1906 Footings for Light-Frame Construction — 2025 California Building Code
California Building Code (Title 24, Part 2) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Building Code (Title 24, Part 2) § 1906 · Effective January 1, 2026 · Official source: Building Standards Commission
[OSHPD 1R, 2 & 5] Plain concrete footings not permitted by OSHPD.
1906.1 Plain concrete footings.¶
For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required thickness of plain concrete footings is permitted to be 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm) on either side of the supported wall.