Victorville IPD zoning: height, setbacks and lot size

In Victorville's IPD zone, buildings can be up to 45 ft tall, the front setback is 30 ft and the minimum lot size is 20,000 sq ft (Victorville code, read October 2026).

Key points

  • Maximum building height: 45 ft
  • Minimum front setback: 30 ft
  • Minimum side setback: 10 ft
  • Minimum rear setback: 25 ft
  • Minimum lot size: 20,000 sq ft
  • Maximum lot coverage: 60%
  • Maximum floor area ratio (FAR): 1.0

IPD is a zoning district in Victorville. Every value below was read from the Victorville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in IPD

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
45 ft
§ 16-3.11.020 · code text
Table row “Maximum Building Height”, column “IPD”: 45
Minimum front setback
30 ft
§ 16-3.11.020 · code text
Table row “Front Yard Setback”, column “IPD”: 30
Minimum side setback
10 ft
§ 16-3.11.020 · code text
Table row “Interior side”, column “IPD”: 10
Minimum rear setback
25 ft
§ 16-3.11.020 · code text
Table row “Interior rear”, column “IPD”: 25
Minimum lot size
20,000 sq ft
§ 16-3.11.020 · code text
Table row “Minimum Net Lot Area”, column “IPD”: 20,000 sq ft
Maximum lot coverage
60%
§ 16-3.11.020 · code text
Table row “Maximum Lot Coverage”, column “IPD”: 60%
Maximum floor area ratio (FAR)
1.0
§ 16-3.11.020 · code text
Table row “Maximum Floor Area Ratio (FAR)”, column “IPD”: 1.0

When a different number applies

The code sets other values for particular lots, buildings or locations in IPD:

  • Minimum side setback: 20 ft — Street side § 16-3.11.020
  • Minimum rear setback: 20 ft — Rear yard along a street § 16-3.11.020
  • Minimum rear setback: 30 ft — Along any rear or side lot line that abuts a residential district not separated by a public right-of-way; required setback increased by 30 feet when building height exceeds 30 feet § 16-3.11.020

Not on this page

We did not find a general stories, density limit for IPD in the zoning tables we read. The code may still set one elsewhere — check the Victorville Municipal Code.

Other Victorville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Victorville's IPD zone?

45 ft — Victorville Municipal Code § 16-3.11.020.

What is the minimum front setback in Victorville's IPD zone?

30 ft — Victorville Municipal Code § 16-3.11.020.

What is the minimum side setback in Victorville's IPD zone?

10 ft — Victorville Municipal Code § 16-3.11.020.

What is the minimum rear setback in Victorville's IPD zone?

25 ft — Victorville Municipal Code § 16-3.11.020.

What is the minimum lot size in Victorville's IPD zone?

20,000 sq ft — Victorville Municipal Code § 16-3.11.020.

General information, not legal advice.

Ask about a Victorville property in IPD

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question