in the code.
§ 10.24.050 · code text
Table row “Maximum floor area ratio (5)”, column “W”: .30
Note 5: Pursuant to Cal. Gov’t. Code § 65913.11(b), a housing development project consisting of three to seven units shall be allowed to have a floor area ratio of up to 1.0, and for a housing development project consisting of eight to 10 units, the project shall be allowed a floor area ratio of up to 1.25, except for projects within a historic district or property included on the State Historic Resources
Maximum density
10% of total berths
Applies: liveaboard residential uses
See note 1 below the table in the code.
§ 10.24.050 · code text
Table row “Maximum density 1 du per”, column “W”: 10% of total berths (1)
Note 1: Density allowed for liveaboard residential uses.

When a different number applies

The code sets other values for particular lots, buildings or locations in W:

  • Minimum rear setback: 15 ft — only when adjacent to residential zoning district § 10.24.050

Not on this page

We did not find a general stories, front setback, side setback, rear setback limit for W in the zoning tables we read. The code may still set one elsewhere — check the Sausalito Municipal Code.

Other Sausalito zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Sausalito's W zone?

32 ft — Sausalito Municipal Code § 10.24.050.

What is the minimum lot size in Sausalito's W zone?

25,000 sf — Sausalito Municipal Code § 10.24.050.

What is the maximum lot coverage in Sausalito's W zone?

30% — Sausalito Municipal Code § 10.24.050.

What is the maximum floor area ratio (far) in Sausalito's W zone?

0.30 — Sausalito Municipal Code § 10.24.050.

What is the maximum density in Sausalito's W zone?

10% of total berths (liveaboard residential uses) — Sausalito Municipal Code § 10.24.050.

General information, not legal advice.

Ask about a Sausalito property in W

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Sausalito