In Antioch's RTC zone, generally buildings can be up to 50 ft tall, the front setback is 0 ft and the minimum lot size is 2,500 sq ft, with the conditions listed below (Antioch code, read October 2026).

Key points

  • Maximum building height: 50 ft
  • Minimum front setback: 0 ft (On the property line, except outdoor dining or plaza setbacks (up to one-third of lot depth), courtyards, or a uniform facade setback.)
  • Minimum side setback: 0 ft
  • Minimum rear setback: 0 ft
  • Minimum lot size: 2,500 sq ft
  • Maximum lot coverage: 100%
  • Maximum density: 20 units per acre (Up to 45 per acre inside the area bounded by the railroad, I Street, Second Street and E Street, for mixed use with a use permit.)

RTC is a zoning district in Antioch. Every value below was read from the Antioch Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RTC

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 ft
§ 9-5.601 · code text
Table row “RTC j”, column “Maximum Height Feet b”: 50
Minimum front setback
0 ft
Applies: On the property line, except outdoor dining or plaza setbacks (up to one-third of lot depth), courtyards, or a uniform facade setback.
§ 9-5.601 · code text
Table row “RTC j”, column “Front Yard Minimum a, k”: 0 i
Minimum side setback
0 ft
§ 9-5.601 · code text
Table row “RTC j”, column “Minimum Side Yard Required in Feet e”: 0 ft.
Minimum rear setback
0 ft
§ 9-5.601 · code text
Table row “RTC j”, column “Minimum Rear Yard Required in Feet”: 0 ft.
Minimum lot size
2,500 sq ft
§ 9-5.601 · code text
Table row “RTC j”, column “Minimum Building Site Sq. Ft.”: 2,500
Maximum lot coverage
100%
§ 9-5.601 · code text
Table row “RTC j”, column “Maximum Lot Coverage”: 100%
Maximum density
20 units per acre
Applies: Up to 45 per acre inside the area bounded by the railroad, I Street, Second Street and E Street, for mixed use with a use permit.
§ 9-5.601 · code text
Table row “RTC j”, column “Maximum Density Allowed Units Per Gross Developable Acre d”: 20 h

Not on this page

We did not find a general stories, FAR limit for RTC in the zoning tables we read. The code may still set one elsewhere — check the Antioch Municipal Code.

Other Antioch zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Antioch's RTC zone?

50 ft — Antioch Municipal Code § 9-5.601.

What is the minimum front setback in Antioch's RTC zone?

0 ft (on the property line, except outdoor dining or plaza setbacks (up to one-third of lot depth), courtyards, or a uniform facade setback) — Antioch Municipal Code § 9-5.601.

What is the minimum side setback in Antioch's RTC zone?

0 ft — Antioch Municipal Code § 9-5.601.

What is the minimum rear setback in Antioch's RTC zone?

0 ft — Antioch Municipal Code § 9-5.601.

What is the minimum lot size in Antioch's RTC zone?

2,500 sq ft — Antioch Municipal Code § 9-5.601.

General information, not legal advice.

Ask about an Antioch property in RTC

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question