Skip to content

Antioch · Zoning · R-4

Antioch R-4 zoning: height, setbacks and lot size

In Antioch's R-4 zone, buildings can be up to 35 ft tall and the minimum lot size is 6,000 sq ft (Antioch code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum side setback: 5 ft (Interior side yard. Two-story single-family lots need one side yard of 10 feet, as do at least 25% of lots in a subdivision.)
  • Minimum rear setback: 20 ft
  • Minimum lot size: 6,000 sq ft
  • Maximum lot coverage: 40%
  • Maximum density: 4 units per acre

R-4 is a zoning district in Antioch. Every value below was read from the Antioch Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R-4

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 9-5.601 · code text
Table row “R-4”, column “Maximum Height Feet b”: 35
Minimum side setback
5 ft
Applies: Interior side yard. Two-story single-family lots need one side yard of 10 feet, as do at least 25% of lots in a subdivision.
§ 9-5.601 · code text
Table row “R-4”, column “Minimum Side Yard Required in Feet e”: 5 ft.
Minimum rear setback
20 ft
§ 9-5.601 · code text
Table row “R-4”, column “Minimum Rear Yard Required in Feet”: 20 ft.
Minimum lot size
6,000 sq ft
§ 9-5.601 · code text
Table row “R-4”, column “Minimum Building Site Sq. Ft.”: 6,000
Maximum lot coverage
40%
§ 9-5.601 · code text
Table row “R-4”, column “Maximum Lot Coverage”: 40%
Maximum density
4 units per acre
§ 9-5.601 · code text
Table row “R-4”, column “Maximum Density Allowed Units Per Gross Developable Acre d”: 4 du/acre

Uses in R-4

Uses the code's use tables allow in R-4, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, front setback, FAR limit for R-4 in the zoning tables we read. The code may still set one elsewhere — check the Antioch Municipal Code.

Other Antioch zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Antioch's R-4 zone?

35 ft — Antioch Municipal Code § 9-5.601.

What is the minimum side setback in Antioch's R-4 zone?

5 ft (interior side yard. Two-story single-family lots need one side yard of 10 feet, as do at least 25% of lots in a subdivision) — Antioch Municipal Code § 9-5.601.

What is the minimum rear setback in Antioch's R-4 zone?

20 ft — Antioch Municipal Code § 9-5.601.

What is the minimum lot size in Antioch's R-4 zone?

6,000 sq ft — Antioch Municipal Code § 9-5.601.

What is the maximum lot coverage in Antioch's R-4 zone?

40% — Antioch Municipal Code § 9-5.601.

General information, not legal advice.

Ask about an Antioch property in R-4

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Antioch