3138B.1 Aeration system.

A spa pool aeration and/or jet system shall be completely separate from the recirculation system and shall not be interconnected with any other pool.

Exceptions & meaning →

3138B.2 Maximum operating temperature.

The allowable water temperature of a spa pool shall not exceed 104° F (40° C).

Exceptions & meaning →

3138B.3 Surface area.

The water surface area of a spa pool shall not exceed 250 square feet (23.23 m [2] ).

Exceptions & meaning →

3138B.4 Maximum depth.

The water depth in a spa pool shall not exceed 4 feet (1220 mm).

Exceptions & meaning →

3138B.5 Emergency shut off switch.

A clearly labeled emergency shut off switch for the control of both the recirculation system and the aeration and/or jet system shall be installed adjacent to the spa pool.

Exceptions & meaning →

Get a plain-English answer with a citation back to this text.

Ask AI about this code
▸Contents — California Building Code (Title 24, Part 2)

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.