Skip to content

Victorville · Zoning · MU-2

Victorville MU-2 zoning: height, setbacks and lot size

In Victorville's MU-2 zone, generally buildings can be up to 55 ft tall, the front setback is 15 ft and the minimum lot size is 5 acres, with the conditions listed below (Victorville code, read October 2026).

Key points

  • Maximum building height: 55 ft
  • Minimum front setback: 15 ft (First Story living)
  • Minimum side setback: 5 ft (Interior side)
  • Minimum rear setback: 15 ft
  • Minimum lot size: 5 acres
  • Maximum lot coverage: 50% (Residential development)
  • Maximum floor area ratio (FAR): 1.0 (Non-residential)
  • Maximum density: Up to 30.0 units per gross acre

MU-2 is a zoning district in Victorville. Every value below was read from the Victorville Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in MU-2

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
55 ft
See note 4 below the table in the code.
§ 16-3.09.020 · code text
Table row “Maximum Height”, column “Building Requirements (in ft.)”: 55 (4)
Note 4: No principal building shall exceed a height of one story when located within one hundred feet of an existing single-family residence.
Minimum front setback
15 ft
Applies: First Story living
§ 16-3.09.020 · code text
Table row “First Story living”, column “Building Requirements (in ft.)”: 15
Minimum side setback
5 ft
Applies: Interior side
§ 16-3.09.020 · code text
Table row “Interior side”, column “Building Requirements (in ft.)”: 5
Minimum rear setback
15 ft
§ 16-3.09.020 · code text
Table row “Minimum Rear Yard Setback”, column “Building Requirements (in ft.)”: 15
Minimum lot size
5 acres
§ 16-3.09.020 · code text
Table row “Minimum Net Lot Area”, column “Project Requirements”: 5 acres
Maximum lot coverage
50%
Applies: Residential development
§ 16-3.09.020 · code text
Table row “Lot Coverage”, column “Project Requirements”: 50% (residential development)/60% (non-residential development)
Maximum floor area ratio (FAR)
1.0
Applies: Non-residential
§ 16-3.09.020 · code text
Table row “Non-Residential Maximum Floor Area Ratio (FAR)”, column “Project Requirements”: 1.0
Maximum density
Up to 30.0 units per gross acre
§ 16-3.09.020 · code text
Table row “Maximum Dwelling Unit Density (per gross acre)”, column “Project Requirements”: Up to 30.0

When a different number applies

The code sets other values for particular lots, buildings or locations in MU-2:

Not on this page

We did not find a general stories limit for MU-2 in the zoning tables we read. The code may still set one elsewhere — check the Victorville Municipal Code.

Other Victorville zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Victorville's MU-2 zone?

55 ft — Victorville Municipal Code § 16-3.09.020.

What is the minimum front setback in Victorville's MU-2 zone?

15 ft (first Story living) — Victorville Municipal Code § 16-3.09.020.

What is the minimum side setback in Victorville's MU-2 zone?

5 ft (interior side) — Victorville Municipal Code § 16-3.09.020.

What is the minimum rear setback in Victorville's MU-2 zone?

15 ft — Victorville Municipal Code § 16-3.09.020.

What is the minimum lot size in Victorville's MU-2 zone?

5 acres — Victorville Municipal Code § 16-3.09.020.

General information, not legal advice.

Ask about a Victorville property in MU-2

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Victorville