11B-205 Operable Parts — 2025 California Building Code
California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Building Code (Title 24, Part 2) § 11B-205 · Effective January 1, 2026 · Official source: Building Standards Commission
11B- 205.1 General. Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with Section 11B- 309 .
Exceptions:
Operable parts that are intended for use only by service or maintenance personnel shall not be required to comply with Section 11B- 309 .
Electrical or communication receptacles serving a dedicated use shall not be required to comply with Section 11B- 309 .
Reserved.
Floor electrical receptacles shall not be required to comply with Section 11B- 309 .
HVAC diffusers shall not be required to comply with Section 11B- 309 .
Except for light switches, where redundant controls are provided for a single element, one control in each space shall not be required to comply with Section 11B- 309 .
Cleats and other boat securement devices shall not be required to comply with Section 11B- 309.3.
Exercise machines and exercise equipment shall not be required to comply with Section 11B- 309 . 9. In residential dwelling units with mobility features where receptacles are provided in a kitchen at a corner work surface, one receptacle shall be located 36 inches (915 mm) from either wall at the inside corner.
FIGURE 11B-205.1 Ex. 9—ELECTRICAL RECEPTACLES AT CORNER WORKSURFACES