Skip to content

Indio · Zoning · DET-3

Indio DET-3 zoning: height, setbacks and lot size

In Indio's DET-3 zone, buildings can be up to 25 ft (2 stories) tall, the front setback is 20 ft and the minimum lot size is 10,000 sq ft (Indio code, read October 2026).

Key points

  • Maximum building height: 25 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 20 ft
  • Minimum side setback: 15 ft
  • Minimum rear setback: 25 ft
  • Minimum lot size: 10,000 sq ft
  • Maximum lot coverage: 40%
  • Maximum density: 3.0 units/acre

DET-3 is a zoning district in Indio. Every value below was read from the Indio Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in DET-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
25 ft
§ 2.02.03 · code text
Table row “Maximum Height (ft) - Primary Building”, column “DET-3”: 25/2 stories
Maximum number of stories
2 stories
§ 2.02.03 · code text
Table row “Maximum Height (ft) - Primary Building”, column “DET-3”: 25/2 stories
Minimum front setback
20 ft
§ 2.02.03 · code text
Table row “Front (primary frontage)”, column “DET-3”: 20
Minimum side setback
15 ft
§ 2.02.03 · code text
Table row “Interior Side”, column “DET-3”: 15
Minimum rear setback
25 ft
§ 2.02.03 · code text
Table row “Rear”, column “DET-3”: 25
Minimum lot size
10,000 sq ft
§ 2.02.03 · code text
Table row “Minimum Lot Size (sf)”, column “DET-3”: 10,000
Maximum lot coverage
40%
§ 2.02.03 · code text
Table row “Maximum Lot Coverage (% of lot)”, column “DET-3”: 40
Maximum density
3.0 units/acre
§ 2.02.03 · code text
Table row “Maximum”, column “DET-3”: 3.0

Uses in DET-3

Uses the code's use tables allow in DET-3, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in DET-3:

  • Maximum building height: 35 ft — Primary building with architectural features § 2.02.03

Not on this page

We did not find a general FAR limit for DET-3 in the zoning tables we read. The code may still set one elsewhere — check the Indio Municipal Code.

Other Indio zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Indio's DET-3 zone?

25 ft — Indio Municipal Code § 2.02.03.

What is the maximum number of stories in Indio's DET-3 zone?

2 stories — Indio Municipal Code § 2.02.03.

What is the minimum front setback in Indio's DET-3 zone?

20 ft — Indio Municipal Code § 2.02.03.

What is the minimum side setback in Indio's DET-3 zone?

15 ft — Indio Municipal Code § 2.02.03.

What is the minimum rear setback in Indio's DET-3 zone?

25 ft — Indio Municipal Code § 2.02.03.

General information, not legal advice.

Ask about an Indio property in DET-3

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question