Skip to content

Westminster · Zoning · MU

Westminster MU zoning: height, setbacks and lot size

In Westminster's MU zone, generally buildings can be up to 95 feet (6 stories) tall, the front setback is 5 ft and the minimum lot size is No minimum, with the conditions listed below (Westminster code, read October 2026).

Key points

  • Maximum building height: 95 feet (Mixed-use development (residential and nonresidential component))
  • Maximum number of stories: 6 stories (Mixed-use development (residential and nonresidential component))
  • Minimum front setback: 5 ft (ground floor; build-to line: the building must stand no more than 15 ft back)
  • Minimum side setback: None required
  • Minimum rear setback: 10 ft
  • Minimum lot size: No minimum
  • Maximum floor area ratio (FAR): 1.0 (Nonresidential development)
  • Maximum density: 50 du/ac (Site size under 2 acres)

MU (Mixed-Use Zone) is a zoning district in Westminster. Every value below was read from the Westminster Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in MU

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
95 feet
Applies: Mixed-use development (residential and nonresidential component)
§ 17.260.015 · code text
Table row “Mixed-use development (residential and nonresidential component)”, column “MU Zone”: 6 stories not to exceed 95 feet
Maximum number of stories
6 stories
Applies: Mixed-use development (residential and nonresidential component)
§ 17.260.015 · code text
Table row “Mixed-use development (residential and nonresidential component)”, column “MU Zone”: 6 stories not to exceed 95 feet
Minimum front setback
5 ft
Applies: ground floor; build-to line: the building must stand no more than 15 ft back
§ 17.260.015 · code text
Table row “Front, ground floor *”, column “MU Zone”: Minimum: 5 feet Maximum: 15 feet*
Minimum side setback
None required
§ 17.260.015 · code text
Table row “Side, interior lot”, column “MU Zone”: None required
Minimum rear setback
10 ft
§ 17.260.015 · code text
Table row “Rear”, column “MU Zone”: Minimum: 10 feet
Minimum lot size
No minimum
§ 17.260.015 · code text
Table row “Minimum lot size”, column “MU Zone”: No minimum
Maximum floor area ratio (FAR)
1.0
Applies: Nonresidential development
§ 17.260.015 · code text
Table row “Maximum nonresidential floor area ratio (FAR)”, column “MU Zone”: 1.0
Maximum density
50 du/ac
Applies: Site size under 2 acres
§ 17.260.015 · code text
Table row “Maximum residential density”, column “MU Zone”: Site size: Under 2 acres: 50 du/ac 2-3 acres: 70 du/ac 3+ acres: 90 du/ac Additional residential density may be permitted pursuant to § 17.260.015(C) .

Uses in MU

Uses the code's use tables allow in MU, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in MU:

  • Maximum building height: 75 feet — All other types of development § 17.260.015
  • Minimum side setback: 5 ft — street side of a corner lot; build-to line: the building must stand within 15 ft § 17.260.015
  • Maximum density: 70 du/ac — Site size 2–3 acres § 17.260.015
  • Maximum density: 90 du/ac — Site size 3+ acres § 17.260.015
  • Maximum density: Up to an additional 10 du/ac above the applicable base maximum residential density — Mixed-use development eligible under the Nonresidential Space Development Incentive, provided the project incorporates the required qualifying nonresidential area § 17.260.015

Not on this page

We did not find a general lot coverage limit for MU in the zoning tables we read. The code may still set one elsewhere — check the Westminster Municipal Code.

Other Westminster zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Westminster's MU zone?

95 feet (mixed-use development (residential and nonresidential component)) — Westminster Municipal Code § 17.260.015.

What is the maximum number of stories in Westminster's MU zone?

6 stories (mixed-use development (residential and nonresidential component)) — Westminster Municipal Code § 17.260.015.

What is the minimum front setback in Westminster's MU zone?

5 ft (ground floor; build-to line: the building must stand no more than 15 ft back) — Westminster Municipal Code § 17.260.015.

What is the minimum side setback in Westminster's MU zone?

None required — Westminster Municipal Code § 17.260.015.

What is the minimum rear setback in Westminster's MU zone?

10 ft — Westminster Municipal Code § 17.260.015.

General information, not legal advice.

Ask about a Westminster property in MU

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Westminster