Skip to content

Porterville · Zoning · CN

Porterville CN zoning: height, setbacks and lot size

In Porterville's CN zone, generally buildings can be up to 35 ft tall, the front setback is 5 to 10 ft and the minimum lot size is 6,000 sq ft, with the conditions listed below (Porterville code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Minimum front setback: 5 to 10 ft (the code sets a range: at least 5 ft, at most 10 ft; the building must stand within this distance)
  • Minimum side setback: 0 ft
  • Minimum rear setback: 0 ft
  • Minimum lot size: 6,000 sq ft
  • Maximum floor area ratio (FAR): 0.30

CN (Commercial Neighborhood) is a zoning district in Porterville. Every value below was read from the Porterville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in CN

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 203.03 · code text
Table row “Maximum height (ft.)”, column “CN”: 35
Minimum front setback
5 to 10 ft
Applies: the code sets a range: at least 5 ft, at most 10 ft; the building must stand within this distance
§ 203.03 · code text
Table row “Front”, column “CN”: 5 min., 10 max.
Minimum side setback
0 ft
§ 203.03 · code text
Table row “Interior side”, column “CN”: 0
Minimum rear setback
0 ft
§ 203.03 · code text
Table row “Rear”, column “CN”: 0
Minimum lot size
6,000 sq ft
§ 203.03 · code text
Table row “Minimum lot area (sq. ft.)”, column “CN”: 6,000
Maximum floor area ratio (FAR)
0.30
§ 203.03 · code text
Table row “Maximum floor area ratio”, column “CN”: 0.30

Uses in CN

Uses the code's use tables allow in CN, or allow with a permit. Each links to its page with the code section.

Not on this page

We did not find a general stories, lot coverage, density limit for CN in the zoning tables we read. The code may still set one elsewhere — check the Porterville Municipal Code.

Other Porterville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Porterville's CN zone?

35 ft — Porterville Municipal Code § 203.03.

What is the minimum front setback in Porterville's CN zone?

5 to 10 ft (the code sets a range: at least 5 ft, at most 10 ft; the building must stand within this distance) — Porterville Municipal Code § 203.03.

What is the minimum side setback in Porterville's CN zone?

0 ft — Porterville Municipal Code § 203.03.

What is the minimum rear setback in Porterville's CN zone?

0 ft — Porterville Municipal Code § 203.03.

What is the minimum lot size in Porterville's CN zone?

6,000 sq ft — Porterville Municipal Code § 203.03.

General information, not legal advice.

Ask about a Porterville property in CN

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Porterville