Skip to content

Westminster · Zoning · R1

Westminster R1 zoning: height, setbacks and lot size

In Westminster's R1 zone, generally buildings can be up to 35 ft (2 stories) tall and the front setback is 50 ft from street centerline or 20 ft from ultimate right-of-way line, whichever is less, with the conditions listed below (Westminster code, read October 2026).

Key points

  • Maximum building height: 35 ft
  • Maximum number of stories: 2 stories
  • Minimum front setback: 50 ft from street centerline or 20 ft from ultimate right-of-way line, whichever is less (may be reduced to 10 ft if two cars can park in front of the garage (not cul-de-sac or knuckle lots); wide streets differ)
  • Minimum side setback: 5 ft (interior side; lots under 50 ft average width may use 10% of that width, at least 3 ft (older lots only))
  • Minimum rear setback: 20 ft or 20% of average lot depth, whichever is less (single-story portion (max 16 ft pitched roof, 11 ft flat) may use 10 ft with 1,000 sq ft of open back yard)
  • Maximum lot coverage: 40% (required covered or enclosed parking (up to 600 sq ft) does not count)
  • Maximum density: 1 unit per lot

R1 is a zoning district in Westminster. Every value below was read from the Westminster Municipal Code and links to its section (read October 2026). State laws such as the ADU and SB 9 rules can allow more on a residential lot. General information, not legal advice — read the code text and check with the city before you build.

Development standards in R1

The general rule for a typical lot in this zone. Zoning tables often attach notes, such as rules for corner lots, lots next to a residential zone, or new subdivisions only. Open “code text” under a value to see the table cell or sentence it was read from.

Maximum building height
35 ft
§ 17.210.015 · code text
Table row “Maximum building height:”, column “R1”: 2 stories not to exceed 35 feet For height limit exceptions, see Section 17.300.025
Maximum number of stories
2 stories
§ 17.210.015 · code text
Table row “Maximum building height:”, column “R1”: 2 stories not to exceed 35 feet For height limit exceptions, see Section 17.300.025
Minimum front setback
50 ft from street centerline or 20 ft from ultimate right-of-way line, whichever is less
Applies: may be reduced to 10 ft if two cars can park in front of the garage (not cul-de-sac or knuckle lots); wide streets differ
§ 17.210.015 · code text
Table row “Front yard”, column “R1”: Minimum 50 feet from the centerline of the street or highway upon which the building site fronts, or 20 feet from the ultimate right-of-way line, whichever is less 1, 11
Minimum side setback
5 ft
Applies: interior side; lots under 50 ft average width may use 10% of that width, at least 3 ft (older lots only)
§ 17.210.015 · code text
Table row “Side yard”, column “R1”: Minimum 5 9 feet; except, a corner lot shall have a street side yard of not less than 10 feet
Minimum rear setback
20 ft or 20% of average lot depth, whichever is less
Applies: single-story portion (max 16 ft pitched roof, 11 ft flat) may use 10 ft with 1,000 sq ft of open back yard
§ 17.210.015 · code text
Table row “Rear yard”, column “R1”: Minimum 20 feet or 20% of average lot depth, whichever is less 8
Maximum lot coverage
40%
Applies: required covered or enclosed parking (up to 600 sq ft) does not count
§ 17.210.015 · code text
Table row “Maximum lot coverage”, column “R1”: 40% 7
Maximum density
1 unit per lot
§ 17.210.015 · code text
Table row “Maximum Density”, column “R1”: 1 unit per lot

Uses in R1

Uses the code's use tables allow in R1, or allow with a permit. Each links to its page with the code section.

When a different number applies

The code sets other values for particular lots, buildings or locations in R1:

  • Minimum side setback: 10 ft — corner lot street side yard § 17.210.015
  • Minimum lot size: 6,000 sq ft — all other lots; corner lots require 6,500 sq ft § 17.210.015
  • Minimum lot size: 6,500 sq ft — corner lots § 17.210.015

Not on this page

We did not find a general lot size, FAR limit for R1 in the zoning tables we read. The code may still set one elsewhere — check the Westminster Municipal Code.

Other Westminster zoning districts

Who this affects

HomeownersArchitects and designersDevelopersReal estate agents

Frequently asked questions

What is the maximum building height in Westminster's R1 zone?

35 ft — Westminster Municipal Code § 17.210.015.

What is the maximum number of stories in Westminster's R1 zone?

2 stories — Westminster Municipal Code § 17.210.015.

What is the minimum front setback in Westminster's R1 zone?

50 ft from street centerline or 20 ft from ultimate right-of-way line, whichever is less (may be reduced to 10 ft if two cars can park in front of the garage (not cul-de-sac or knuckle lots); wide streets differ) — Westminster Municipal Code § 17.210.015.

What is the minimum side setback in Westminster's R1 zone?

5 ft (interior side; lots under 50 ft average width may use 10% of that width, at least 3 ft (older lots only)) — Westminster Municipal Code § 17.210.015.

What is the minimum rear setback in Westminster's R1 zone?

20 ft or 20% of average lot depth, whichever is less (single-story portion (max 16 ft pitched roof, 11 ft flat) may use 10 ft with 1,000 sq ft of open back yard) — Westminster Municipal Code § 17.210.015.

General information, not legal advice.

Ask about a Westminster property in R1

Ask GoCodebook what you can build at a specific address and get an answer that cites the section.

Ask your question

More on Westminster