Skip to content

Antioch · Zoning · R-35

Antioch R-35 zoning: height, setbacks and lot size

In Antioch's R-35 zone, buildings can be up to 45 ft tall and the minimum lot size is 20,000 sq ft (Antioch code, read October 2026).

Key points

  • Maximum building height: 45 ft
  • Minimum side setback: 5 ft (Interior side yard. Two-story single-family lots need one side yard of 10 feet, as do at least 25% of lots in a subdivision.)
  • Minimum rear setback: 10 ft (Where a multi-family dwelling abuts a lot zoned RR, RE, R4 or R6, the rear yard is 20 feet.)
  • Minimum lot size: 20,000 sq ft
  • Maximum lot coverage: 50%
  • Maximum density: 35 units per acre

R-35 is a zoning district in Antioch. Every value below was read from the Antioch Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-35

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 ft
§ 9-5.601 · code text
Table row “R-35”, column “Maximum Height Feet b”: 45
Minimum side setback
5 ft
Applies: Interior side yard. Two-story single-family lots need one side yard of 10 feet, as do at least 25% of lots in a subdivision.
§ 9-5.601 · code text
Table row “R-35”, column “Minimum Side Yard Required in Feet e”: 5 ft.
Minimum rear setback
10 ft
Applies: Where a multi-family dwelling abuts a lot zoned RR, RE, R4 or R6, the rear yard is 20 feet.
§ 9-5.601 · code text
Table row “R-35”, column “Minimum Rear Yard Required in Feet”: 10 ft. m
Minimum lot size
20,000 sq ft
§ 9-5.601 · code text
Table row “R-35”, column “Minimum Building Site Sq. Ft.”: 20,000
Maximum lot coverage
50%
§ 9-5.601 · code text
Table row “R-35”, column “Maximum Lot Coverage”: 50%
Maximum density
35 units per acre
§ 9-5.601 · code text
Table row “R-35”, column “Maximum Density Allowed Units Per Gross Developable Acre d”: 35 du/acre

Uses in R-35

Uses the code's use tables allow in R-35, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, front setback, FAR limit for R-35 in the zoning tables we read. The code may still set one elsewhere — check the Antioch Municipal Code.

Other Antioch zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Antioch's R-35 zone?

45 ft — Antioch Municipal Code § 9-5.601.

What is the minimum side setback in Antioch's R-35 zone?

5 ft (interior side yard. Two-story single-family lots need one side yard of 10 feet, as do at least 25% of lots in a subdivision) — Antioch Municipal Code § 9-5.601.

What is the minimum rear setback in Antioch's R-35 zone?

10 ft (where a multi-family dwelling abuts a lot zoned RR, RE, R4 or R6, the rear yard is 20 feet) — Antioch Municipal Code § 9-5.601.

What is the minimum lot size in Antioch's R-35 zone?

20,000 sq ft — Antioch Municipal Code § 9-5.601.

What is the maximum lot coverage in Antioch's R-35 zone?

50% — Antioch Municipal Code § 9-5.601.

General information, not legal advice.

Ask about an Antioch property in R-35

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Antioch