Skip to content

Porterville · Zoning · RM-3

Porterville RM-3 zoning: height, setbacks and lot size

In Porterville's RM-3 zone, buildings can be up to 50 ft tall, the front setback is 15 ft and the minimum lot size is 6,000 sq. ft. (Porterville code, read October 2026).

Key points

  • Maximum building height: 50 ft
  • Minimum front setback: 15 ft
  • Minimum side setback: 5 ft
  • Minimum rear setback: 10 ft
  • Minimum lot size: 6,000 sq. ft.
  • Maximum lot coverage: 60%
  • Maximum density: 30.5 units/net acre

RM-3 is a zoning district in Porterville. Every value below was read from the Porterville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in RM-3

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
50 ft
§ 201.03 · code text
Table row “Maximum height (ft.)”, column “RM-3”: 50
Minimum front setback
15 ft
§ 201.03 · code text
Table row “Residence (front)”, column “RM-3”: 15
Minimum side setback
5 ft
§ 201.03 · code text
Table row “Interior side”, column “RM-3”: 5
Minimum rear setback
10 ft
§ 201.03 · code text
Table row “Rear”, column “RM-3”: 10
Minimum lot size
6,000 sq. ft.
§ 201.03 · code text
Table row “Minimum lot area (sq. ft.)”, column “RM-3”: 6,000
Maximum lot coverage
60%
§ 201.03 · code text
Table row “Maximum building coverage (% of lot)”, column “RM-3”: 60
Maximum density
30.5 units/net acre
§ 201.03 · code text
Table row “Maximum density (units/net acre)”, column “RM-3”: 30.5

Uses in RM-3

Uses the code's use tables allow in RM-3, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in RM-3:

  • Minimum side setback: 12 ft — reversed corner lot; street side yard § 201.03
  • Minimum rear setback: 15 ft — School, government or institutional building next to an RS district; not more than 5 ft required from a lot line next to an alley § 201.03

Not on this page

We did not find a general stories, FAR limit for RM-3 in the zoning tables we read. The code may still set one elsewhere — check the Porterville Municipal Code.

Other Porterville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Porterville's RM-3 zone?

50 ft — Porterville Municipal Code § 201.03.

What is the minimum front setback in Porterville's RM-3 zone?

15 ft — Porterville Municipal Code § 201.03.

What is the minimum side setback in Porterville's RM-3 zone?

5 ft — Porterville Municipal Code § 201.03.

What is the minimum rear setback in Porterville's RM-3 zone?

10 ft — Porterville Municipal Code § 201.03.

What is the minimum lot size in Porterville's RM-3 zone?

6,000 sq. ft. — Porterville Municipal Code § 201.03.

General information, not legal advice.

Ask about a Porterville property in RM-3

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Porterville