Skip to content

Indio · Zoning · CN-14

Indio CN-14 zoning: height, setbacks and lot size

In Indio's CN-14 zone, buildings can be up to 40 ft (3 stories) tall and the front setback is 10 ft (Indio code, read October 2026).

Key points

  • Maximum building height: 40 ft
  • Maximum number of stories: 3 stories
  • Minimum front setback: 10 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 10 ft (building site setback; the individual lot rear setback in the same table is 20 ft)
  • Maximum floor area ratio (FAR): 0.25 (Non-residential)
  • Maximum density: 14 units/acre

CN-14 is a zoning district in Indio. Every value below was read from the Indio Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in CN-14

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
40 ft
§ 2.03.03 · code text
Table row “Maximum Height (ft)/Stories (ft)”, column “CN-14”: 40/3 stories
Maximum number of stories
3 stories
§ 2.03.03 · code text
Table row “Maximum Height (ft)/Stories (ft)”, column “CN-14”: 40/3 stories
Minimum front setback
10 ft
§ 2.03.03 · code text
Table row “Front — Minimum”, column “CN-14”: 10
Minimum side setback
5 ft
§ 2.03.03 · code text
Table row “Interior Side — Minimum”, column “CN-14”: 5; 10 ft abutting residential zones
Minimum rear setback
10 ft
Applies: building site setback; the individual lot rear setback in the same table is 20 ft
§ 2.03.03 · code text
Table row “Rear — Minimum”, column “CN-14”: 10
Maximum floor area ratio (FAR)
0.25
Applies: Non-residential
§ 2.03.03 · code text
Table row “Non-Residential Maximum Floor Area Ratio”, column “CN-14”: 0.25
Maximum density
14 units/acre
§ 2.03.03 · code text
Table row “Maximum”, column “CN-14”: 14.0

Uses in CN-14

Uses the code's use tables allow in CN-14, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in CN-14:

  • Maximum building height: 45 ft — With architectural features § 2.03.03
  • Minimum side setback: 10 ft — Abutting residential zones § 2.03.03
  • Minimum lot size: 10,000 sq ft — Minimum development project site for new lots § 2.03.03

Not on this page

We did not find a general lot size, lot coverage limit for CN-14 in the zoning tables we read. The code may still set one elsewhere — check the Indio Municipal Code.

Other Indio zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Indio's CN-14 zone?

40 ft — Indio Municipal Code § 2.03.03.

What is the maximum number of stories in Indio's CN-14 zone?

3 stories — Indio Municipal Code § 2.03.03.

What is the minimum front setback in Indio's CN-14 zone?

10 ft — Indio Municipal Code § 2.03.03.

What is the minimum side setback in Indio's CN-14 zone?

5 ft — Indio Municipal Code § 2.03.03.

What is the minimum rear setback in Indio's CN-14 zone?

10 ft (building site setback; the individual lot rear setback in the same table is 20 ft) — Indio Municipal Code § 2.03.03.

General information, not legal advice.

Ask about an Indio property in CN-14

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Indio