SEC. 99.12.101. SCOPE.¶
(Amended by Ord. No. 188,797, Eff. 12/31/25.)
Appendix A5 of the California Green Building Standards Code (CALGreen) is adopted by reference with the following exceptions: CALGreen Sections A5.105.1.1, A5.105.1.2, A5.106.4.3, A5.106.6.1, A5.106.11.1, A5.303.2.3.1, A5.303.2.3.2, A5.303.2.3.3, A5.303.2.3.4, A5.406.1, and Tables A5.106.4.3 A5.106.11.2.2, A5.106.11.2.3, A5.406.1, A5.410.3, A5.601, and A5.602 are not adopted; and in lieu, Los Angeles Municipal Code Section 99.12.508 and Subsections A5.105.1.1, A5.105.1.2, A5.106.4.3, A5.106.6, A5.106.6.1, A5.106.11.1, A5.303.2.3.1, A5.303.2.3.2, A5.303.2.3.3, A5.303.2.3.4, A5.406.1, A5.410.3, and Tables A5.106.4.3, A5.106.11.2.2, A5.106.11.2.3, A5.601, and A5.602 are added or amended as provided in this article.
A5.105.1.1. Existing Building Structure. Maintain at least 75 percent of existing building structure (including structural floor and roof decking) and envelope (exterior skin and framing) based on surface area.
EXCEPTIONS:
Window assemblies and nonstructural roofing material.
Hazardous materials that are remediated as a part of the project.
A5.105.1.2. Existing Non-Structural Elements. Reuse existing interior nonstructural elements (interior walls, doors, floor coverings and ceiling systems) in at least 50% of the area of the completed building (including additions).
A5.106.4.3. Changing Rooms. (Amended by Ord. No. 185,587, Eff. 7/16/18.) Provide changing/shower facilities for tenant-occupants only in accordance with LAMC Table A5.106.4.3 or document arrangements with nearby changing/shower facilities.
Table A5.106.4.3
| Number of Tenant- Occupants | Shower/ |
2-Tier (12"x15"x72") Personal Effects Lockers Required |
|---|---|---|
| 0 - 10 | 1 unisex shower | 1 |
| 11 - 50 | 1 unisex shower | 2 |
| 51 - 100 | 1 unisex shower | 3 |
| 101 - 200 | 1 shower stall per gender | 4 |
| Over 200 | 1 shower stall per gender for each 200 additional tenant-occupants | One 2-tier locker for each 50 additional tenant-occupants |
Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates.
A5.106.6. Parking Capacity. Design parking capacity to meet but not exceed minimum local zoning requirements.
A5.106.6.1. Reduce Parking Capacity. With the approval of the enforcement authority, employ strategies to reduce on-site parking area by 20%.
Use of on street parking or compact spaces, illustrated on the site plan; or
Implementation and documentation of programs that encourage occupants to carpool, ride share or use alternate transportation.
Note: Strategies for programs may be obtained from local TMAs.
A5.106.11.1. Hardscape Alternatives [N]. (Added by Ord. No. 187,208, Eff. 11/5/21.) Use one or a combination of strategies below for 75% of site hardscape.
Provide shade (mature within 15 years of occupancy);
Use light colored materials with an initial solar reflectance value of at least .30 as determined in accordance with American Society for Testing and Materials (ASTM) Standards E 1918 or C 1549;
Use open-grid pavement system or pervious or permeable pavement system; or
Use solar panel arrays to create a canopy shade system.
TABLE A5.106.11.2.2 [BSC] TIER 1
| ROOF SLOPE | MINIMUM 3-YEAR AGED SOLAR REFLECTANCE | THERMAL EMITTANCE | 3-YEAR AGED SRI |
|---|---|---|---|
| ≤ 2 : 12 | 0.68 | 0.85 | 82 |
| > 2 : 12 | 0.28 | 0.85 | 27 |
TABLE A5.106.11.2.3 TIER 2
| ROOF SLOPE | MINIMUM 3-YEAR AGED SOLAR REFLECTANCE | THERMAL EMITTANCE | 3-YEAR AGED SRI |
|---|---|---|---|
| ≤ 2 : 12 | 0.70 | 0.85 | 85 |
| > 2 : 12 | 0.34 | 0.85 | 35 |
A5.303.2.3.1. Tier 1 - 12 Percent Savings. A schedule of plumbing fixtures and fixture fittings that will reduce the overall use of potable water within the building by 12% shall be provided. The reduction shall be based on the maximum allowable water use per plumbing fixture and fitting as required by the Los Angeles Building Standards Code in Article 1, Chapter IX of the LAMC.
A5.303.2.3.2. Tier 2 - 20 Percent Savings. A schedule of plumbing fixtures and fixture fittings that will reduce the overall use of potable water within the building by 20% shall be provided. A calculation demonstrating a 20% reduction in the building shall be provided. The reduction shall be based on the maximum allowable water use per plumbing fixture and fitting as required by the Los Angeles Municipal Code.
A5.303.2.3.3. 25 Percent Savings. A schedule of plumbing fixtures and fixture fittings that will reduce the overall use of potable water within the building by 25% shall be provided. A calculation demonstrating a 25% reduction in the building "water use baseline" shall be provided. The reduction shall be based on the maximum allowable water use per plumbing fixture and fitting as required by the Los Angeles Municipal Code.
A5.303.2.3.4. Nonpotable Water Systems for Indoor Water Use. Utilizing nonpotable water systems (such as captured rainwater, treated graywater, and recycled water) intended to supply water closets, urinals, and other allowed uses, may be used in the calculations demonstrating the 12%, 20%, or 25% reduction. The nonpotable water system shall comply with the current edition of the Los Angeles Plumbing Code at Article 4, Chapter IX of the LAMC.
A5.406.1. Choice of Materials. Compared to other products in a given product category, choose materials proven to be characterized by one or more of the following for a minimum of 5% of the total value, based on estimated cost of materials on the project.
A5.410.3. Commissioning. For new buildings under 10,000 square feet (929.03 m2) or for additions, building commissioning shall be included in the design and construction processes of the building project to verify that the building systems and components meet the owner's or owner representative's project requirements. Commissioning shall be performed in accordance with this section by trained personnel with experience on projects of comparable size and complexity. Commissioning requirements shall include:
- Owner's or owner representative's project requirements;
- Basis of design;
- Commissioning measures shown in the construction documents;
- Commissioning plan;
- Functional performance testing;
- Documentation and training;
- Commissioning report.
All building operating systems covered by California Code of Regulations Title 24, Part 6, as well as process equipment and controls and renewable energy systems shall be included in the scope of the commissioning requirements. (Amended by Ord. No. 185,587, Eff. 7/16/18.)
TABLE A5.601 NONRESIDENTIAL BUILDINGS: Green Building Standards Code Proposed Performance Approach
Note: This table is intended only as an aid in illustrating the nonresidential tier structure
(Refer to Checklists A5.602, A5.602.1, and A5.602.2 for CALGreen verification guidelines for Mandatory Checklist, Tier 1 Checklist, and Tier 2 Checklist.)
(Amended by Ord. No. 188,797, Eff. 12/31/25.)
{'{'}Click here for a printable PDF version of this table{'}'}
| CATEGORY | ENVIRONMENTAL PERFORMANCE GOAL | TIER 1 | TIER 2 |
|---|---|---|---|
| All | Minimum Mandatory (See Mandatory Checklist) | Meet all of the provisions of Chapter 5 (See Tier 1 Checklist) | Meet all of the provisions of Chapter 5 (See Tier 2 Checklist) |
| DIVISION 5.1 Planning and Design | Reuse of Existing Building | See Section A5.105.1 and Section A5.105.2 requirements | See Section A5.105.1 and Section A5.105.2 requirements |
| DIVISION 5.1 Planning and Design | Designated Parking for Fuel Efficient Vehicles - (Tier 1 and Tier 2 only) | Approx. 35% of total spaces | Approx. 50% of total spaces |
| DIVISION 5.1 Planning and Design | Electric Vehicle Charging | Approx. 30% of total spaces | Approx. 45% of total spaces |
| DIVISION 5.1 Planning and Design | Cool Roof to Reduce Heat Island Effect | Meet Table A5.106.11.2.2 | Meet Table A5.106.11.2.3 |
| DIVISION 5.1 Planning and Design | 1 additional Elective from Division A5.1 | 3 additional Electives from Division A5.1 | |
| DIVISION 5.2 Energy Efficiency | Energy Performance 2 | Outdoor lighting power 90% of Part 6 allowance | Outdoor lighting power 90% of Part 6 allowance |
| DIVISION 5.2 Energy Efficiency | If applicable, solar water-heating system with minimum solar savings fraction of 0.15 | If applicable, solar water-heating system with minimum solar savings fraction of 0.15 | |
| DIVISION 5.2 Energy Efficiency | Warehouse door seals | Warehouse door seals | |
| DIVISION 5.2 Energy Efficiency | Comply with day lighting requirements | Comply with day lighting requirements | |
| DIVISION 5.2 Energy Efficiency | Exhaust heat recovery | Exhaust heat recovery | |
| DIVISION 5.2 Energy Efficiency | Energy Budget 95% or 90% of Part 6 calculated value of allowance | Energy Budget 90% or 85% of Part 6 calculated value of allowance | |
| DIVISION 5.3 Water Efficiency and Conservation | Indoor Water Use | 12% Savings | 20% Savings |
| DIVISION 5.3 Water Efficiency and Conservation | 1 additional Elective from Division A5.3 | 3 additional Electives from Division A5.3 | |
| DIVISION 5.4 Material Conservation and Resource Efficiency 3 | Cradle-to-Grave Whole Building Life Cycle Assessment | See Section A5.409.1, Section A5.409.2 and Section A5.409.2.3 requirements | See Section A5.409.1, Section A5.409.2 and Section A5.409.2.3 requirements |
| DIVISION 5.4 Material Conservation and Resource Efficiency 3 | Product GWP Compliance – Prescriptive Path | See Section A5.409.1, Section A5.409.2 and Section A5.409.2.3 requirements | See Section A5.409.1, Section A5.409.2 and Section A5.409.2.3 requirements |
| DIVISION 5.4 Material Conservation and Resource Efficiency 3 | 1 additional Elective from Division A5.4 | 3 additional Electives from Division A5.4 | |
| Division 5.5 Environmental Quality | Low-VOC Resilient Flooring | 90% of flooring meets VOC limits | 100% of flooring meets VOC limits 1 |
| Division 5.5 Environmental Quality | Low-VOC Thermal Insulation | Comply with VOC limits | Install no-added formaldehyde insulation and comply with VOC limits |
| Division 5.5 Environmental Quality | 1 additional Elective from Division A5.5 | 3 additional Electives from Division A5.5 | |
| Additional Measures | 1 Additional Elective from any division | 3 Additional Electives from any division | |
| Approximate Total Measures | 15 | 25 |
Exception: Allowance may be permitted in Tier 2 for up to 5 percent specialty purpose flooring.
Solar water-heating system requirement for newly constructed restaurants as per A5.203.1.1.2.
Exceptions:
a. Buildings with a natural gas service water heater with a minimum of 95 percent thermal efficiency.
b. Buildings where greater than 75 percent of the total roof area has annual solar access that is less than 70 percent. Solar access is the ratio of solar insolation including shade to the solar insolation without shade. Shading from obstructions located on the roof or any other part of the building shall not be included in the determination of annual solar access.
- Life cycle assessment compliant with Section A5.409.4 in this code may be substituted for prescriptive measures from Division A5.4.
SEC. 99.12.508.¶
(Amended by Ord. No. 187,719, Eff. 1/23/23.)
Section A5.602 of the 2016 CALGreen Code is adopted with amendments to read as follows:
TABLE A5.602 CALGREEN VERIFICATION GUIDELINES MANDATORY MEASURES CHECKLIST
(Amended by Ord. No. 188,797, Eff. 12/31/25.)
{'{'}Click here for a printable PDF version of this table{'}'}
Application: This checklist shall be used for nonresidential projects that meet one of the following: new construction, building additions of 1,000 square feet or greater, or building alterations with a permit valuation of $200,000 or more pursuant to Section 301.3 AND do not trigger a Tier 1 or Tier 2 requirement:
Y = Yes (section has been selected and/or included)
N/A = Not Applicable (code section does not apply to the project – mainly used for additions and alterations)
O = Other (provide explanation)
[N] = New construction pursuant to Section 301.3
[A] = Additions and/or Alterations pursuant to Section 301.3
| CHAPTER 5 DIVISIONS | SECTION TITLE | CODE SECTION | Y | N/A | O | PLAN SHEET, SPEC, OR ATTACH REFERENCE | |
|---|---|---|---|---|---|---|---|
| DIVISION 5.1 Planning and Design | Mandatory | Deconstruction and reuse of existing structures, scope with exception | 5.105.1 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Reuse of existing building & verification of compliance with note | 5.105.2 and 5.105.2.1 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Storm water pollution prevention for projects that disturb less than 1 acre of land | 5.106.1 through 5.106.2 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Short-term bicycle parking (with exception) | 5.106.4.1.1 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Long-term bicycle parking | 5.106.4.1.2 through 5.106.4.1.5 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Electric vehicle charging [N] with Section 5.106.3.1, 5.106.5.3.2 and associated Table 5.106.5.3.1 OR Independently Power Allocation Method: Section 5.106. 5.3.6 and associated Table 5.106.5.3.6 | 5.106.5.3.1, 5.106.5.3.2, Table 5.106.5.3.1, 5.106.5.3.2.1, 5.106.5.3.2.2, 5.106.5.3.2.3, 5.106.5.3.2.4, 5.106.5.3.3, 5.106.5.3.4 and 5.106.5.3.5 OR 5.106.5.3.3, 5.106.5.3.4, 5.106.5.3.5, 5.106.5.3.6, Table 5.106.5.3.6, 5.106.5.3.6.1, 5.106.5.3.6.2 and 5.106.5.3.6.3 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Additions or Alterations to existing buildings or parking facilities [A] with Exceptions | 5.106.5.4 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Existing buildings or parking areas without previously installed EV capable infrastructure [A] | 5.106.5.4.1 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Existing buildings or parking areas without previously installed EV capable infrastructure [A] | 5.106.5.4.2 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Electric vehicle (EV) charging: medium-duty and heavy-duty [N] | 5.106.5.5 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Electric vehicle charging readiness requirements for warehouses, grocery stores, office buildings, and manufacturing facilities and retail stores with planned off-street loading spaces [N] | 5.106.5.5.1 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Table 5.106.5.5.1 | 5.106.5.5 and 5.106.5.5.1 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Light pollution reduction [N] (with exceptions, notes and table) | 5.106.8 through 5.106.8.2 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Grading and paving (exception for additions and alterations not altering the drainage path) | 5.106.10 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Heat island effect | 5.106.11 | ||||
| DIVISION 5.1 Planning and Design | Mandatory | Hardscape alternatives [N] | 5.106.11.1 | ||||
| Division 5.2 Energy Efficiency | Mandatory | Meet the minimum energy efficiency standard | 5.201.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Separate meters (new buildings or additions > 50,000 sf that consume more than 100 gal/ |
5.303.1.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Separate meters (for tenants in new buildings or additions that consume more than 1,000 gal/ |
5.303.1.2 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Water Reduction | 5.303.2 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Water closets shall not exceed 1.28 gallons per flush (gpf) | 5.303.3.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Wall-mounted urinals shall not exceed 0.125 gpf | 5.303.3.2.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Floor-mounted urinals shall not exceed 0.5 gpf | 5.303.3.2.2 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Single showerhead shall have maximum flow rate of 1.8 gpm (gallons per minute) at 80 psi | 5.303.3.3.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Multiple showerheads serving one shower shall have a combined flow rate of 1.8 gpm at 80 psi | 5.303.3.3.2 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Nonresidential lavatory faucets | 5.303.3.4.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Kitchen faucets | 5.303.3.4.2 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Wash fountains | 5.303.3.4.3 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Metering faucets | 5.303.3.4.4 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Metering faucets for wash fountains | 5.303.3.4.5 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Pre-rinse spray valve | 5.303.3.4.6 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Food waste disposers | 5.303.4.1 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Areas of additions or alterations | 5.303.5 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Standards for plumbing fixtures and fittings | 5.303.6 | ||||
| Division 5.3 Water Efficiency and Conservation | Mandatory | Outdoor potable water use in landscape areas (with notes) | 5.304.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Weather protection | 5.407.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Moisture control: sprinklers | 5.407.2.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Moisture control: exterior door protection | 5.407.2.2.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Moisture control: flashing | 5.407.2.2.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Construction waste management – comply with either: Sections 5.408.1.1, 5.408.1.2, 5.408.1.3 or more stringent local ordinance | 5.408.1.1, 5.408.1.2, 5.408.1.3 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Construction waste management: documentation | 5.408.1.4 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Universal waste [A] | 5.408.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Excavated soil and land clearing debris (100% reuse or recycle) | 5.408.3 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Life cycle assessment, scope, whole building life cycle assessment with notes, building components, reference study period, and verification of compliance | 5.409.1, 5.409.2, 5.409.2.1, 5.409.2.2 and 5.409.2.3 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Life cycle assessment, scope, product GWP compliance – prescriptive path, 5.409.3.1 with exception and exception equation, verification of compliance and product GWP limits table with footnotes | 5.409.1, 5.409.3, 5.409.3.1, 5.409.3.2 and Table 5.409.3 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Recycling by occupants (with exception) | 5.410.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Recycling by occupants: additions (with exception) | 5.410.1.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Recycling by occupants: sample ordinance | 5.410.1.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Commissioning new buildings ( ≥ 10,000 sf) [N] | 5.410.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Owner’s or owner representative’s Project Requirements (OPR) [N] | 5.410.2.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Basis of Design (BOD) [N] | 5.410.2.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Commissioning plan [N] | 5.410.2.3 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Functional performance testing [N] | 5.410.2.4 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Documentation and training [N] | 5.410.2.5 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Systems manual [N] | 5.410.2.5.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Systems operation training [N] | 5.410.2.5.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Commissioning report [N] | 5.410.2.6 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Testing and adjusting for new buildings < 10,000 sf or new systems that serve additions or alterations [A] | 5.410.4 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | System testing plan for renewable energy, landscape irrigation and water reuse [A] | 5.410.4.2 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Procedures for testing and adjusting | 5.410.4.3 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Procedures for HVAC balancing | 5.410.4.3.1 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Reporting for testing and adjusting | 5.410.4.4 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Operation and maintenance (O&M) manual | 5.410.4.5 | ||||
| Division 5.4 Material Conservation and Resource Efficiency | Mandatory | Inspection and reports | 5.410.4.5.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Fireplaces | 5.503.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Woodstoves | 5.503.1.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Temporary ventilation | 5.504.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Covering of ducts openings and protection of mechanical equipment during construction | 5.504.3 | ||||
| Division 5.5 Environmental Quality | Mandatory | Adhesives, sealants and caulks | 5.504.4.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Paints and coatings | 5.504.4.3 | ||||
| Division 5.5 Environmental Quality | Mandatory | Aerosol paints and coatings | 5.504.4.3.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Aerosol paints and coatings: verification | 5.504.4.3.2 | ||||
| Division 5.5 Environmental Quality | Mandatory | Carpet systems | 5.504.4.4 | ||||
| Division 5.5 Environmental Quality | Mandatory | Carpet cushion | 5.504.4.4.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Carpet adhesives per Table 5.504.4.1 | 5.504.4.4.2 | ||||
| Division 5.5 Environmental Quality | Mandatory | Composite wood products | 5.504.4.5 | ||||
| Division 5.5 Environmental Quality | Mandatory | Composite wood products: documentation | 5.504.4.5.3 | ||||
| Division 5.5 Environmental Quality | Mandatory | Resilient flooring systems | 5.504.4.6 | ||||
| Division 5.5 Environmental Quality | Mandatory | Resilient flooring: verification of compliance | 5.504.4.6.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Thermal insulation | 5.504.4.7 | ||||
| Division 5.5 Environmental Quality | Mandatory | Verification of compliance | 5.504.4.7.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Acoustical ceilings and wall panels | 5.504.4.8 | ||||
| Division 5.5 Environmental Quality | Mandatory | Verification of compliance | 5.504.4.8.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Filters (with exceptions) | 5.504.5.3 | ||||
| Division 5.5 Environmental Quality | Mandatory | Filters: labeling | 5.504.5.3.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Environmental tobacco smoke (ETS) control | 5.504.7 | ||||
| Division 5.5 Environmental Quality | Mandatory | Indoor moisture control | 5.505.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Outside air delivery | 5.506.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Carbon dioxide (CO 2 ) monitoring | 5.506.2 | ||||
| Division 5.5 Environmental Quality | Mandatory | Carbon dioxide ( CO 2 ) monitoring in classrooms | 5.506.3 | ||||
| Division 5.5 Environmental Quality | Mandatory | Acoustical control (with exception) | 5.507.4 | ||||
| Division 5.5 Environmental Quality | Mandatory | Exterior noise transmission, prescriptive method (with exceptions) | 5.507.4.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Noise exposure where noise contours are not readily available | 5.507.4.1.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Performance method | 5.507.4.2 | ||||
| Division 5.5 Environmental Quality | Mandatory | Site features | 5.507.4.2.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Documentation of compliance | 5.507.4.2.2 | ||||
| Division 5.5 Environmental Quality | Mandatory | Interior sound transmission (with note) | 5.507.4.3 | ||||
| Division 5.5 Environmental Quality | Mandatory | Ozone depletion and greenhouse gas reductions | 5.508.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Chlorofluorocarbons (CFCs) | 5.508.1.1 | ||||
| Division 5.5 Environmental Quality | Mandatory | Halons | 5.508.1.2 | ||||
| Division 5.5 Environmental Quality | Mandatory | Supermarket refrigerant leak reduction for retail food stores 8,000 square feet or more Sections 5.508.2 through 5.508.2.6.3 | 5.508.2 through 5.508.2.6.3 | ||||
| Division 5.5 Environmental Quality | END OF MANDATORY PROVISIONS | ||||||
| Documentation Author's / Responsible Designer's Declaration Statement __ Mandatory: I attest that this mandatory provisions checklist is accurate and complete. | |||||||
| Signature: | Signature: | Signature: | Signature: | Signature: | Signature: | Signature: | Signature: |
| Company: | Company: | Company: | Date: | Date: | Date: | Date: | Date: |
| Address: | Address: | Address: | License: | License: | License: | License: | License: |
| City/ |
City/ |
City/ |
Phone: | Phone: | Phone: | Phone: | Phone: |
Continue researching
Los Angeles sources →Los Angeles local, state and federal sources. Edit the document title or filters, then run your search.
Get a plain-English answer with a citation back to this text.
Ask AI about this code