Appendix N — REPLICABLE BUILDINGS
N104 Replicable Design Submittal Requirements — 2025 California Building Code
California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Building Code (Title 24, Part 2) § N104 · Effective January 1, 2026 · Official source: Building Standards Commission
N104.1 General.¶
A summary description of the replicable design and related construction documents shall be submitted to an approved agency. Where approval is requested for elements of the replicable design that is not within the scope of the California Building Code, the construction documents shall specifically designate the codes for which review is sought. Construction documents shall be signed, sealed and dated by a registered design professional.
N104.1.1 Architectural plans and specifications. Where approval of the architectural requirements of the replicable design is sought, the submittal documents shall include architectural plans and specifications as follows:
Description of uses and the proposed occupancy groups for all portions of the building.
Proposed type of construction of the building.
Fully dimensioned drawings to determine building areas and height.
Adequate details and dimensions to evaluate means of egress, including occupant loads for each floor, exit arrangement and sizes, corridors, doors and stairs.
Exit signs and means of egress lighting, including power supply.
Accessibility scoping provisions.
Description and details of proposed special occupancies such as a covered mall, high-rise, mezzanine, atrium and public
garage. 8. Adequate details to evaluate fire-resistance-rated construction requirements, including data substantiating required ratings. 9. Details for plastics, insulation and safety glazing installation. 10. Details of required fire protection systems. 11. Material specifications demonstrating fire-resistance criteria.
N104.1.2 Structural plans, specifications and engineering details. Where approval of the structural requirements of the replicable design is sought, the submittal documents shall include details for each wind region, seismic design category and climate zone for which approval is sought; and shall include the following:
Signed and sealed structural design calculations that support the member sizes on the drawings.
Design load criteria, including: frost depth, live loads, snow loads, wind loads, earthquake design date and other special loads.
Details of foundations and superstructure.
Provisions for special inspections.
N104.1.3 Energy conservation details. Where approval of the energy conservation requirements of the replicable design is sought, the submittal documents shall include details for each climate zone for which approval is sought; and shall include the following:
- Climate zones for which approval is sought.
- Building envelope details.
- Building mechanical system details.
- Details of electrical power and lighting systems.
- Provisions for system commissioning.