Ch. 1 General Code Provisions — 2025 California Plumbing Code
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Sections in this part
- 1.1.1 Title.
- 1.1.2 Purpose.
- 1.1.3 Scope.
- 1.1.4 Appendices.
- 1.1.5 Referenced Codes.
- 1.1.6 Non-Building Standards, Orders, and Regulations.
- 1.1.7 Order of Precedence and Use.
- 1.1.8 City, County, or City and County Amendments, Additions or Deletions.
- 1.1.9 Effective Date of this Code.
- 1.1.10 Availability of Codes.
- 1.1.11 Format.
- 1.1.12 Validity.
- 1.2.1 BSC.
- 1.2.2 BSC-CG.
- 1.2.3 Alternate Materials, Design, and Methods of Construction and Equipment.
- 1.3.1 Specific scope of application of the agency responsible
- 1.3.2 Adopting Agency Identification.
- 1.4.1 Specific scope of application of the agency responsible
- 1.4.2 Adopting Agency Identification.
- 1.6.1 Specific scope of application of the agency responsible
- 1.6.2 Adopting Agency Identification.
- 1.7.1 Specific scope of application of the agency responsible
- 1.7.2 Adopting Agency Identification.
- 1.8.1 Purpose.
- 1.8.2 Authority and Abbreviations.
- 1.8.3 Local Enforcing Agency.
- 1.8.4 Permits, Fees, Applications, and Inspections.
- 1.8.5 Right of Entry for Enforcement.
- 1.8.6 Local Modification by Ordinance or Regulation.
- 1.8.7 Alternate Materials, Designs, Tests, and Methods of Construction.
- 1.8.8 Appeals Board.
- 1.8.9 Unsafe Buildings or Structures.
- 1.8.10 Other Building Regulations.
- 1.9.1 Division of the State Architect – Access Compliance.
- 1.9.2 Division of the State Architect – Structural Safety.
- 1.10.1 OSHPD 1 and OSHPD 1R.
- 1.10.2 OSHPD 2.
- 1.10.3 OSHPD 3.
- 1.10.4 OSHPD 4.
- 1.10.5 OSHPD 5.
- 1.10.6 OSHPD 6.
- 1.11.1 SFM-Office of the State Fire Marshal.
- 1.11.2 Duties and Powers of the Enforcing Agency.
- 1.11.3 Construction Documents.
- 1.11.4 Fees.
- 1.11.5 Inspections.
- 1.11.6 Certificate of Occupancy.
- 1.11.7 Temporary Structures and Uses.
- 1.11.8 Service Utilities.
- 1.11.9 Stop Work Order.
- 1.11.10 Unsafe Buildings, Structures, and Equipment.
- 1.11.11 Adopting Agency Identification.
- 1.13.1 Application
- 1.13.2 Adopting Agency Identification.
- 101.1 Title.
- 101.2 Scope.
- 101.3 Purpose.
- 101.4 Unconstitutional.
- 101.5 Validity.
- 102.1 Conflicts Between Codes.
- 102.2 Existing Installations.
- 102.3 Maintenance.
- 102.4 Additions, Alterations, Renovations, or Repairs.
- 102.5 Health and Safety.
- 102.6 Changes in Building Occupancy.
- 102.7 Moved Structures.
- 102.8 Appendices.
- 103.1 General.
- 103.2 Liability.
- 103.3 Applications and Permits.
- 103.4 Right of Entry.
- 104.1 Permits Required.
- 104.2 Exempt Work.
- 104.3 Application for Permit.
- 104.4 Permit Issuance.
- 104.5 Fees.
- 105.1 General.
- 105.2 Required Inspections.
- 105.3 Testing of Systems.
- 105.4 Connection to Service Utilities.
- 106.1 General.
- 106.2 Notices of Correction or Violation.
- 106.3 Penalties.
- 106.4 Stop Orders.
- 106.5 Authority to Disconnect Utilities in Emergencies.
- 106.6 Authority to Condemn.
- 107.1 General.
- 107.2 Limitations of Authority.
Cite as: 2025 California Plumbing Code (Title 24, Part 5) Chapter 1 · Effective January 1, 2026 · Official source: Building Standards Commission
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
| Adopting Agency | BSC | BSC-CG | SFM | HCD 1 | HCD 2 | HCD 1-AC | DSA AC | DSA SS | DSA SS/CC | OSHPD 1 | OSHPD 1R | OSHPD 2 | OSHPD 3 | OSHPD 4 | OSHPD 5 | OSHPD 6 | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopt Entire Chapter | X | |||||||||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) | S | A | M | P | L | E | ||||||||||||||||||
| Adopt only those sections that are listed below | ||||||||||||||||||||||||
| Chapter/ |
||||||||||||||||||||||||
| 202 |
Adopt the entire UPC chapter as amended, state-amended sections are listed below: If there is an “X” under a particular state agency’s acronym in this row, it means that a particular state agency has adopted the entire model code chapter, with state amendments.
Each section that a state agency has amended and/or added within a particular chapter is listed. There will be an “X” under an agency’s acronym in the row of the amended and/or added section.
Example:
CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE
CHAPTER 1 - GENERAL CODE PROVISIONS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE
CHAPTER 1 - GENERAL CODE PROVISIONS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
| Adopting Agency | BSC | BSC-CG | SFM | HCD 1 | HCD 2 | HCD 1-AC | DSA AC | DSA SS | DSA SS/CC | OSHPD 1 | OSHPD 1R | OSHPD 2 | OSHPD 3 | OSHPD 4 | OSHPD 5 | OSHPD 6 | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopt Entire Chapter | ||||||||||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) | X | X | S | A | M | P | L | E | ||||||||||||||||
| Adopt only those sections that are listed below | ||||||||||||||||||||||||
| Chapter/ |
||||||||||||||||||||||||
| 202 | X | X |
Adopt only those sections which are listed below: If there is an “X” under a particular state agency’s acronym in this row, it means that particular state agency is adopting only specific model code or state-amended sections within this chapter. There will be an “X” in the column under the agency’s acronym, as well as an “X” by each section that the agency has adopted.
Example:
CALIFORNIA PLUMBING CODE – MATRIX ADOPTION TABLE
CHAPTER 1 - GENERAL CODE PROVISIONS
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority and building application.)
| Adopting Agency | BSC | BSC-CG | SFM | HCD 1 | HCD 2 | HCD 1-AC | DSA AC | DSA SS | DSA SS/CC | OSHPD 1 | OSHPD 1R | OSHPD 2 | OSHPD 3 | OSHPD 4 | OSHPD 5 | OSHPD 6 | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopt Entire Chapter | ||||||||||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) | S | A | M | P | L | E | ||||||||||||||||||
| Adopt only those sections that are listed below | X | |||||||||||||||||||||||
| Chapter/ |
||||||||||||||||||||||||
| 101 | X | |||||||||||||||||||||||
| 202 | X |
HOW TO DISTINGUISH MODEL CODE LANGUAGE FROM CALIFORNIA AMENDMENTS
[BSC]
To distinguish between model code language and incorporated California Amendments, including exclusive California standards, California amendments will appear in italics font print.
Symbols in the margins indicate the status of code changes as follows:
This symbol identifies which State agency(s) by its “acronym” that has amended a section of the model code. For a complete listing of State agency acronyms, see the Application Section within Chapter 1, Division I.
This symbol indicates that a change has been made to a California amendment.
This symbol indicates that a section, paragraph, or table has been revised or relocated within IAPMO model code language.
This symbol indicates deletion of California language.
This symbol indicates where an entire section, paragraph, or table has been deleted from IAPMO model code language.
Revision Markings A double right angle ( « ) in the margin indicates that the text or a table has been relocated within the code.
TIA TIA indicates that the revision is the result of a Tentative Interim Amendment.
TIA TIA For further information on tentative interim amendments see Section 5 of the IAPMO TIA Regulations Governing Committee Projects available at http://codes.iapmo.org/
A reference in brackets [ ] following a section or paragraph indicates material that has been extracted from another document. This reprinted material is not the complete and official position of the source document on the referenced subject that is represented by the standard in its entirety. Material contained in this document that is taken or extracted from NFPA standards is used with permission of the National Fire Protection Association. This material is not the complete and official position of the NFPA on the reference subject, which is represented solely by the relevant standard in its entirety. NFPA standards can be accessed at www.nfpa.org. In addition, this extracted material may include revisions or modifications developed through IAPMO’s standards development process. Therefore, NFPA disclaims responsibility for the content of this Code.
Text that is extracted pursuant to IAPMO’s Extract Guidelines, but outside of the regular revision process is denoted with the use of the source document in the margin. This text is not fully processed by IAPMO in accordance with ANSI’s public announcement consensus requirements for an American National Standard (ANS) nor approved by ANSI’s Board of Standards Review. The next revision cycle processes such text in accordance with those requirements.
Important Notices and Disclaimers The 2024 edition of the Uniform Plumbing Code is developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on plumbing issues. While the International Association of Plumbing and Mechanical Officials (IAPMO) administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in its codes
and standards.
IAPMO disclaims liability for any personal injury, property, or other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, or reliance on this document. IAPMO also makes no guarantee or warranty as to the accuracy or completeness of any information published
herein.
In issuing and making this document available, IAPMO is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is IAPMO undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances.
Updating IAPMO Codes Users of IAPMO codes should be aware that IAPMO codes may be amended from time to time through the issuance of Tentative Interim Amendments or corrected by Errata. IAPMO codes consist of the current edition of the document together with any Tentative Interim Amendment and any Errata in effect.
To access information for a specific code or to determine whether an IAPMO code has been amended through the issuance of Tentative Interim Amendments or corrected by Errata, please visit the IAPMO codes information page on the IAPMO’s website (https://www.iapmo.org/codedevelopment). The codes information page provides a list of IAPMO codes with up-to-date, specific information including any issued Tentative Interim Amendments and Errata.
Origin and Development The advantages of a statewide adopted Uniform Plumbing Code are recognized throughout the industry. Disorder in the industry because of widely divergent plumbing practices and the use of many different, often conflicting, plumbing codes by local jurisdictions influenced the Western Plumbing Officials Association (now the International Association of Plumbing and Mechanical Officials [IAPMO]) to form a committee. This committee of plumbing inspectors, master and journeyman plumbers, and plumbing engineers, backed by public utility companies and the plumbing industry to create a basic plumbing document for general use. The product of this effort, the first edition of the Uniform Plumbing Code [®] (UPC [®] ) was adopted by IAPMO in 1945. The widespread use of this code over the past seven decades by jurisdictions throughout the United States and internationally is testament to its merit.
Publishing of the 2003 Uniform Plumbing Code was a significant milestone because it was the first time in the history of the United States a plumbing code was developed through a true consensus process. The 2024 edition represents the most current approaches in the plumbing field and is the eighth edition developed under the ANSI consensus process. Contributions to the content of this code consists of diverse interests as consumers, enforcing authorities, installers/maintainers, labor, manufacturers, research/standards/ testing laboratories, special experts, and users.
The Uniform Plumbing Code provides consumers with safe and sanitary plumbing systems while, at the same time, allowing latitude for innovation and new technologies. The public at large is invited and encouraged to take part in IAPMO’s open consensus code development process. This code is updated every three years. The Uniform Plumbing Code is dedicated to all those who, in working to achieve “the ultimate plumbing code,” have unselfishly devoted their time, effort, and personal funds to create and maintain this, the finest plumbing code in existence today.
The Uniform Plumbing Code updates every three years in revision cycles that begin twice each year that takes two years to complete.
Each revision cycle advances according to a published schedule that includes final dates for all major events and contains four basic steps as follows:
- Proposal Stage;
- Comment Stage;
- Association Technical Meeting;
- Council Appeals and Issuance of Code.
IAPMO develops “full consensus” codes built on a foundation of maximum participation and agreement by a broad range of interests. This philosophy has led to producing technically sound codes that promote health and safety, yet do not stifle design or development.
It is important to stress that the process remains committed to the principles of consensus code development where consensus Technical Committees and Correlating Committees revise codes. The public and membership are offered multiple opportunities to debate, provide input and raise concerns through Amending Motions at the annual Assembly Consideration Session. Anyone may submit an appeal related to the issuance of a document through the IAPMO Standards Council.
The 2024 Uniform Plumbing Code is supported by the ASSE International (ASSE), Mechanical Contractors Association of America (MCAA), the Plumbing-Heating-Cooling Contractors National Association (PHCC-NA), the United Association (UA), and the World Plumbing Council (WPC). The presence of these logos, while reflecting support, does not imply any ownership of the copyright to the UPC, which is held exclusively by IAPMO. Further, the logos of these associations indicate the support of IAPMO’s open consensus process being used to develop IAPMO’s codes and standards.
The addresses of the organizations are as follows: ASSE – 18927 Hickory Creek Drive, Suite 220 • Mokena, IL 60448 • (708) 995-3019 MCAA – 1385 Piccard Drive • Rockville, MD 20850 • (301) 869-5800 PCA – 1385 Piccard Drive • Rockville, MD 20850 • (301) 869-5800 PHCC-NA – 180 S Washington Street, Suite 100 • Falls Church, VA 22040-6808 • (800) 533-7694 UA – Three Park Place • Annapolis, MD 21401 • (410) 269-2000 WPC – Auf der Mauer 11 • 8021 Zurich, Switzerland • Secretariat@worldplumbing.org
Adoption The Uniform Plumbing Code is available for adoption and use by jurisdictions in the United States and Internationally. Its use within a governmental jurisdiction is accomplished through adoption by reference in accordance with applicable jurisdictional laws. At adoption, jurisdictions should insert the applicable information in bracketed words in the sample ordinance. The sample legislation for adoption of the Uniform Plumbing Code on page xx provides key components, regulations and resolutions.
Revision Markings
Solid vertical lines in the margins indicate a technical change from the requirements of the
2021 edition. An arrow ( ) in the margin indicates where an entire section, paragraph,
exception, figure, or table has been deleted, or an item in a list of items or a table has been
deleted.
A double right angle ( « ) in the margin indicates that the text, table, or figure has been relocated within the code. The table found on page xxii points out the relocations in the 2024 edition of the Uniform Plumbing Code .
TIA TIA indicates that the revision is the result of a Tentative Interim Amendment. TIA For further information on tentative interim amendments see Section 5 of the IAPMO TIA TIA Regulations Governing Committee Projects available at https://www.iapmo.org/code**TIA** development
A reference in brackets [ ] following a section or paragraph indicates material that has been extracted from another document. A reference in brackets { } following a section or paragraph indicates material that has been extracted from another document and has been modified further by the Technical Committee. This reprinted material is not the complete and official position of the source document on the referenced subject that is represented by the standard in its entirety. Material contained in this document that is taken or extracted from NFPA standards is used with permission of the National Fire Protection Association. This material is not the complete and official position of the NFPA on the reference subject, which is represented solely by the relevant standard in its entirety. NFPA standards can be accessed at www.nfpa.org. In addition, this extracted material may include revisions or modifications developed through IAPMO’s standards development process. Therefore, NFPA disclaims responsibility for the content of this code.
Text that is extracted pursuant to IAPMO’s Extract Guidelines, but outside of the regular revision process is denoted with the use of the source document in the margin. This text is not fully processed by IAPMO in accordance with ANSI’s public announcement consensus requirements for an American National Standard (ANS) nor approved by ANSI’s Board of Standards Review. The next revision cycle processes such text in accordance with those requirements.
The format of the Uniform Plumbing Code (UPC) arranges each chapter in accordance with a specific subject matter. However, Chapter 3 is dedicated to general requirements that are applicable to every chapter. The subject matters are divided as follows:
| CHAPTERS | SUBJECTS |
|---|---|
| 1 | Administration |
| 2 | Definitions |
| 3 | General Regulations |
| 4 | Plumbing Fixtures and Fixture Fittings |
| 5 | Water Heaters |
| 6 | Water Supply and Distribution |
| 7 | Sanitary Drainage |
| 8 | Indirect Wastes |
| 9 | Vents |
| 10 | Traps and Interceptors |
| 11 | Storm Drainage |
| 12 | Fuel Gas Piping |
| 13 | Health Care Facilities and Medical Gas and Medical Vacuum Systems |
| 14 | Firestop Protection |
| 15 | Alternate Water Sources for Nonpotable Applications |
| 16 | Nonpotable Rainwater Catchment Systems |
| 17 | Referenced Standards |
| Appendix A | Recommended Rules for Sizing the Water Supply System |
| Appendix B | Explanatory Notes on Combination Waste and Vent Systems |
| Appendix C | Alternate Plumbing Systems |
| Appendix D | Sizing Storm Water Drainage Systems |
| Appendix E | Manufactured/ |
| Appendix F | Firefighter Breathing Air Replenishment Systems |
| Appendix G | Sizing of Venting Systems |
| Appendix H | Private Sewage Disposal Systems |
| Appendix I | Installation Standards |
| Appendix J | Combination of Indoor and Outdoor Combustion and Ventilation Opening Design |
| Appendix K | Potable Rainwater Catchment Systems |
| Appendix L | Sustainable Practices |
| Appendix M | Peak Water Demand Calculator |
| Appendix N | Impact of Water Temperature on the Potential for Scalding and Legionella Growth |
| Appendix O | Non-Sewered Sanitation Systems |
| Appendix P | Professional Qualifications |
| Appendix Q | Indoor Horticultural Facilities |
| Appendix R | Tiny Houses |
| Appendix S | Onsite Stormwater Treatment Systems |
The following is a summary of the scope and intent of the provisions addressed within the chapters and appendices of the Uniform Plumbing Code :
Chapter 1 Administration.
Chapter 1 regulates the application, enforcement, and administration of subsequent requirements of the code. As well as establishing the scope of the code, this chapter is concerned with enforcing the requirements contained in the body of the code. A plumbing code, as with any other code, is intended to be adopted as a legally enforceable document to safeguard health, safety, property, and public welfare. The code cannot be effective without satisfactory provisions for its administration and enforcement. The Authority Having Jurisdiction is to review the proposed and completed work and to decide whether a plumbing system conforms to the code requirements. As a public servant, the Authority Having Jurisdiction enforces the code in an unbiased, proper manner. The design professional is responsible for the design of a safe plumbing system. The contractor is responsible for installing the system in accordance with the plans.
Chapter 2 Definitions.
To maintain consistency and encourage the use of common terminology, Chapter 2 establishes definitions to provide clarity of terms and promote the use of a common language throughout the code. Understanding definitions within the context of their application enables greater collaboration, efficiency, standardization, and interpretation in applying and enforcing terms used throughout the code. Codes are technical documents, and every term can impact the meaning of the code text. Terms not defined have a normally accepted meaning.
Chapter 3 General Regulations.
Chapter 3 regulates the general requirements, not specific to other chapters, for installing plumbing systems. Many regulations are not specific plumbing requirements but relate to the overall plumbing system. This chapter contains safety requirements for installing plumbing and also contains nonplumbing requirements for identifying pipes, pipe fittings, traps, fixtures, materials, and devices used in plumbing systems. Listing method of approval, based on applicable nationally recognized standards, for the safe and proper installation of plumbing systems, is essential to ensure the protection of public health, safety, and welfare. The safety requirements provide protection for piping, material, and structures, with provisions for installation practices, removing stress and strain of the pipe, sleeving, and hanger support. The building’s structural stability is protected by the regulations for cutting and notching of structural members.
Chapter 4 Plumbing Fixtures and Fixture Fittings.
This chapter regulates the minimum number of plumbing fixtures of a specific type and quality for each building. The fixtures must be properly installed to be usable by the individuals occupying the building. The quality and design of every fixture must conform to the applicable referenced standard. Compliance with this chapter will result in a building or structure having acceptable plumbing fixtures for the sanitary, hygienic, cleaning, washing, and food preparation needs of the occupants. In addition to ensuring resilient fixtures, the chapter also takes into consideration gender-neutral facilities and contains provisions for privacy compartments.
Chapter 5 Water Heaters.
Chapter 5 regulates the design, approval, installation, and safety devices of fuel burning and other types of water heaters with the combustion air requirements for ventilation and dilution of flue gases for appliances installed in buildings. This chapter does not apply to direct-vent appliances. In addition, this chapter regulates the design, construction, installation, and maintenance of chimneys, vents, and their connections to fuel-burning appliances. Methods to supply combustion air may be supplied from an indoor air supply, outdoor air supply, a combination of indoor and outdoor air supply, mechanical air supply, or an engineered system. Combustion air provisions are based on the number of openings and the total opening size required based on the total energy input rating of the appliance. An acceptable air supply for combustion and ventilation is necessary for the proper operation of fuel-burning appliances. A shortage of combustion air can result in incomplete combustion and the production of poisonous gases, such as carbon monoxide or appliance overheating. Ventilation air provides cooling for the appliance casing and internal controls. Inadequate ventilation of the space in which an appliance is installed can result in increased surrounding temperatures that stress the appliance itself or other appliances in the vicinity.
Chapter 6 Water Supply and Distribution.
Chapter 6 regulates the design, material, and installation of water supply and distribution systems, including residential fire sprinklers. The water supply and distribution system is designed to achieve the correct water pressure and flow rates and avoid cross-connections. For fixtures to perform properly, an acceptable supply of potable water is essential to their operation and use. Cross-connections and backflow are ranked as the highest priority because of the long history of recognized health risks posed by cross-connections, outbreaks, or cases of waterborne disease. Piping materials and components are evaluated for their possible effect on the potable water with which they are in contact. The intent is to control the potential adverse health effects produced by indirect additives, products, and materials that come in contact with potable water. When selecting materials for water supply and distribution systems, consider water pressure, water temperature, compatibility with the water supply, durability, support, and sustainability.
In addition, this chapter regulates the design, location, materials, and installation of multipurpose and stand-alone sprinkler systems that do not include the use of antifreeze. Where systems are installed as a portion of the water distribution system under the requirements of this chapter and are not provided with a fire department connection, backflow protection for the water supply system is not required.
Chapter 7 Sanitary Drainage.
This chapter regulates the design and installation of sanitary drainage systems to ensure they will work as intended. Drainage piping should not be oversized nor undersized, and constructed of approved materials to guard against fouling, deposit of solids, clogging, and with cleanouts so arranged that the pipes may be readily cleaned. The purpose of the sanitary drainage system is to remove effluent discharged from plumbing fixtures and other equipment to an approved point of disposal, such as a public sanitary system or private sewage disposal system.
The basics of a sanitary drainage system include public and private sewage disposal; selection of materials; installation of the building drain and sewer; joining methods for pipe and fittings; drainage fixture units for sizing the drainage system; sumps and ejectors; vent sizing and length of vents; and testing.
Chapter 8 Indirect Wastes.
Chapter 8 regulates indirect waste connections that are required for plumbing fixtures and plumbing appliances dealing with food preparation, dishwashing, potable liquids, and similar equipment. An indirect connection prevents sewage from backing up into a fixture or appliance, thus providing protection against potential health hazards. The waste pipe discharges through an air gap or air break into a waste receptor or standpipe. The protection in the form of an air gap is necessary when the contamination is a potential health hazard or cross connection with the potable water system. Where there is no possibility of contaminating the potable water (nonpotable discharge), the indirect waste pipe may connect in the form of an air break. This method is often preferred to prevent splashing. In addition, health care facilities and special wastes must be protected from contamination that may result from the connection to the drainage system. The waste must be treated to prevent any damage to the piping or sewage treatment process. Waste receptors are sized and designed to prevent splashing and allow for peak discharge conditions.
Chapter 9 Vents.
Chapter 9 regulates the material, design, and installation of vents. A vent system is a pipe or pipes installed in a drainage system that provide a flow of air to and from the system to ventilate it, provide a circulation of air to eliminate trap siphonage, and reduce back-pressure and vacuum surge. In addition, vents provide the rapid and silent flow of waste without exposing occupants of the building to any sewer gases. Proper installation of vents is crucial, as a telltale sign that there is a problem in the drain and vent system is related to the elevation of the horizontal portion of the venting. Venting is not limited to sanitary drainage systems. Venting methods are applicable to other drainage systems such as those for chemical waste, graywater waste, and clear water waste. Sizing the venting system is directly tied to the design of the drainage system. For example, the velocities in the drainage system and its peak flow rates affect the diameters in the venting system. Where the vertical distance between a fixture outlet and trap is excessive, velocities in the entire drainage system will be greater than those in the vent sizing table. All venting methods in this chapter are categorized as either dry vents or wet vents. Vent stacks, stack vents, branch vents, island vents, relief vents, and individual vents are dry vents. Wet vents (horizontal or vertical), circuit vents, combination drain and vents are versions of “wet venting” in which the vent is wetted by drainage flow.
Chapter 10 Traps and Interceptors.
Chapter 10 regulates the material, design, and installation of traps, interceptors, and separators. Traps are required on drainage type plumbing fixtures and must be self-scouring without interior partitions. Interceptors, on the other hand, are designed to control what goes down a drain. Interceptors are used to keep harmful substances from entering the sanitary drainage system, such as grease, sand, oil and other materials. The retained materials need periodic removal to maintain efficiency and function of the separating device. The capacity of an interceptor is based on retention and flow rate. There are many types of interceptors that are used at beauty salons, hospitals, meat, fish or foul packaging, refineries, repair garages, gas stations, car washing facilities, various plants, factories, and processing sites. The designer of the building is responsible for locating interceptors with the expectation for the frequency of maintenance, ease of cleaning and floor space for equipment.
Chapter 11 Storm Drainage.
Chapter 11 regulates the removal of stormwater from roofs, yards, paved areas, and similar areas. The objective of storm drainage systems is to provide a conduit or channel through which runoff will be carried from a point of collection to a point of disposal; this protects the property and the public from the uncontrolled flow of runoff and ensures that drains and inlets are adequately sized to receive the volume of runoff that flows to the drains. For the purpose of system design, it’s necessary to specify the duration of a selected storm. All methods used to determine volumes and peak flow use historical data. Drain location must be coordinated with the architectural design of the building. When selecting the type of roof drain to use, the roof construction and its thickness, along with the intended use of the roof, are required. Where the roof perimeter extends above the roof in such a manner that water is entrapped and causes ponding, or if any portion of the roof is designed so water can pond, secondary drainage is required. Where secondary drainage is required, scuppers, or a secondary system of roof drains and pipes, are installed to prevent the accumulation of excessive rainwater.
Chapter 12 Fuel Gas Piping.
Chapter 12 regulates the installation of gas piping in a building, structure or within the property lines of buildings up to 5 psi. Gas piping systems must supply the minimum volume of gas required by each gas appliance to perform their proper operation under working conditions without exceeding the maximum pressure specified by each manufacturer. Because of the hazards associated with fuel gas, it is important to ensure the gas system has been inspected and tested, and that it is safe to turn on the gas supply to the building.
Chapter 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems.
Chapter 13 regulates the installation, inspection, testing, maintenance, performance, and safe practices for medical gas and vacuum systems located in health care facilities. This chapter addresses the installation and maintenance of health care fixtures, devices, and equipment. The purpose of medical gas and medical vacuum systems is to provide safe and sufficient flows at required pressures to the medical gas outlet or vacuum inlet terminals. System design and layout should allow convenient access by the medical staff to outlet and inlet terminals, valves, and equipment during patient care or emergencies, as safety is of primary concern.
Chapter 14 Firestop Protection.
Chapter 14 regulates piping penetrations of fire-resistance-rated walls, partitions, floors, floor and ceiling assemblies, roof and ceiling assemblies, or shaft enclosures through firestopping. To firestop is to create a physical barrier that impedes the spread of smoke, gases, and flames from one compartment in the building design to the next. The firestop is seen as a part that is essential to protecting the lives of people who live or work in the structure, increasing the chances of not succumbing to smoke or gases before they are able to evacuate the building. Fireproofing of this type helps to restore the fire-resistant properties of the building materials before the openings were created as part of the construction process.
Chapter 15 Alternate Water Sources for Nonpotable Applications.
Chapter 15 regulates gray water sources, reclaimed (recycled) water sources and on-site treated nonpotable water systems. Water sources include subsurface irrigation, subsoil irrigation, and mulch basin systems. Subsoil water irrigation provides a means to disperse shallow drip irrigation lines and mulch basins that collect and spread water in various applications. The
reclaimed water provisions to on-site nonpotable water systems include gray water and other nonpotable water sources that are used for on-site applications. Water reuse is integral to sustainable water management because it allows water to remain in the environment and be preserved for future use while meeting the water requirements of the present. Water reuse reduces energy use by removing added potable water treatment, offsetting water demands, and providing water for energy production.
Chapter 16 Nonpotable Rainwater Catchment Systems.
Chapter 16 regulates nonpotable rainwater catchment systems that include irrigation; toilet and urinal flushing with proper treatment; provisions where permits are required; maintenance of alternate water sources; and minimum water quality. This chapter provides guidance on how to optimize rainwater use while ensuring there is a decrease of risk to consumers from poor design, installation, and maintenance. Rainwater harvesting is the process of capturing, channeling, and storing water runoff for later use. Most systems are constructed of three principal components: the catchment area, the collection device, and the conveyance system.
Chapter 17 Referenced Standards.
Chapter 17 provides two comprehensive tables with referenced standards. The standards listed in Table 1701.1 are applied as indicated in the applicable reference section(s). A list of additional approved standards, publications, practices, and guides that are not referenced in specific sections appear in Table 1701.2.
Referenced standards set forth specific details of accepted practices, materials specifications, or test methods in many specialized applications. Standards provide an efficient method of conveying complex information and specifications on the performance requirements for materials, products, systems, application, and installation. The manner and purpose for a standard’s use and, in turn, code compliance, must be definitive in all references to the standard. If the standard is intended to be a requirement for judging code compliance, the code must state its intent for use. The standard should adequately address a defined need and at the same time specify the minimum performance requirements, technical characteristics and methods of testing, and required test results.
The referenced standards tables are organized in a manner that makes it easy to find specific standards in alphabetical order, and by acronym of the publishing agency of the standard. The tables list the title of the standard, the edition, and any addenda. Contact information for each publishing agency is provided at the end of the chapter.
Appendix A Recommended Rules for Sizing the Water Supply System.
Appendix A provides a method of sizing the water supply and distribution system that provides precise calculations to establish the proper pressures and flow to the system’s fixtures. The goal of sizing the system is to deliver an acceptable volume of water to the most hydraulically remote fixture during minimum pressure and maximum flow conditions; provide satisfactory water pressure to the most hydraulically remote fixture during minimum pressure and maximum flow conditions; and to prevent excessive water velocity during maximum flow conditions.
Appendix B Explanatory Notes on Combination Waste and Vent Systems.
Appendix B contains general guidelines for the design and installation of combination waste and vent systems. These systems are designed for waste piping and are purposely oversized to serve as both a waste and vent pipe to avoid excessive pneumatic effects at fixture drains.
Appendix C Alternate Plumbing Systems.
The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate materials, and equipment that are not specifically covered in other parts of the code. Alternative methods are allowed to be used where approved by the authority having jurisdiction. Approval of alternatives is based on a demonstration showing that the method or material used is at least equivalent in strength, deflection, and capacity to that provided by the prescriptive methods and materials.
Appendix D Sizing Storm Water Drainage Systems.
Appendix D provides general guidelines for the sizing of stormwater drainage systems. There are two pieces of information that must always be a given. They are the roof size and the rate of rainfall for the area.
Appendix E Manufactured/Mobile Home Parks and Recreational Vehicle Parks.
The provisions of this appendix apply to the plumbing and drainage systems of mobile home and recreational vehicle parks. These provisions also apply to the use, maintenance, and installation for supplying fuel gas, water, electricity, and disposal of sewage from accessory buildings or structures, and building components.
Appendix F Firefighter Breathing Air Replenishment Systems.
Appendix F provides guidance on installing firefighter breathing air replenishment systems. System components include outside fire department connection panel, interior air fill panel or station, interconnected piping distribution system and pressure monitoring switch. Fire departments access the system through an outside connection panel and are able to pump air into the system. The firefighters inside the structure access the system at fill stations that are found throughout the building. The piping distribution system is made from stainless tubing or other approved materials. It delivers compressed air to the building’s interior air-fill stations and interior air-fill panels. The tubing also acts as a conduit in the interior of the building between the outside connection panel and the air storage system. If the system becomes over-pressurized, the air monitoring system also acts as a pressure relief. A system isolation valve is placed alongside each interior air fill station and interior air fill panel to isolate the system.
Appendix G Sizing of Venting Systems.
Appendix G provides added information on the sizing of gas vents. This appendix is useful to the end user for the proper sizing of venting systems. A series of examples are given that show how to use the tables and other requirements of Chapter 5.
Appendix H Private Sewage Disposal Systems.
Appendix H provides general guidelines for the materials, design, and installation of new or existing private sewage disposal systems. Where a building cannot be served by a public sewer system, the building site must be provided with a system for treating the wastewater generated from the use of plumbing fixtures in the building. The appendix addresses site evaluations, materials, soil absorption systems, holding tanks, cesspools, and on-site wastewater treatment systems. Private sewage disposal systems must be designed based on the soil conditions, constructed using approved materials, and installed according to prescribed dimensions.
Appendix I Installation Standards.
Installation standards are industry standards that specify procedures for the installation of plumbing and mechanical products, and the inspection methods and procedures employed for the examination of such systems. These comprehensive standards add detailed information and guidance that a manufacturer or product installation instructions may not fully address. These standards give the user confidence with options from industry experts for installing plumbing products and assemblies in a safe and professional manner.
Appendix J Combination of Indoor and Outdoor Combustion and Ventilation Opening Design.
Appendix J provides an example of how to determine the required combination of indoor and outdoor combustion air opening sizes for appliances. The combustion air example also provides a table that contains the required volume of a space per the appliance Btu/h input that is based on the standard method.
Appendix K Potable Rainwater Catchment Systems.
Potable rainwater catchment system is defined as a system that uses the principal of collecting and using rain from a rooftop or other man-made, aboveground collection surface. This appendix applies to new rainwater catchment installations, as well as changes, additions, maintenance, and repairs to existing installations. Rainwater harvesting is the practice of collecting the water produced during rainfall events before it has a chance to run off into a river or stream or soak into the ground and become groundwater.
Appendix L Sustainable Practices.
This appendix provides a comprehensive set of technically sound provisions that encourage sustainable practices and works toward improving the design and construction of plumbing systems that result in a positive long-term environmental impact. Environmental sustainability is important because it involves natural resources that human beings need for economic or manufactured capital. Their sustainability is defined by their reliance on infinitely available resources that are naturally occurring, constant, and free to access.
Appendix M Peak Water Demand Calculator.
This appendix provides a method for estimating the demand load for the building water supply and principal branches for single- and multi-family dwellings with water-conserving plumbing fixtures, fixture fittings, and appliances.
Appendix N Impact Of Water Temperature On The Potential For Scalding And Legionella Growth.
Legionnaires’ disease is a serious issue that is a threat to many citizens. It is known that the higher the temperature, the lower the risk for Legionella growth, but the higher the temperature, the higher the possibility for scalding. This appendix addresses Legionella growth potential and scald potential within specified temperature ranges. It contains definitions for terms used to describe water temperatures such as cold, tepid, warm, tempered hot, and disinfecting hot. Since plumbing systems operate within various temperature ranges, the public has a document that identifies such temperature ranges and the “potential” dangers within these temperature ranges.
Appendix O Non-Sewered Sanitation Systems.
This appendix contains provisions on non-sewered sanitation systems which are suitable for use in temporary or permanent settlements, including refugee camps, and are equally suited to both public and private use in isolated locations. Additionally, the appendix provides general safety and performance requirements for design and testing of non-sewered sanitation systems for prefabricated integrated treatment units. These systems will apply to any integrated sanitation system that is not attached to a sewer.
Appendix P Professional Qualifications.
Appendix P provides a baseline of knowledge for installers, inspectors, or employers working with and around the systems covered within the scope of this code to keep all persons safe and healthy.
Appendix Q Indoor Horticultural Facilities.
Appendix Q addresses plumbing systems for horticultural cultivation and processing of plants for human ingestion, inhalation, and topical application. The appendix provisions apply to primary and secondary horticultural facilities. Primary horticultural facilities are devoted to the growing and/or harvesting of plants. Cultivation rooms are located within these facilities, while a secondary horticultural facility is devoted to the harvesting (such as hulling or shelling), packing, and/or holding of plants.
Appendix R Tiny Houses.
Appendix R guidance for the tiny house communities including regulations for fixtures, approved materials, and provisions for protecting the potable water system. This appendix serves as a foundation to establish safe practices and requirements that will provide a safe, healthy, and reliable plumbing system for the tiny house.
Appendix S Onsite Stormwater Treatment Systems.
Appendix S provides provisions for the water quality, monitoring, design, construction, alteration, repair, and operation requirements of onsite stormwater treatment systems for nonpotable use.
SAMPLE LEGISLATION FOR ADOPTION OF THE UNIFORM PLUMBING CODE
The Uniform Codes are designed to be adopted by jurisdictions through an ordinance. Jurisdictions wishing to adopt the 2024 Uniform Plumbing Code as an enforceable regulation governing plumbing systems by reference should ensure the legal basis under which adoption and implementation are included in the ordinance.
The following sample ordinance is a guide for drafting an ordinance for adoption that addresses key components regulations and resolutions.
ORDINANCE NO.
An ordinance of the [JURISDICTION] adopting the 2024 edition of the Uniform Plumbing Code, regulating and controlling the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of plumbing systems in the [JURISDICTION]; providing for the issuance of permits and collection of fees therefor; repealing Ordinance No. of the [JURISDICTION] and all other ordinances and parts of the ordinances in conflict therewith.
The [GOVERNING BODY] of the [JURISDICTION] does ordain as follows:
Section 1 Codes Adopted by Reference. That certain documents, three (3) copies of which are on file in the office of the [JURISDICTION'S KEEPER OF RECORDS] and the [JURISDICTION], being marked and designated as the 2024 Uniform Plumbing Code, including Appendix Chapters [FILL IN THE APPENDIX CHAPTERS BEING ADOPTED], as published by the International Association of Plumbing and Mechanical Officials, be and is hereby adopted as the Code of the [JURISDICTION], in the State of [STATE NAME] regulating and controlling the design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of plumbing systems as herein provided; providing for the issuance of permits and collection of fees therefor; and each and all of the regulations, provisions, penalties, conditions and terms of such 2024 Uniform Plumbing Code on file in the office of the
[JURISDICTION] are hereby referred to, adopted, and made a part hereof, as if fully set out in this ordinance.
Section 2 Modifications. The following sections are hereby revised: Section 101.1. Insert: [NAME OF JURISDICTION] Section 104.5. Insert: [APPROPRIATE FEE SCHEDULE]
Section 3 Conflicting Ordinances Repealed. That Ordinance No. of [JURISDICTION] entitled
[TITLE OF THE ORDINANCE OR ORDINANCES IN EFFECT AT THE PRESENT TIME SO THAT THEY WILL BE REPEALED BY MENTION] and all other ordinances or parts of ordinances in conflict herewith are hereby repealed.
Section 4 Preemption. [JURISDICTION] hereby fully occupies and preempts the entire field of regulation of design, construction, quality of materials, erection, installation, alteration, repair, location, relocation, replacement, addition to, use or maintenance of plumbing systems; and provision for the issuance of permits and collection of fees therefor; within the boundaries of [JURISDICTION]. [AS APPROPRIATE] Cities, towns, and counties or other municipalities may enact only those laws and ordinances relating to this field as specifically authorized by state law and consistent with this ordinance. Local laws and ordinances that are inconsistent with, more restrictive than, or exceed the requirements of [ORDINANCE NO.] shall not be enacted and are hereby expressly preempted and repealed, regardless of the nature of the code, charter, or home rule status of such city, town, county, or municipality.
Section 5 Severability. That if any section, subsection, sentence, clause or phrase of this ordinance is, for any reason, held to be unconstitutional, such decision shall not affect the validity of the remaining portions of this ordinance. The [GOVERNING BODY] hereby declares that it would have passed this ordinance, and each section, subsection, clause or phrase thereof, irrespective of the fact that any one or more sections, subsections, sentences, clauses and phrases be declared unconstitutional.
Section 6 Legal Notice. That the [JURISDICTION'S KEEPER OF RECORDS] is hereby ordered and directed to cause this ordinance to be published. (An additional provision may be required to direct the number of times the ordinance is to be published and to specify that it is to be in a newspaper in general circulation. Posting may also be required.)
Section 7 Violations and Penalties. [INCORPORATE PENALTIES FOR VIOLATIONS]
Section 8 Effective Date. That this ordinance and the rules, regulations, provisions, requirements, orders and matters established and adopted hereby shall take effect and be in full force and effect [TIME PERIOD] from and after the date of its final passage and adoption.
COMMITTEE ON UNIFORM PLUMBING CODE
These lists represent the membership at the time the Committee was balloted on the final text of this edition. Since that time, changes in the membership may have occurred.
IAPMO Standards Council Bill Erickson, Chairperson CJ Erickson Plumbing Company [I/M]
JT Baca, State of New Mexico [E] Laura Ceja, United Association [L] Rick Coffman, City of Cedar Falls, Retired [C] Marty Cooper, Vice Chairperson, City of Foster City [E]
Jim Imprescia, City of Leominster [E] Doug Marian, District Council 16 [L] Jim Stack, Stack Plumbing, Inc. [I/M] Don Summers, Plumber’s & Pipefitters Training Center [L]
Nonvoting
Gabriella M. Davis, Secretary, IAPMO Hugo Aguilar, Recording Secretary, IAPMO
IAPMO Uniform Plumbing Code Technical Committee Dan Daniels, Chairperson, Self [C]
Bob Adler, 4Leaf, Inc. [E] Sarah Aguilar, McCabe Plumbing [I/M] Rawand Aryan, City of Los Angeles Department of Building & Safety [E] Julius Ballanco, JB Engineering & Code Consulting [SE] DJ Berger, National ITC Corporation [U] Gary Bonetti, UA Local #342 JATC [L] Jeremy Brown, NSF International [R/S/T] Michael Cudahy, Plastic Pipe & Fittings Association (PPFA) [M] Pennie Feehan, Copper Development Association (CDA) [M] Brian Fenty, Self [E] Ed Gormley, Gormley Plumbing & Mechanical [I/M] Lingyan Gorsuch, Arup [SE]
Ephraim Kreitenberg, Kreit Mechanical Associates, Inc. [SE] David Mann, CA State Pipe Trades Council [L] John Nielsen, State of Idaho – Division of Building Safety [E] Johnnie Norris, United Association [L] Phil Ribbs, PHR Consultants [SE] Arnold Rodio, Pace Setter Plumbing [I/M] Brad Senecaut, City of Hillsboro [E] Robert Sewell, Lescure Company [U] Larry Soskin, ACE Duraflo [M] Billy Smith, American Society of Plumbing Engineers (ASPE) [SE] Don Taylor, Dittmann Plumbing [U] Chuck White, Plumbing-Heating-Cooling Contractors National Association (PHCC-NA) [I/M]
Alternates
Chris Cheek, National ITC Corporation [U] Richard Church, Plastic Pipe & Fittings Association (PPFA) [M] Tim Knight, UA Local #342 JATC [L] Ramiro Mata, American Society of Plumbing Engineers (ASPE) [SE]
David Orton, NSF International [R/S/T] Dan Rademacher, United Association [L] Martin Salberg, Pace Setter Plumbing [I/M] Kevin Sullivan, UA Local #342 JATC [L]
Nonvoting
Matthew Barker, National Fire Protection Association (NFPA) [R/S/T] David Gans, Ex-Officio, IAPMO [E] Enrique Gonzalez, IAPMO Staff Liaison
Alexander Ing, National Fire Protection Association (NFPA) [R/S/T] Doug Marian, ASSE [R/S/T]
COMMITTEE MEMBERSHIP CLASSIFICATION ABBREVIATIONS
These classifications apply to Technical Committee members and represent their principal interest in the activity of a committee.
M Manufacturer: A representative of a maker or marketer of a product, assembly or system, or portion thereof, that is affected by the standard. U User: A representative of an entity that is subject to the provisions of the standard or that voluntarily uses the standard. I/M Installer/Maintainer: A representative of an entity that is in the business of installing or maintaining a product, assembly or system affected by the standard. L Labor: A labor representative or employee concerned with safety in the workplace. R/S/T Research/Standards/Testing Laboratory: A representative of an independent research organization; an organization that develops codes, standards or other similar documents; or an independent testing laboratory. E Enforcing Authority: A representative or an agency or an organization that promulgates and/or enforces standards. C Consumer: A person who is, or represents, the ultimate purchaser of a product, system, or service affected by the standard, but who is not included in the User classification. SE Special Expert: A person not representing any of the previous classifications, but who has special expertise in the scope of the standard or portion thereof.
SECTION RELOCATION
| 2024 Location | 2021 Location |
|---|---|
| L 411.14 - L 411.14.3 | L 411.10 - L 411.10.3 |
| L 411.16 - L 411.17 | L 411.12 - L 411.13 |
| Table L 502.7.1 | Table L 502.7 |
| L 503.2.1 | L 503.2 |
| N 102.1 | N 102.1 - N 102.10 |
| 206.0 Diverter Valve, Gray Water |
209.0 Gray Water Diverter Valve |
| 212.0 Joint, Heat-Fusion | 210.0 Heat-Fusion Weld Joints |
| 408.3 - 408.4.2 | 408.2 - 408.3.2 |
| 408.5 - 408.11 | 408.4 - 408.10 |
| 409.6.2 | 409.6.1 |
| 422.1.2 | 422.1.1 |
| 507.21 - 507.26 | 507.22 - 507.27 |
| 509.8.1 | 509.8.2 |
| Figure 509.8.1 | Figure 509.8 |
| Table 509.8.1 | Table 509.8.2 |
| 509.8.2, 509.8.3 | 509.8.4, 509.8.5 |
| 509.10.7 - 509.10.13.1 | 509.10.6 - 509.10.12.1 |
| 603.5.20 - 603.5.22 | 603.5.19 - 603.5.21 |
| 607.3 - 607.6 | 607.2 - 607.5 |
| 1017.4 | 1017.2 |
| 1208.2 - 1208.5.1 | 1208.3 - 1208.6.1 |
| Table 1208.3.1 | Table 1208.4.1 |
| 1208.5.2 - 1208.5.8.2 | 1208.6.3 - 1208.6.9.2 |
| Table 1208.5.8.2 | Table 1208.6.9.2 |
| 1208.5.8.3 - 1208.7.3 | 1208.6.9.3 - 1208.8.3 |
| 1208.7.4 | 1208.8.4 |
| 1208.7.5 - 1208.14.1 | 1208.8.7 - 1208.15.1 |
| 1212.1.2, 1212.1.3 | 1212.1.1, 1212.1.2 |
| 1323.13.3, 1323.13.4 | 1323.13.2, 1323.13.3 |
| 1326.4 - 1326.10 | 1326.5 - 1326.11 |
| 1505.6 - 1505.14 | 1505.5 - 1505.13 |
| Figure 1505.10 | Figure 1505.9 |
| 1506.6 - 1506.13 | 1506.5 - 1506.12 |
| 1603.3 - 1603.4 | 1603.4 - 1603.5 |
| Table 1603.4 | Table 1603.5 |
| 1603.5 - 1603.19 | 1603.6 - 1603.20 |
| 1603.20 | 1503.2.4 |
| L 402.9 - L 402.11 | L 402.8 - L 402.10 |
| L 404.9 - L 404.12 | L 404.8 - L 404.11 |
| L 411.5, L 411.6 | L 411.2, L411.3 |
| L 411.7 | L 411.4 |
| L 411.9 - L 411.12 | L 411.5 - L 411.8 |
The Documents Listed are Not by this Reference Adopted by The State of California.
IAPMO provides a variety of other products which are useful for inspectors, building officials, architects, engineers,
manufacturers, contractors, plumbers, and apprentices.
IAPMO Headquarters Directory
4755 East Philadelphia Street, Ontario, California 91761-2816
Publication Order Desk Phone: 800-85-IAPMO
Publication Toll Free Fax: 877-85-CODES
E-mail: iapmo@iapmo.org
Website: www.iapmo.org
Free Code Question: 800-201-0335
Uniform Plumbing Code – 2024 Edition:
The Uniform Plumbing Code is the most widely adopted plumbing code in the world. The 2024 edition contains complete “turnkey” requirements for the installation and maintenance of plumbing systems, all in one easy to use book.
Uniform Plumbing Code Illustrated Training Manual:
The UPC Illustrated Training Manual is an excellent reference for anyone involved in the plumbing industry. It contains an extensive definitions section and several hundred comprehensive technical diagrams and illustrations. It serves as a textbook, and it also is useful as a valuable tool for explaining the intent and use of the Code.
Uniform Plumbing Code Study Guide:
This book is the perfect complement to the UPC Illustrated Training Manual. Alone, it constitutes a complete self-study course for learning the UPC. It has hundreds of questions, general practice exams, and plumbing math, pipe sizing exercises and fitting identification. A big help in getting you ready for a certification exam!
Guide to Important Code Questions to the Uniform Plumbing Code:
An excellent reference for learning and understanding plumbing code changes and identifies code changes between editions. It is a useful tool for preparing code change proposals.
Uniform Mechanical Code – 2024 Edition:
The Uniform Mechanical Code contains complete requirements for the installation and maintenance of heating, ventilating, cooking and refrigeration systems.
Uniform Mechanical Code Illustrated Training Manual:
Contains technical diagrams and illustrations that demonstrate the intent and use of the UMC. A great reference for everyone involved in Mechanical HVACR design and installation.
Uniform Mechanical Code Study Guide:
The Study Guide is a complete self-study course for learning the UMC. A big help in getting ready for a certification exam! This book is the perfect complement to the UMC Illustrated Training Manual.
Guide to Important Code Questions to the Uniform Mechanical Code:
An excellent reference for learning and understanding mechanical code changes and identifies code changes between editions. It is a useful tool for preparing code change proposals.
The Documents Listed are Not by this Reference Adopted by The State of California.
Uniform Swimming Pool, Spa, and Hot Tub Code – 2024 Edition: The Uniform Swimming Pool, Spa and Hot Tub Code contains complete and current requirements for the erection, installation, alteration, repair, relocation, replacement, addition to and use or maintenance of these systems.
Uniform Solar, Hydronics and Geothermal Code – 2024 Edition: The Uniform Solar, Hydronics and Geothermal Code contains complete requirements for the erection, installation, alteration, addition, repair, relocation, replacement, addition to, use or maintenance of these systems.
Drain Waste and Vent Calculator:
A slide-rule style calculator provides quick and simple access to the fixture unit and sizing tables of Chapter 7 of the UPC.
Water Sizing Calculator: Sizing water systems becomes a much simpler task with the use of this handy slide-rule style calculator.
Natural Gas Pipe Sizing Calculator: This Natural Gas Pipe Sizing Calculator is presented in an easy to use and read slide-rule format. Designed for systems with a supply pressure of six to eight inches of water column, all pipe capacities are given in cubic feet per hour.
Trailer Standards:
IAPMO has developed a number of standards for specialty products used in manufactured homes and recreational vehicles. These standards are available individually, or they may be purchased as a set.
Education and Training Seminars: IAPMO specializes in conducting training and education, including fulfilling continuing education requirements, on the UPC and UMC as well as all of the most commonly utilized codes in the Construction Trades. Special seminars on industry or code subjects are expeditiously created and delivered upon request. Please call to obtain the seminar schedule or to arrange for a custom special seminar.
Backflow Prevention Institute – IAPMO:
The IAPMO Backflow Prevention Institute provides professional education and training for the control of hazards to our water supply and is dedicated to water-system safety worldwide. The Institute provides training in backflow prevention and cross-connection control. This program includes backflow preventers, testers, repairers, cross-connection control surveyors, program administrators and fire-sprinkler backflow preventer testers. Each of these courses provides compliance certification to American Society of Sanitary Engineering (ASSE) Series 5000 Professional Qualification Standards.
Backflow Prevention Reference Manual:
This unique 300-page manual contains full-color illustrations and sections relating to real-world installations, backflow prevention, testing cross-connection control, repair and inspections. The manual is an excellent textbook and a reference the inspectors in every jurisdiction should have access too. It is also an important resource for system designers, urban planners and utility companies – professionals on both sides of the water meter.
ANSI Z 124 Standards:
These standards are written to specifically address a variety of plastic plumbing fixtures and components. They are available individually, or may be grouped for quantity discounts.
IAPMO Installation Standards:
IAPMO standards committees have formulated installation standards for a wide variety of commonly used plumbing materials and systems. The IAPMO installation standards are included after the text of the Uniform Plumbing Code, or can be purchased separately.
The Documents Listed are Not by this Reference Adopted by The State of California.
Material and Property Standards: IAPMO does not generally develop material and property standards, but when a need exists the Association will take a leadership role by filling the void. They are available, are subject to amendments and are withdrawn when recognized consensus standards are formulated.
OFFICIAL Magazine: IAPMO’s quarterly publication features informative articles related to Plumbing and Mechanical HVACR installations, award winning general interest features, technical columns and industry updates. Subscriptions are available and all IAPMO members receive a free copy of every issue!
Membership in IAPMO: IAPMO membership is open to all interested persons. Membership categories include Student, Individual, Senior, Organizational and Governmental. Member benefits include discounted prices on IAPMO publications, a subscription to Official magazine, and numerous educational and training opportunities.
HOW TO CONTACT IAPMO
Mailing Address: 4755 East Philadelphia Street, Ontario, California 91761-2816
Main Number: 909-472-4100 • Publication Orders: 800-85-IAPMO • Publication Fax: 877-85-CODES
Website: www.iapmo.org • Office Hours: Monday – Friday, 8am – 5pm Pacific Time
Table of Contents¶
TABLE OF CONTENTS
CHAPTER 1 DIVISION I
CALIFORNIA ADMINISTRATION . . . .1
1.1.0 General . . . . . . . . . . . . . . . . . . . . . . .3
1.1.1 Title . . . . . . . . . . . . . . . . . . . . . . . . . .3
1.1.2 Purpose . . . . . . . . . . . . . . . . . . . . . .3
1.1.3 Scope . . . . . . . . . . . . . . . . . . . . . . . .3
1.1.4 Appendices . . . . . . . . . . . . . . . . . . .4
1.1.5 Referenced Codes . . . . . . . . . . . . . .4
1.1.6 Non-Building Standards, Orders, and Regulations . . . . . . . . . . . . . . . .4
1.1.7 Order of Precedence and Use . . . .4
1.1.8 City, County, or City and County Amendments, Additions or Deletions . . . . . . . . . . .4
1.1.9 Effective Date of this Code . . . . . . .5
1.1.10 Availability of Codes . . . . . . . . . . . . .5
1.1.11 Format . . . . . . . . . . . . . . . . . . . . . . .5
1.1.12 Validity . . . . . . . . . . . . . . . . . . . . . . .5
1.2.0 Building Standards Commission . . .5
1.2.1 BSC . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2.2 BSC-CG . . . . . . . . . . . . . . . . . . . . . .6
1.2.3 Alternate Materials, Design, and Methods of Construction
and Equipment . . . . . . . . . . . . . . . . .6
1.3.0 Board of State and Community Corrections . . . . . . . . . . . . . . . . . . . .6
1.3.2 Adopting Agency Identification . . . .7
1.4.0 Department of Consumer Affairs . . .7
1.4.2 Adopting Agency Identification . . . .7
1.5.0 Reserved for California
Energy Commission . . . . . . . . . . . . .7
1.6.0 Department of Food and Agriculture . . . . . . . . . . . . . . . . .7
1.6.2 Adopting Agency Identification . . . .7
1.7.0 Department of Public Health . . . . . .7
1.7.2 Adopting Agency Identification . . . .7
1.8.0 Department of Housing and Community Development . . . . . . . . .7
1.8.1 Purpose . . . . . . . . . . . . . . . . . . . . . .7
1.8.2 Authority and Abbreviations . . . . . . .7
1.8.3 Local Enforcing Agency . . . . . . . . . .8
1.8.4 Permits, Fees, Applications, and Inspections . . . . . . . . . . . . . . . .9
1.8.5 Right of Entry for Enforcement . . . .10
1.8.6 Local Modification by Ordinance or Regulation . . . . . . . .10
1.8.7 Alternate Materials, Designs, Tests, and Methods of Construction . . . . .10
1.8.8 Appeals Board . . . . . . . . . . . . . . . .11
1.8.9 Unsafe Buildings or Structures . . .12
1.8.10 Other Building Regulations . . . . . .12
1.9.0 Division of the State Architect . . . .13
1.9.1 Division of the State Architect – Access Compliance . . . . . . . . . . . .13
1.9.2 Division of the State Architect – Structural Safety . . . . . . . . . . . . . . .13
1.10.0 Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development . . . . . . . . . . . . . .13
1.10.1 OSHPD 1 and OSHPD 1R . . . . . . .13
1.10.2 OSHPD 2 . . . . . . . . . . . . . . . . . . . .13
1.10.3 OSHPD 3 . . . . . . . . . . . . . . . . . . . .14
1.10.4 OSHPD 4 . . . . . . . . . . . . . . . . . . . .14
1.10.5 OSHPD 5 . . . . . . . . . . . . . . . . . . . .14
1.10.6 OSHPD 6 . . . . . . . . . . . . . . . . . . . .15
1.11.0 Office of the State Fire Marshal . . .15
1.11.1 SFM-Office of the
State Fire Marshal . . . . . . . . . . . . .15
1.11.2 Duties and Powers of
the Enforcing Agency . . . . . . . . . . .16
1.11.3 Construction Documents . . . . . . . .18
1.11.4 Fees . . . . . . . . . . . . . . . . . . . . . . . .18
1.11.5 Inspections . . . . . . . . . . . . . . . . . . .19
1.11.6 Certificate of Occupancy . . . . . . . .19
1.11.7 Temporary Structures and Uses . .19
1.11.8 Service Utilities . . . . . . . . . . . . . . . .19
1.11.9 Stop Work Order . . . . . . . . . . . . . .19
1.11.10 Unsafe Buildings, Structures, and Equipment . . . . . . . . . . . . . . . .19
1.11.11 Adopting Agency Identification . . .19
1.12.0 Reserved for the State Librarian . .19
1.13.0 Department of Water Resources (DWR) . . . . . . . . . . . . .19
1.13.1 Application . . . . . . . . . . . . . . . . . . .19
1.13.2 Adopting Agency Identification . . .19
1.14.0 Reserved for the State
Lands Commission . . . . . . . . . . . . .19
CHAPTER 1 DIVISION II
SCOPE AND ADMINISTRATION . .21
101.0 General . . . . . . . . . . . . . . . . . . . . . .21
101.1 Title . . . . . . . . . . . . . . . . . . . . . . . . .21
TABLE OF CONTENTS
101.2 Scope . . . . . . . . . . . . . . . . . . . . . . .21
101.3 Purpose . . . . . . . . . . . . . . . . . . . . .21
101.4 Unconstitutional . . . . . . . . . . . . . . .21
101.5 Validity . . . . . . . . . . . . . . . . . . . . . .21
102.0 Applicability . . . . . . . . . . . . . . . . . . .21
102.1 Conflicts Between Codes . . . . . . . .21
102.2 Existing Installations . . . . . . . . . . . .21
102.3 Maintenance . . . . . . . . . . . . . . . . . .21
102.4 Additions, Alterations, Renovations, or Repairs . . . . . . . . .21
102.5 Health and Safety . . . . . . . . . . . . . .21
102.6 Changes in Building Occupancy . . .21
102.7 Moved Structures . . . . . . . . . . . . . .21
102.8 Appendices . . . . . . . . . . . . . . . . . . .21
103.0 Duties and Powers of the
Authority Having Jurisdiction . . . . .22
103.1 General . . . . . . . . . . . . . . . . . . . . . .22
103.2 Liability . . . . . . . . . . . . . . . . . . . . . .22
103.3 Applications and Permits . . . . . . . .22
103.4 Right of Entry . . . . . . . . . . . . . . . . .22
104.0 Permits . . . . . . . . . . . . . . . . . . . . . .22
104.1 Permits Required . . . . . . . . . . . . . .22
104.2 Exempt Work . . . . . . . . . . . . . . . . .22
104.3 Application for Permit . . . . . . . . . . .22
104.4 Permit Issuance . . . . . . . . . . . . . . .23
104.5 Fees . . . . . . . . . . . . . . . . . . . . . . . .24
105.0 Inspections and Testing . . . . . . . . .24
105.1 General . . . . . . . . . . . . . . . . . . . . . .24
105.2 Required Inspections . . . . . . . . . . .24
105.3 Testing of Systems . . . . . . . . . . . . .25
105.4 Connection to Service Utilities . . . .25
106.0 Violations and Penalties . . . . . . . . .25
106.1 General . . . . . . . . . . . . . . . . . . . . . .25
106.2 Notices of Correction or Violation . . .25
106.3 Penalties . . . . . . . . . . . . . . . . . . . . .26
106.4 Stop Orders . . . . . . . . . . . . . . . . . .26
106.5 Authority to Disconnect Utilities in Emergencies . . . . . . . . .26
106.6 Authority to Condemn . . . . . . . . . . .26
107.0 Board of Appeals . . . . . . . . . . . . . .26
107.1 General . . . . . . . . . . . . . . . . . . . . . .26
107.2 Limitations of Authority . . . . . . . . . .26
Table 104.5 Plumbing Permit Fees . . . . . . . . . .27
CHAPTER 2 DEFINITIONS . . . . . . . . . . . . . . . . .29
201.0 General . . . . . . . . . . . . . . . . . . . . . .31
201.1 Applicability . . . . . . . . . . . . . . . . . . .31
202.0 Definition of Terms . . . . . . . . . . . . .31
202.1 General . . . . . . . . . . . . . . . . . . . . . .31
CHAPTER 3 GENERAL REGULATIONS . . . . . .47
301.0 General . . . . . . . . . . . . . . . . . . . . . .49
301.1 Applicability . . . . . . . . . . . . . . . . . . .49
301.2 Minimum Standards . . . . . . . . . . . .49
301.3 Alternate Materials and Methods
of Construction Equivalency . . . . . .49
301.4 Flood Hazard Areas . . . . . . . . . . . .49
301.5 Alternative Engineered Design . . . .50
301.6 Tall Wood (Mass Timber) Buildings . . . . . . . . . . . . . . . . . . . . .50
301.7 One- and Two-Family Dwellings . .50
301.8 OSHPD 1R . . . . . . . . . . . . . . . . . . .50
302.0 Iron Pipe Size (IPS) Pipe . . . . . . . .50
302.1 General . . . . . . . . . . . . . . . . . . . . . .50
303.0 Disposal of Liquid Waste . . . . . . . .50
303.1 General . . . . . . . . . . . . . . . . . . . . . .50
304.0 Connections to Plumbing System Required . . . . . . . . . . . . . .50
304.1 General . . . . . . . . . . . . . . . . . . . . . .50
305.0 Damage to Drainage System or Public Sewer . . . . . . . . . . . . . . .51
305.1 Unlawful Practices . . . . . . . . . . . . .51
306.0 Industrial Wastes . . . . . . . . . . . . . .51
306.1 Detrimental Wastes . . . . . . . . . . . .51
306.2 Safe Discharge . . . . . . . . . . . . . . . .51
307.0 Location . . . . . . . . . . . . . . . . . . . . .51
307.1 System . . . . . . . . . . . . . . . . . . . . . .51
307.2 Ownership . . . . . . . . . . . . . . . . . . .51
308.0 Prohibited Locations . . . . . . . . . . . .51
308.1 General . . . . . . . . . . . . . . . . . . . . . .51
309.0 Workmanship . . . . . . . . . . . . . . . . .51
309.1 Engineering Practices . . . . . . . . . . .51
309.2 Concealing Imperfections . . . . . . . .51
309.3 Burred Ends . . . . . . . . . . . . . . . . . .51
309.4 Installation Practices . . . . . . . . . . . .51
309.5 Sound Transmission . . . . . . . . . . . .51
309.6 Dead Legs . . . . . . . . . . . . . . . . . . .51
310.0 Prohibited Fittings and Practices . . . . . . . . . . . . . . . . . . . . .51
310.1 Fittings . . . . . . . . . . . . . . . . . . . . . .51
310.2 Drainage and Vent Piping . . . . . . .51
310.3 Waste Connection . . . . . . . . . . . . .51
310.4 Use of Vent and Waste Pipes . . . .51
310.5 Obstruction of Flow . . . . . . . . . . . .51
310.6 Dissimilar Metals . . . . . . . . . . . . . .51
310.7 Direction of Flow . . . . . . . . . . . . . . .51
310.8 Screwed Fittings . . . . . . . . . . . . . . .51
310.9 Female Plastic Connections . . . . . .52
TABLE OF CONTENTS
310.10 ABS and PVC Transition Joints . . .52
310.14 Services/Systems and Utilities . . . .52
310.15 Telephone and Data Equipment Rooms . . . . . . . . . . . . .52
311.0 Independent Systems . . . . . . . . . . .52
311.1 General . . . . . . . . . . . . . . . . . . . . . .52
312.0 Protection of Piping, Tubing, Materials, and Structures . . . . . . . .52
312.1 General . . . . . . . . . . . . . . . . . . . . . .52
312.2 Installation . . . . . . . . . . . . . . . . . . .52
312.3 Building Sewer and Drainage Piping . . . . . . . . . . . . . . . . . . . . . . .52
312.4 Corrosion, Erosion, and Mechanical Damage . . . . . . . . . . . .52
312.5 Protectively Coated Pipe . . . . . . . .52
312.6 Freezing Protection . . . . . . . . . . . .52
312.7 Fire-Resistant Construction . . . . . .52
312.8 Waterproofing of Openings . . . . . .52
312.9 Steel Nail Plates . . . . . . . . . . . . . . .52
312.10 Sleeves . . . . . . . . . . . . . . . . . . . . . .52
312.11 Structural Members . . . . . . . . . . . .53
312.12 Rodentproofing . . . . . . . . . . . . . . . .53
313.0 Hangers, Supports, and Anchors . . .53
313.1 General . . . . . . . . . . . . . . . . . . . . . .53
313.2 Material . . . . . . . . . . . . . . . . . . . . . .53
313.3 Suspended Piping . . . . . . . . . . . . .53
313.4 Alignment . . . . . . . . . . . . . . . . . . . .53
313.5 Underground Installation . . . . . . . .53
313.6 Hanger Rod Sizes . . . . . . . . . . . . .53
Table 313.6 Hanger Rod Sizes . . . . . . . . . . . . .53
313.7 Gas Piping . . . . . . . . . . . . . . . . . . .53
314.0 Trenching, Excavation, and Backfill . . . . . . . . . . . . . . . . . . . . . .53
314.1 Trenches . . . . . . . . . . . . . . . . . . . . .53
314.2 Tunneling and Driving . . . . . . . . . .53
314.3 Open Trenches . . . . . . . . . . . . . . . .53
314.4 Excavations . . . . . . . . . . . . . . . . . .53
315.0 Joints and Connections . . . . . . . . .54
315.1 Unions . . . . . . . . . . . . . . . . . . . . . .54
315.2 Prohibited Joints and
Connections . . . . . . . . . . . . . . . . . .54
316.0 Increasers and Reducers . . . . . . . .54
316.1 General . . . . . . . . . . . . . . . . . . . . . .54
317.0 Food-Handling Establishments . . . .54
317.1 General . . . . . . . . . . . . . . . . . . . . . .54
318.0 Test Gauges . . . . . . . . . . . . . . . . . .54
318.1 General . . . . . . . . . . . . . . . . . . . . . .54
318.2 Pressure Tests (10 psi or less) . . .54
318.3 Pressure Tests (greater than 10 psi to 100 psi) . . . . . . . . . . . . . .54
318.4 Pressure Tests (exceeding 100 psi) . . . . . . . . . . . . . . . . . . . . . .54
318.5 Pressure Range . . . . . . . . . . . . . . .54
319.0 Medical Gas and Vacuum
Systems . . . . . . . . . . . . . . . . . . . . .54
319.1 General . . . . . . . . . . . . . . . . . . . . . .54
320.0 Rehabilitation of Piping Systems . .54
320.1 General . . . . . . . . . . . . . . . . . . . . . .54
321.0 Essential Plumbing Provisions . . . .54
322.0 Psychiatric Services . . . . . . . . . . . .54
323.0 Plumbing Equipment Schedules . . .55
Table 313.3 Hangers and Supports . . . . . . . . . .55
CHAPTER 4 PLUMBING FIXTURES
AND FIXTURE FITTINGS . . . . . . .57
401.0 General . . . . . . . . . . . . . . . . . . . . . .59
401.1 Applicability . . . . . . . . . . . . . . . . . . .59
401.2 Quality of Fixtures . . . . . . . . . . . . .59
401.3 Water-Conserving Fixtures and Fittings . . . . . . . . . . . . . . . . . . .59
402.0 Installation . . . . . . . . . . . . . . . . . . .59
402.1 Cleaning . . . . . . . . . . . . . . . . . . . . .59
402.2 Joints . . . . . . . . . . . . . . . . . . . . . . .59
402.3 Securing Fixtures . . . . . . . . . . . . . .59
402.4 Wall-Hung Fixtures . . . . . . . . . . . . .59
402.5 Setting . . . . . . . . . . . . . . . . . . . . . .59
402.6 Flanged Fixture Connections . . . . .59
402.7 Supply Fittings . . . . . . . . . . . . . . . .60
402.8 Installation . . . . . . . . . . . . . . . . . . .60
402.9 Design and Installation of Plumbing Fixtures . . . . . . . . . . . . . .60
402.10 Slip Joint Connections . . . . . . . . . .60
402.11 Future Fixtures . . . . . . . . . . . . . . . .60
403.0 Accessible Plumbing Facilities . . . .60
403.1 General . . . . . . . . . . . . . . . . . . . . . .60
403.2 Fixtures and Fixture Fittings for Persons with Disabilities . . . . . .60
403.3 Exposed Pipes and Surfaces . . . . .60
404.0 Waste Fittings and Overflows . . . . .60
404.1 Waste Fittings . . . . . . . . . . . . . . . . .60
404.2 Overflows . . . . . . . . . . . . . . . . . . . .60
405.0 Prohibited Fixtures . . . . . . . . . . . . .60
405.1 Prohibited Water Closets . . . . . . . .60
405.2 Prohibited Urinals . . . . . . . . . . . . . .60
405.3 Miscellaneous Fixtures . . . . . . . . . .60
406.0 Special Fixtures and Specialties . . .61
406.1 Water and Waste Connections . . . .61
406.2 Special Use Sinks . . . . . . . . . . . . .61
406.3 Special Use Fixtures . . . . . . . . . . .61
TABLE OF CONTENTS
406.4 Zinc Alloy Components . . . . . . . . .61
407.0 Lavatories . . . . . . . . . . . . . . . . . . . .61
407.1 Application . . . . . . . . . . . . . . . . . . .61
407.2 Water Consumption . . . . . . . . . . . .61
407.3 Limitation of Hot Water
Temperature for Public Lavatories . . . . . . . . . . . . . . . . . . . .61
407.4 Transient Public Lavatories . . . . . .61
407.5 Waste Outlet . . . . . . . . . . . . . . . . . .61
407.6 Overflow . . . . . . . . . . . . . . . . . . . . .61
408.0 Showers . . . . . . . . . . . . . . . . . . . . .61
408.1 Application . . . . . . . . . . . . . . . . . . .61
408.2 Tileable Shower Receptors . . . . . .61
408.3 Water Consumption . . . . . . . . . . . .61
408.4 Individual Shower and
Tub-Shower Combination
Control Valves . . . . . . . . . . . . . . . .62
408.5 Waste Outlet . . . . . . . . . . . . . . . . . .62
408.6 Finished Curb or Threshold . . . . . .62
408.7 Shower Compartments . . . . . . . . . .62
408.8 Lining for Showers and Receptors . . . . . . . . . . . . . . . . . . . .62
408.9 Public Shower Floors . . . . . . . . . . .63
408.10 Location of Valves and Heads . . . . .63
408.11 Water Supply Riser . . . . . . . . . . . .63
409.0 Bathtubs and Whirlpool Bathtubs . . . . . . . . . . . . . . . . . . . . .63
409.1 Application . . . . . . . . . . . . . . . . . . .63
409.2 Waste Outlet . . . . . . . . . . . . . . . . . .63
409.3 Overflow . . . . . . . . . . . . . . . . . . . . .63
409.4 Limitation of Hot Water
Temperature in Bathtubs and Whirlpool Bathtubs . . . . . . . . .63
409.5 Backflow Protection . . . . . . . . . . . .64
409.6 Installation and Access . . . . . . . . . .64
410.0 Bidets . . . . . . . . . . . . . . . . . . . . . . .64
410.1 Application . . . . . . . . . . . . . . . . . . .64
410.2 Backflow Protection . . . . . . . . . . . .64
410.3 Limitation of Water
Temperature in Bidets . . . . . . . . . .64
411.0 Water Closets . . . . . . . . . . . . . . . . .64
411.1 Application . . . . . . . . . . . . . . . . . . .64
411.2 Water Consumption . . . . . . . . . . . .64
411.3 Water Closet Seats . . . . . . . . . . . .64
411.4 Personal Hygiene Devices . . . . . . .64
412.0 Urinals . . . . . . . . . . . . . . . . . . . . . .64
412.1 Application . . . . . . . . . . . . . . . . . . .64
412.2 Backflow Protection . . . . . . . . . . . .65
413.0 Flushing Devices . . . . . . . . . . . . . .65
413.1 Where Required . . . . . . . . . . . . . . .65
413.2 Flushometer Valves . . . . . . . . . . . .65
413.3 Flush Tanks . . . . . . . . . . . . . . . . . .65
413.4 Water Supply for Flush Tanks . . . .65
413.5 Overflows in Flush Tanks . . . . . . . .65
414.0 Dishwashing Machines . . . . . . . . . .65
414.1 Application . . . . . . . . . . . . . . . . . . .65
414.2 Backflow Protection . . . . . . . . . . . .65
414.3 Drainage Connection . . . . . . . . . . .65
414.4 Lead Content . . . . . . . . . . . . . . . . .65
415.0 Drinking Fountains . . . . . . . . . . . . .65
415.1 Application . . . . . . . . . . . . . . . . . . .65
415.2 Drinking Fountain Alternatives . . . .66
415.3 Drainage Connection . . . . . . . . . . .66
415.4 Location . . . . . . . . . . . . . . . . . . . . .66
416.0 Emergency Eyewash and Shower Equipment . . . . . . . . . . . . .66
416.1 Application . . . . . . . . . . . . . . . . . . .66
416.2 Water Supply . . . . . . . . . . . . . . . . .66
416.3 Installation . . . . . . . . . . . . . . . . . . .66
416.4 Location . . . . . . . . . . . . . . . . . . . . .66
416.5 Drain . . . . . . . . . . . . . . . . . . . . . . . .66
417.0 Faucets and Fixture Fittings . . . . . .66
417.1 Application . . . . . . . . . . . . . . . . . . .66
417.2 Deck Mounted Bath/Shower
Valves . . . . . . . . . . . . . . . . . . . . . . .66
417.3 Handheld Showers . . . . . . . . . . . . .66
417.4 Faucets and Fixture Fittings with Hose Connected Outlets . . . . .66
417.5 Separate Controls for Hot and Cold Water . . . . . . . . . . . . . . .66
417.6 Low-Pressure Water Dispenser . . . .66
417.7 Head Shampoo Sink Faucets . . . . .66
417.8 Footbaths and Pedicure Baths . . . .66
418.0 Floor Drains . . . . . . . . . . . . . . . . . .66
418.1 Application . . . . . . . . . . . . . . . . . . .66
418.2 Strainer . . . . . . . . . . . . . . . . . . . . . .66
418.3 Location of Floor Drains . . . . . . . . .67
418.4 Food Storage Areas . . . . . . . . . . . .67
418.5 Floor Slope . . . . . . . . . . . . . . . . . . .67
419.0 Food Waste Disposers . . . . . . . . . .67
419.1 Application . . . . . . . . . . . . . . . . . . .67
419.2 Drainage Connection . . . . . . . . . . .67
419.3 Water Supply . . . . . . . . . . . . . . . . .67
420.0 Sinks . . . . . . . . . . . . . . . . . . . . . . . .67
420.1 Application . . . . . . . . . . . . . . . . . . .67
420.2 Water Consumption . . . . . . . . . . . .67
420.3 Pre-Rinse Spray Valve . . . . . . . . . .67
TABLE OF CONTENTS
Table 420.3 Commercial Pre-Rinse Spray Valve Maximum Flow Rate . . . . . . .67
420.4 Waste Outlet . . . . . . . . . . . . . . . . . .67
421.0 Floor Sinks . . . . . . . . . . . . . . . . . . .67
421.1 Application . . . . . . . . . . . . . . . . . . .67
421.2 Strainers . . . . . . . . . . . . . . . . . . . . .67
422.0 Minimum Number of
Required Fixtures . . . . . . . . . . . . . .67
422.1 Fixture Count . . . . . . . . . . . . . . . . .67
422.2 Separate Facilities . . . . . . . . . . . . .68
422.3 Fixture Requirements for Special Occupancies . . . . . . . . . . .68
422.4 Toilet Facilities Serving Employees and Customers . . . . . .68
422.5 Toilet Facilities for Workers . . . . . .69
422.6 Water Closet Compartment . . . . . .69
422.7 Urinal Partitions . . . . . . . . . . . . . . .69
422.8 Cosmetology . . . . . . . . . . . . . . . . .69
422.9 Cosmetology Establishments . . . . .69
422.10 Commissaries Serving Mobile Food Preparation Units . . . . . . . . .69
422.11 Employee Lavatories in Food Establishments . . . . . . . . . . .69
Table 422.1 Minimum Plumbing Facilities . . . . .70
Table 4-1 Occupant Load Factor
[BSC and DSA-SS] . . . . . . . . . . . .75
Table 4-2 Minimum Plumbing Facilities
[OSHPD 1, 2, 3, 4 & 5] . . . . . . . . .76
CHAPTER 5 WATER HEATERS . . . . . . . . . . . .81
501.0 General . . . . . . . . . . . . . . . . . . . . . .83
501.1 Applicability . . . . . . . . . . . . . . . . . . .83
Table 501.1(1) Water Heaters . . . . . . . . . . . . . . . .83
501.2 California Energy Code Water Heating System Requirements . . . . . . . . . . . . . . . . .83
502.0 Permits . . . . . . . . . . . . . . . . . . . . . .83
502.1 General . . . . . . . . . . . . . . . . . . . . . .83
503.0 Inspection . . . . . . . . . . . . . . . . . . . .83
503.1 Inspection of Chimneys or Vents . . .83
503.2 Final Water Heater Inspection . . . .83
504.0 Water Heater Requirements . . . . . .83
504.1 Location . . . . . . . . . . . . . . . . . . . . .83
Table 501.1(2) First Hour Rating . . . . . . . . . . . . . .83
504.2 Vent . . . . . . . . . . . . . . . . . . . . . . . .84
504.3 Clearance . . . . . . . . . . . . . . . . . . . .84
504.4 Pressure-Limiting Devices . . . . . . .84
504.5 Temperature-Limiting Devices . . . .84
504.6 Temperature, Pressure, and Vacuum Relief Devices . . . . . . . . .84
504.7 Lead Content . . . . . . . . . . . . . . . . .84
505.0 Oil-Burning and Other Water Heaters . . . . . . . . . . . . . . . . . . . . . .84
505.1 Water Heaters . . . . . . . . . . . . . . . .84
505.2 Safety Devices . . . . . . . . . . . . . . . .84
505.3 Oil-Fired Water Heaters . . . . . . . . .84
505.4 Indirect-Fired Water Heaters . . . . .84
506.0 Air for Combustion and
Ventilation . . . . . . . . . . . . . . . . . . . .84
506.1 General . . . . . . . . . . . . . . . . . . . . . .84
506.2 Indoor Combustion Air . . . . . . . . . .85
506.3 Indoor Opening Size and Location . . . . . . . . . . . . . . . . . . . . .85
506.4 Outdoor Combustion Air . . . . . . . . .85
506.5 Combination Indoor and
Outdoor Combustion Air . . . . . . . . .87
506.6 Engineered Installations . . . . . . . . .87
506.7 Mechanical Combustion Air Supply . . . . . . . . . . . . . . . . . . . . . . .87
506.8 Louvers, Grilles, and Screens . . . .87
506.9 Combustion Air Ducts . . . . . . . . . . .87
507.0 Appliance and Equipment Installation Requirements . . . . . . . .88
507.1 Dielectric Insulator . . . . . . . . . . . . .88
507.2 Seismic Provisions . . . . . . . . . . . . .88
507.3 Appliance Support . . . . . . . . . . . . .88
507.4 Ground Support . . . . . . . . . . . . . . .88
507.5 Drainage Pan . . . . . . . . . . . . . . . . .88
507.6 Added or Converted
Equipment or Appliances . . . . . . . .88
507.7 Type of Gas(es) . . . . . . . . . . . . . . .88
507.8 Safety Shutoff Devices for Unlisted LP-Gas Appliance Used Indoors . . . . . . . . . . . . . . . . .89
507.9 Use of Air or Oxygen Under Pressure . . . . . . . . . . . . . . . . . . . . .89
507.10 Protection of Gas Appliances from Fumes or Gases other
than Products of Combustion . . . . .89
507.11 Process Air . . . . . . . . . . . . . . . . . . .89
507.12 Flammable Vapors . . . . . . . . . . . . .89
507.13 Installation in Residential Garages . . . . . . . . . . . . . . . . . . . . .89
507.14 Installation in Commercial Garages . . . . . . . . . . . . . . . . . . . . .89
507.15 Installation in Aircraft Hangars . . . .89
507.16 Venting of Flue Gases . . . . . . . . . .89
507.17 Extra Device or Attachment . . . . . .89
507.18 Addition to Existing System . . . . . .89
507.19 Avoiding Strain on Gas Piping . . . .89
507.20 Gas Appliance Pressure Regulators . . . . . . . . . . . . . . . . . . .89
507.21 Bleed Lines for Diaphragm-Type Valves . . . . . . . . . . . . . . . . . . . . . . .89
TABLE OF CONTENTS
507.22 Combination of Appliances and Equipment . . . . . . . . . . . . . . . .90
507.23 Installation Instructions . . . . . . . . . .90
507.24 Protection of Outdoor
Appliances . . . . . . . . . . . . . . . . . . .90
507.25 Accessibility for Service . . . . . . . . .90
507.26 Clearance to Combustible
Materials . . . . . . . . . . . . . . . . . . . . .90
508.0 Appliances on Roofs, in Attics or Under-Floor Spaces . . . . . . . . . .90
508.1 General . . . . . . . . . . . . . . . . . . . . . .90
508.2 Installation of Appliances on Roofs . . . . . . . . . . . . . . . . . . . . .90
508.3 Appliances on Roofs . . . . . . . . . . .90
508.4 Appliances in Attics and Under-Floor Spaces . . . . . . . . . . . .91
509.0 Venting of Appliances . . . . . . . . . . .91
509.1 Listing . . . . . . . . . . . . . . . . . . . . . . .91
509.2 Connection to Venting Systems . . .91
509.3 Minimum Safe Performance . . . . . .91
509.4 Type of Venting System to be Used . . . . . . . . . . . . . . . . . . . . .92
Table 509.4 Type of Venting System to be Used . . . . . . . . . . . . . . . . . . .92
509.5 Masonry, Metal, and Factory-Built Chimneys . . . . . . . . .93
509.6 Gas Vents . . . . . . . . . . . . . . . . . . . .94
Table 509.6.1 Roof Slope Heights . . . . . . . . . . . .95
509.7 Single-Wall Metal Pipe . . . . . . . . . .97
Table 509.7.3.4(1) Clearances for Connectors . . . . . . .97
Table 509.7.3.4(2) Reduction of Clearances with Specified Forms of Protection . . . .99
509.8 Through-the-Wall Vent Termination . . . . . . . . . . . . . . . . . .100
509.9 Condensation Drain . . . . . . . . . . .100
509.10 Vent Connectors for
Category I Appliances . . . . . . . . .100
Table 509.8.1 Through-the-Wall Direct-Vent Termination Clearances . . . . . . . .101
Table 509.10.1.3 Minimum Thickness for
Galvanized Steel Vent
Connectors for Low-Heat
Appliances . . . . . . . . . . . . . . . . . .102
Table 509.10.1.4 Minimum Thickness for Steel
Vent Connectors for
Medium-Heat Appliances . . . . . . .102
509.11 Vent Connectors for
Category II, Category III, and Category IV Appliances . . . . . . . .104
509.12 Appliances Requiring Draft Hoods . . . . . . . . . . . . . . . . . . . . . .104
509.13 Manually Operated Dampers . . . .104
509.14 Automatically Operated Vent Dampers . . . . . . . . . . . . . . . .104
509.15 Obstructions . . . . . . . . . . . . . . . . .104
510.0 Sizing of Category I Venting Systems . . . . . . . . . . . . . . . . . . . .104
510.1 Additional Requirements to Single Appliance Vent . . . . . . . . .104
510.2 Additional Requirements to Multiple-Appliance Vent . . . . . . . . .106
Table 510.2.1 Vent Connector Maximum
Length . . . . . . . . . . . . . . . . . . . . . .106
Table 510.1.2(1) Type B Double-Wall Gas Vent . . .110
Table 510.1.2(2) Type B Double-Wall Gas Vent . . .113
Table 510.1.2(3) Masonry Chimney . . . . . . . . . . . . .115
Table 510.1.2(4) Masonry Chimney . . . . . . . . . . . . .117
Table 510.1.2(5) Single-Wall Metal Pipe or Type B Asbestos-Cement Vent . . .119
Table 510.1.2(6) Exterior Masonry Chimney . . . . . .120
Table 510.2(1) Type B Double-Wall Vent . . . . . . .121
Table 510.2(2) Type B Double-Wall Vent . . . . . . .125
Table 510.2(3) Masonry Chimney . . . . . . . . . . . . .127
Table 510.2(4) Masonry Chimney . . . . . . . . . . . . .129
Table 510.2(5) Single-Wall Metal Pipe or Type B Asbestos-Cement Vent . .131
Table 510.2(6) Exterior Masonry Chimney . . . . . .131
Table 510.2(7) Exterior Masonry Chimney . . . . . .132
Table 510.2(8) Exterior Masonry Chimney . . . . . .133
Table 510.2(9) Exterior Masonry Chimney . . . . . .134
CHAPTER 6 WATER SUPPLY AND
DISTRIBUTION . . . . . . . . . . . . . .135
601.0 General . . . . . . . . . . . . . . . . . . . . .137
601.1 Applicability . . . . . . . . . . . . . . . . . .137
601.2 Water Supply and Flushing . . . . .137
601.3 Identification of a Potable and Nonpotable Water System . . . . . .137
Table 601.3.2 Minimum Length of Color Field and Size of Letters . . . . . . .138
601.4 Schools of Cosmetology and Cosmetological Establishments . .138
601.5 Meat and Poultry Processing Plants . . . . . . . . . . . . . . . . . . . . . .138
601.6 Collection Centers and
Facilities . . . . . . . . . . . . . . . . . . . .139
601.7 Renderers . . . . . . . . . . . . . . . . . . .139
601.8 Horse Meat and Pet Food
Establishments . . . . . . . . . . . . . . .139
602.0 Unlawful Connections . . . . . . . . . .139
602.1 Prohibited Installation . . . . . . . . . .139
602.2 Cross-Contamination . . . . . . . . . .139
602.3 Backflow Prevention . . . . . . . . . . .139
TABLE OF CONTENTS
602.4 Approval by Authority . . . . . . . . . .139
603.0 Cross-Connection Control . . . . . .139
603.1 General . . . . . . . . . . . . . . . . . . . . .139
603.2 Approval of Devices or Assemblies . . . . . . . . . . . . . . . . . .139
603.3 Backflow Prevention Devices, Assemblies, and Methods . . . . . .140
603.4 General Requirements . . . . . . . . .140
603.5 Specific Requirements . . . . . . . . .141
Table 603.2 Backflow Prevention Devices, Assemblies, and Methods . . . . . .142
Table 603.3.1 Minimum Air Gaps for Water Distribution . . . . . . . . . . . . . . . . . .144
604.0 Materials . . . . . . . . . . . . . . . . . . . .146
604.1 Pipe, Tube, and Fittings . . . . . . . .146
604.2 Lead Content . . . . . . . . . . . . . . . .147
604.3 Copper or Copper Alloy Tube . . .147
604.4 Hard-Drawn Copper or Copper Alloy Tubing . . . . . . . . . . . . . . . . .147
604.5 Flexible Connectors . . . . . . . . . . .147
604.6 Cast-Iron Fittings . . . . . . . . . . . . .147
604.7 Malleable Iron Fittings . . . . . . . . .147
604.8 Previously Used Piping and Tubing . . . . . . . . . . . . . . . . . . . . . .147
604.9 Epoxy Coating . . . . . . . . . . . . . . .147
604.10 Plastic Materials . . . . . . . . . . . . . .147
Table 604.1 Materials for Building Supply and Water Distribution Piping and Fittings . . . . . . . . . . . . . . . . . .148
604.11 Solder . . . . . . . . . . . . . . . . . . . . . .149
604.12 Flexible Corrugated Connectors . .149
604.13 Water Heater Connectors . . . . . . .149
605.0 Joints and Connections . . . . . . . .149
605.1 Copper or Copper Alloy Pipe, Tubing, and Joints . . . . . . . . . . . .149
605.2 CPVC Plastic Pipe and Joints . . .150
605.3 CPVC/AL/CPVC Plastic Pipe and Joints . . . . . . . . . . . . . . . . . . .150
605.4 Ductile Iron Pipe and Joints . . . . .150
605.5 Galvanized Steel Pipe and Joints . . . . . . . . . . . . . . . . . . . . . .151
605.6 PE Plastic Pipe/Tubing and Joints . . . . . . . . . . . . . . . . . . . . . .151
605.7 PE-AL-PE Plastic Pipe/Tubing and Joints . . . . . . . . . . . . . . . . . . .151
605.8 PE-RT . . . . . . . . . . . . . . . . . . . . . .151
605.9 PEX Plastic Tubing and Joints . . .151
605.10 PEX-AL-PEX Plastic Tubing and Joints . . . . . . . . . . . . . . . . . . .152
605.11 Polypropylene (PP) Piping and Joints . . . . . . . . . . . . . . . . . . .152
605.12 PVC Plastic Pipe and Joints . . . . .152
605.13 Stainless Steel Pipe and Joints . . .152
605.14 Slip Joints . . . . . . . . . . . . . . . . . . .153
605.15 Dielectric Unions . . . . . . . . . . . . . .153
605.16 Joints Between Various
Materials . . . . . . . . . . . . . . . . . . . .153
606.0 Valves . . . . . . . . . . . . . . . . . . . . . .153
606.1 General . . . . . . . . . . . . . . . . . . . . .153
606.2 Fullway Valve . . . . . . . . . . . . . . . .153
606.3 Multidwelling Units . . . . . . . . . . . .153
606.4 Multiple Openings . . . . . . . . . . . . .153
606.5 Control Valve . . . . . . . . . . . . . . . .153
606.6 Accessible . . . . . . . . . . . . . . . . . .153
606.7 Multiple Fixtures . . . . . . . . . . . . . .153
606.9 Check Valve Required . . . . . . . . .153
606.10 Leak Detection Devices . . . . . . . .154
607.0 Potable Water Supply Tanks . . . .154
607.1 General . . . . . . . . . . . . . . . . . . . . .154
607.2 Private Well Water Tanks . . . . . . .154
607.3 Potable Water Tanks . . . . . . . . . .154
607.4 Venting . . . . . . . . . . . . . . . . . . . . .154
607.5 Overflow . . . . . . . . . . . . . . . . . . . .154
607.6 Valves . . . . . . . . . . . . . . . . . . . . . .154
608.0 Water Pressure, Pressure Regulators, Pressure Relief Valves, and Vacuum Relief
Valves . . . . . . . . . . . . . . . . . . . . . .154
608.1 Inadequate Water Pressure . . . . .154
608.2 Excessive Water Pressure . . . . . .154
608.3 Expansion Tanks, and Combination Temperature and Pressure-Relief Valves . . . . .154
608.4 Pressure Relief Valves . . . . . . . . .154
608.5 Discharge Piping . . . . . . . . . . . . .154
608.6 Water-Heating Devices . . . . . . . . .155
608.7 Vacuum Relief Valves . . . . . . . . .155
609.0 Installation, Testing, Unions, and Location . . . . . . . . . . . . . . . . .155
609.1 Installation . . . . . . . . . . . . . . . . . .155
609.2 Trenches . . . . . . . . . . . . . . . . . . . .155
609.3 Under Concrete Slab . . . . . . . . . .155
609.4 Testing . . . . . . . . . . . . . . . . . . . . .155
609.5 Unions . . . . . . . . . . . . . . . . . . . . .155
609.6 Location . . . . . . . . . . . . . . . . . . . .155
609.7 Abutting Lot . . . . . . . . . . . . . . . . .155
609.8 Pumps . . . . . . . . . . . . . . . . . . . . .155
609.9 Low-Pressure Cutoff Required on Booster Pumps for Water Distribution Systems . . . . . . . . . . .156
TABLE OF CONTENTS
609.10 Disinfection of Potable Water System . . . . . . . . . . . . . . . . . . . . .156
609.11 Water Hammer . . . . . . . . . . . . . . .156
609.12 Pipe Insulation . . . . . . . . . . . . . . .156
610.0 Size of Potable Water Piping . . . .156
610.1 Size . . . . . . . . . . . . . . . . . . . . . . . .156
610.2 Pressure Loss . . . . . . . . . . . . . . . .156
610.3 Quantity of Water . . . . . . . . . . . . .157
610.4 Sizing Water Supply and Distribution Systems . . . . . . . . . . .157
610.5 Sizing per Appendices A, C, and M . . . . . . . . . . . . . . . . .157
610.6 Friction and Pressure Loss . . . . . .157
610.7 Conditions for Using Table 610.4 . . . . . . . . . . . . . . . . . .157
610.8 Size of Meter and Building Supply Pipe Using Table 610.4 . .157
610.9 Size of Branches . . . . . . . . . . . . .157
610.10 Sizing for Flushometer Valves . . .157
Table 610.10 Flushometer Fixture Units for Water Sizing Using Table 610.3 . . . . . . . . . . . . . . . . . .157
Table 610.3 Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes . . . . . . . . . . . .158
Table 610.4 Fixture Unit Table for
Determining Water Pipe and Meter Sizes . . . . . . . . . . . . . .159
610.11 Sizing Systems for Flushometer Tanks . . . . . . . . . . . .160
610.12 Sizing for Velocity . . . . . . . . . . . . .160
610.13 Exceptions . . . . . . . . . . . . . . . . . .160
611.0 Drinking Water Treatment Units . . . . . . . . . . . . . . . . . . . . . . .160
611.1 Application . . . . . . . . . . . . . . . . . .160
611.2 Air Gap Discharge . . . . . . . . . . . .160
611.3 Connection Tubing . . . . . . . . . . . .160
611.4 Sizing of Residential Softeners . . .160
612.0 Residential Fire Sprinkler Systems . . . . . . . . . . . . . . . . . . . .160
612.1 Installation . . . . . . . . . . . . . . . . . .160
Table 611.1 Drinking Water Treatment Units . . . . . . . . . . . . . . . . . . . . . . .161
Table 611.4 Sizing of Residential Water Softeners . . . . . . . . . . . . . . . . . . .161
613.0 Domestic Hot-Water Distribution Systems for Health Facilities and Clinics . . . . . . . . . . . . . . . . . .161
Table 613.1 Hot Water Use . . . . . . . . . . . . . . . . .161
614.0 Dialysis Water-Distribution Systems . . . . . . . . . . . . . . . . . . . . . .162
615.0 Identification of Potable and
Nonpotable Water Lines . . . . . . . . .162
615.1 Uses Not Permitted . . . . . . . . . . . . .162
616.0 Emergency Water Supply . . . . . . . .162
CHAPTER 7 SANITARY DRAINAGE . . . . . . . .163
PART I Drainage Systems . . . . . . . . . . .165
701.0 General . . . . . . . . . . . . . . . . . . . . .165
701.1 Applicability . . . . . . . . . . . . . . . . . .165
701.2 Drainage Piping . . . . . . . . . . . . . .165
701.3 Drainage Fittings . . . . . . . . . . . . .165
701.4 Continuous Wastes . . . . . . . . . . .165
701.5 Lead . . . . . . . . . . . . . . . . . . . . . . .165
701.6 Caulking Ferrules . . . . . . . . . . . . .165
701.7 Soldering Bushings . . . . . . . . . . . .165
Table 701.6 Caulking Ferrules . . . . . . . . . . . . .165
Table 701.7 Soldering Bushings . . . . . . . . . . . .165
702.0 Fixture Unit Equivalents . . . . . . . .165
702.1 Trap Size . . . . . . . . . . . . . . . . . . .165
Table 701.2 Materials for Drain, Waste, Vent Pipe and Fittings . . . . . . . . .166
Table 702.1 Drainage Fixture Unit Values (DFU) . . . . . . . . . . . . . . . .167
Table 702.1(1) Maximum Drainage Fixture Units for a Trap and Trap Arm . . .168
702.2 Intermittent Flow . . . . . . . . . . . . . .168
Table 702.2 Discharge Capacity in Gallons Per Minute for
Intermittent Flow Only . . . . . . . . .168
702.3 Continuous Flow . . . . . . . . . . . . . .168
703.0 Size of Drainage Piping . . . . . . . .168
703.1 Minimum Size . . . . . . . . . . . . . . . .168
703.2 Maximum Number of Fixture
Units . . . . . . . . . . . . . . . . . . . . . . .168
703.3 Sizing per Appendix C . . . . . . . . .168
704.0 Fixture Connections (Drainage) . .168
704.1 Inlet Fittings . . . . . . . . . . . . . . . . .168
704.2 Single Vertical Drainage Pipe . . . .168
704.3 Commercial Sinks . . . . . . . . . . . . .168
Table 703.2 Maximum Unit Loading and Maximum Length of Drainage and Vent Piping . . . . . . . . . . . . . .169
705.0 Joints and Connections . . . . . . . .169
705.1 ABS and ABS Co-Extruded
Plastic Pipe and Joints . . . . . . . . .169
705.2 Cast-Iron Pipe and Joints . . . . . . .169
705.3 Copper or Copper Alloy Pipe (DWV) and Joints . . . . . . . . .170
705.4 Galvanized Steel Pipe and Joints . . . . . . . . . . . . . . . . . . .170
705.5 Polyethylene (PE) Sewer Pipe . . .170
TABLE OF CONTENTS
705.6 PVC and PVC Co-Extruded
Plastic Pipe and Joining Methods . . . . . . . . . . . . . . . . . . . .171
705.7 Stainless Steel Pipe and Joints . . .171
705.8 Vitrified Clay Pipe and Joints . . . .171
705.9 Special Joints . . . . . . . . . . . . . . . .171
705.10 Joints Between
Various Materials . . . . . . . . . . . . .171
706.0 Changes in Direction of Drainage Flow . . . . . . . . . . . . . . .172
706.1 Approved Fittings . . . . . . . . . . . . .172
706.2 Horizontal to Vertical . . . . . . . . . .172
706.3 Horizontal to Horizontal . . . . . . . .172
706.4 Vertical to Horizontal . . . . . . . . . .172
707.0 Cleanouts . . . . . . . . . . . . . . . . . . .172
707.1 Plug . . . . . . . . . . . . . . . . . . . . . . .172
Table 707.1 Cleanouts . . . . . . . . . . . . . . . . . . .172
707.2 Approved . . . . . . . . . . . . . . . . . . .172
Table 707.2 Cleanout Materials for Drain, Waste, and Vent . . . . . . . . . . . . . .172
707.3 Watertight and Gastight . . . . . . . .172
707.4 Location . . . . . . . . . . . . . . . . . . . .172
707.5 Cleaning . . . . . . . . . . . . . . . . . . . .173
707.6 Extension . . . . . . . . . . . . . . . . . . .173
707.7 Interceptor . . . . . . . . . . . . . . . . . .173
707.8 Access . . . . . . . . . . . . . . . . . . . . .173
707.9 Clearance . . . . . . . . . . . . . . . . . . .173
707.10 Fittings . . . . . . . . . . . . . . . . . . . . .173
707.11 Pressure Drainage Systems . . . . .173
707.12 Countersunk Cleanout Plugs . . . .173
707.13 Hubless Blind Plugs . . . . . . . . . . .173
707.14 Trap Arms . . . . . . . . . . . . . . . . . . .173
708.0 Grade of Horizontal Drainage Piping . . . . . . . . . . . . . . . . . . . . . .173
708.1 General . . . . . . . . . . . . . . . . . . . . .173
709.0 Gravity Drainage Required . . . . . .173
709.1 General . . . . . . . . . . . . . . . . . . . . .173
710.0 Drainage of Fixtures Located Below the Next Upstream Manhole or Below the Main
Sewer Level . . . . . . . . . . . . . . . . .173
710.1 Backflow Protection . . . . . . . . . . .173
710.2 Sewage Discharge . . . . . . . . . . . .173
710.3 Sewage Ejector and Pumps . . . . .173
710.4 Discharge Line . . . . . . . . . . . . . . .174
710.5 Size of Building Drains and Sewers . . . . . . . . . . . . . . . . . . . . .174
710.6 Backwater Valves . . . . . . . . . . . . .174
710.7 Drainage and Venting Systems . . .174
710.8 Sump and Receiving Tank Construction . . . . . . . . . . . . . . . . .174
710.9 Alarm . . . . . . . . . . . . . . . . . . . . . .174
710.10 Sump and Receiving Tank Covers and Vents . . . . . . . . . . . . .174
710.11 Air Tanks . . . . . . . . . . . . . . . . . . .174
710.12 Grinder Pump Ejector . . . . . . . . . .174
710.13 Macerating Toilet Systems and Pumped Waste Systems . . . .174
711.0 Suds Relief . . . . . . . . . . . . . . . . . .175
711.1 General . . . . . . . . . . . . . . . . . . . . .175
712.0 Testing . . . . . . . . . . . . . . . . . . . . .175
712.1 Media . . . . . . . . . . . . . . . . . . . . . .175
712.2 Water Test . . . . . . . . . . . . . . . . . .175
712.3 Air Test . . . . . . . . . . . . . . . . . . . . .175
PART II Building Sewers . . . . . . . . . . . . .175
713.0 Sewer Required . . . . . . . . . . . . . .175
713.1 Where Required . . . . . . . . . . . . . .175
713.2 Private Sewage Disposal System . . . . . . . . . . . . . . . . . . . . .175
713.3 Public Sewer . . . . . . . . . . . . . . . . .175
713.4 Public Sewer Availability . . . . . . .175
713.5 Permit . . . . . . . . . . . . . . . . . . . . . .175
713.6 Lot . . . . . . . . . . . . . . . . . . . . . . . . .175
713.7 Installation . . . . . . . . . . . . . . . . . .175
714.0 Damage to Public Sewer or Private Sewage Disposal System . . . . . . . . . . . . . . . . . . . . .175
714.1 Unlawful Practices . . . . . . . . . . . .175
714.2 Prohibited Water Discharge . . . . .176
714.3 Prohibited Sewer Connection . . . .176
714.4 Commercial Food Waste
Disposer . . . . . . . . . . . . . . . . . . . .176
714.5 Tanks . . . . . . . . . . . . . . . . . . . . . .176
715.0 Building Sewer Materials . . . . . . .176
715.1 Materials . . . . . . . . . . . . . . . . . . . .176
715.2 Joining Methods and Materials . . .176
715.3 Existing Sewers . . . . . . . . . . . . . .176
716.0 Markings . . . . . . . . . . . . . . . . . . . .176
716.1 General . . . . . . . . . . . . . . . . . . . . .176
717.0 Size of Building Sewers . . . . . . . .176
717.1 General . . . . . . . . . . . . . . . . . . . . .176
Table 717.1 Maximum/Minimum Fixture
Unit Loading on Building Sewer Piping . . . . . . . . . . . . . . . .176
717.2 Meat and Poultry Processing Plants . . . . . . . . . . . . . . . . . . . . . .176
718.0 Grade, Support, and Protection of Building Sewers . . .176
718.1 Slope . . . . . . . . . . . . . . . . . . . . . .176
TABLE OF CONTENTS
718.2 Support . . . . . . . . . . . . . . . . . . . . .176
718.3 Protection from Damage . . . . . . .176
719.0 Cleanouts . . . . . . . . . . . . . . . . . . .177
719.1 Locations . . . . . . . . . . . . . . . . . . .177
719.2 No Additional Cleanouts . . . . . . . .177
719.3 Building Sewer Cleanouts . . . . . .177
719.4 Cleaning . . . . . . . . . . . . . . . . . . . .177
719.5 Access . . . . . . . . . . . . . . . . . . . . .177
719.6 Manholes . . . . . . . . . . . . . . . . . . .177
720.0 Sewer and Water Pipes . . . . . . . .177
720.1 General . . . . . . . . . . . . . . . . . . . . .177
721.0 Location . . . . . . . . . . . . . . . . . . . .177
721.1 Building Sewer . . . . . . . . . . . . . . .177
Table 721.1 Minimum Horizontal Distance Required from Building Sewer . . . .177
721.2 Abutting Lot . . . . . . . . . . . . . . . . .177
722.0 Abandoned Sewers and Sewage Disposal Facilities . . . . . .177
722.1 Building (House) Sewer . . . . . . . .177
722.2 Cesspools, Septic Tanks, and Seepage Pits . . . . . . . . . . . . .178
722.3 Filling . . . . . . . . . . . . . . . . . . . . . .178
722.4 Ownership . . . . . . . . . . . . . . . . . .178
722.5 Disposal Facilities . . . . . . . . . . . . .178
723.0 Building Sewer Test . . . . . . . . . . .178
723.1 General . . . . . . . . . . . . . . . . . . . . .178
724.0 Meat and Poultry Processing Plant Drainage . . . . . . . . . . . . . . .178
725.0 Collection Center and
Facilities Drainage . . . . . . . . . . . .178
726.0 Drainage and Plumbing, General . . . . . . . . . . . . . . . . . . . . .178
727.0 Emergency Sanitary Drainage . . .178
CHAPTER 8 INDIRECT WASTES . . . . . . . . . .179
801.0 General . . . . . . . . . . . . . . . . . . . . .181
801.1 Applicability . . . . . . . . . . . . . . . . . .181
801.2 Air Gap or Air Break Required . . .181
801.3 Food and Beverage Handling Establishments . . . . . . .181
801.4 Bar and Fountain Sink Traps . . . .181
801.5 Connections from Water Distribution System . . . . . . . . . . . .181
801.6 Sterilizers . . . . . . . . . . . . . . . . . . .181
801.7 Drip or Drainage Outlets . . . . . . . .181
802.0 Approvals . . . . . . . . . . . . . . . . . . .181
802.1 General . . . . . . . . . . . . . . . . . . . . .181
803.0 Indirect Waste Piping . . . . . . . . . .181
803.1 Materials . . . . . . . . . . . . . . . . . . . .181
803.2 Copper and Copper Alloys . . . . . .181
803.3 Pipe Size and Length . . . . . . . . . .181
804.0 Indirect Waste Receptors . . . . . . .182
804.1 Standpipe Receptors . . . . . . . . . .182
805.0 Pressure Drainage Connections . . . . . . . . . . . . . . . . .182
805.1 General . . . . . . . . . . . . . . . . . . . . .182
806.0 Sterile Equipment . . . . . . . . . . . . .182
806.1 General . . . . . . . . . . . . . . . . . . . . .182
807.0 Appliances . . . . . . . . . . . . . . . . . .182
807.1 Non-Classed Apparatus . . . . . . . .182
807.2 Undiluted Condensate Waste . . . .182
807.3 Domestic Dishwashing Machine . . . . . . . . . . . . . . . . . . . .182
808.0 Cooling Water . . . . . . . . . . . . . . . .182
808.1 General . . . . . . . . . . . . . . . . . . . . .182
809.0 Drinking Fountains . . . . . . . . . . . .182
809.1 General . . . . . . . . . . . . . . . . . . . . .182
810.0 Steam and Hot Water Drainage Condensers and Sumps . . . . . . . .182
810.1 High-Temperature Discharge . . . .182
Table 810.1 Pipe Connections in Blowoff Condensers and Sumps . . . . . . . .183
810.2 Sumps, Condensers, and Intercepting Tanks . . . . . . . . . . . .183
810.3 Cleaning . . . . . . . . . . . . . . . . . . . .183
810.4 Strainers . . . . . . . . . . . . . . . . . . . .183
811.0 Chemical Wastes . . . . . . . . . . . . .183
811.1 Pretreatment . . . . . . . . . . . . . . . . .183
811.2 Waste and Vent Pipes . . . . . . . . .183
811.3 Joining Materials . . . . . . . . . . . . . .183
811.4 Access . . . . . . . . . . . . . . . . . . . . .183
811.5 Permanent Record . . . . . . . . . . . .183
811.6 Chemical Vent . . . . . . . . . . . . . . .183
811.7 Discharge . . . . . . . . . . . . . . . . . . .183
811.8 Diluted Chemicals . . . . . . . . . . . . .183
812.0 Clear Water Wastes . . . . . . . . . . .183
812.1 General . . . . . . . . . . . . . . . . . . . . .183
813.0 Swimming Pools . . . . . . . . . . . . . .183
813.1 General . . . . . . . . . . . . . . . . . . . . .183
814.0 Condensate Waste and Control . . .183
814.1 Condensate Disposal . . . . . . . . . .183
814.2 Condensate Control . . . . . . . . . . .184
814.3 Condensate Waste Pipe Material and Sizing . . . . . . . . . . . .184
Table 814.3 Minimum Condensate Pipe Size . . . . . . . . . . . . . . . . . . .184
814.4 Appliance Condensate Drains . . .184
814.5 Point of Discharge . . . . . . . . . . . .184
814.6 Condensate Waste from
Air-Conditioning Coils . . . . . . . . . .185
814.7 Plastic Fittings . . . . . . . . . . . . . . .185
TABLE OF CONTENTS
CHAPTER 9 VENTS . . . . . . . . . . . . . . . . . . . . .187
901.0 General . . . . . . . . . . . . . . . . . . . . .189
901.1 Applicability . . . . . . . . . . . . . . . . . .189
901.2 Vents Required . . . . . . . . . . . . . . .189
901.3 Trap Seal Protection . . . . . . . . . . .189
902.0 Vents Not Required . . . . . . . . . . .189
902.1 Interceptor . . . . . . . . . . . . . . . . . .189
902.2 Bars, Soda Fountains, and Counter . . . . . . . . . . . . . . . . . . . . .189
903.0 Materials . . . . . . . . . . . . . . . . . . . .189
903.1 Applicable Standards . . . . . . . . . .189
903.2 Use of Copper or Copper Alloy Tubing . . . . . . . . . . . . . . . . .189
903.3 Changes in Direction . . . . . . . . . .189
904.0 Size of Vents . . . . . . . . . . . . . . . .189
904.1 Size . . . . . . . . . . . . . . . . . . . . . . . .189
904.2 Length . . . . . . . . . . . . . . . . . . . . . .189
905.0 Vent Pipe Grades and Connections . . . . . . . . . . . . . . . . .190
905.1 Grade . . . . . . . . . . . . . . . . . . . . . .190
905.2 Horizontal Drainage Pipe . . . . . . .190
905.3 Vent Pipe Rise . . . . . . . . . . . . . . .190
905.4 Roof Termination . . . . . . . . . . . . .190
905.5 Location of Opening . . . . . . . . . . .190
905.6 Common Vertical Pipe . . . . . . . . .190
906.0 Vent Termination . . . . . . . . . . . . .190
906.1 Roof Termination . . . . . . . . . . . . .190
906.2 Clearance . . . . . . . . . . . . . . . . . . .190
906.3 Use of Roof . . . . . . . . . . . . . . . . .190
906.4 Outdoor Installations . . . . . . . . . . .190
906.5 Joints . . . . . . . . . . . . . . . . . . . . . .190
906.6 Lead . . . . . . . . . . . . . . . . . . . . . . .190
906.7 Frost or Snow Closure . . . . . . . . .190
907.0 Vent Stacks and Relief Vents . . . .190
907.1 Drainage Stack . . . . . . . . . . . . . . .190
907.2 Yoke Vent . . . . . . . . . . . . . . . . . . .190
908.0 Wet Venting . . . . . . . . . . . . . . . . .190
908.1 Vertical Wet Venting . . . . . . . . . . .190
908.2 Horizontal Wet Venting for a Bathroom Group . . . . . . . . . . . . . .191
909.0 Special Venting for Island Fixtures . . . . . . . . . . . . . . . . . . . . .191
909.1 General . . . . . . . . . . . . . . . . . . . . .191
910.0 Combination Waste and Vent
Systems . . . . . . . . . . . . . . . . . . . .191
910.1 Where Permitted . . . . . . . . . . . . . .191
910.2 Approval . . . . . . . . . . . . . . . . . . . .191
910.3 Vents . . . . . . . . . . . . . . . . . . . . . .191
910.4 Connections and Size . . . . . . . . .191
910.5 Vertical Waste Pipe . . . . . . . . . . .191
910.6 Cleanouts . . . . . . . . . . . . . . . . . . .191
910.7 Fixtures . . . . . . . . . . . . . . . . . . . . .191
911.0 Circuit Venting . . . . . . . . . . . . . . .191
911.1 Circuit Vent Permitted . . . . . . . . .191
911.2 Circuit Vent Size and
Connection . . . . . . . . . . . . . . . . . .192
911.3 Relief Vent . . . . . . . . . . . . . . . . . .192
911.4 Slope and Size of Horizontal Branch . . . . . . . . . . . . . . . . . . . . .192
911.5 Additional Fixtures . . . . . . . . . . . .192
912.0 Engineered Vent System . . . . . . .192
912.1 General . . . . . . . . . . . . . . . . . . . . .192
912.2 Minimum Requirements . . . . . . . .192
CHAPTER 10 TRAPS AND
INTERCEPTORS . . . . . . . . . . . . .193
1001.0 General . . . . . . . . . . . . . . . . . . . . .195
1001.1 Applicability . . . . . . . . . . . . . . . . . .195
1001.2 Where Required . . . . . . . . . . . . . .195
1002.0 Traps Protected by Vent Pipes . .195
1002.1 Vent Pipes . . . . . . . . . . . . . . . . . .195
1002.2 Fixture Traps . . . . . . . . . . . . . . . .195
1002.3 Change of Direction . . . . . . . . . . .195
1002.4 Vent Pipe Opening . . . . . . . . . . . .195
1003.0 Traps – Described . . . . . . . . . . . .195
1003.1 General Requirements . . . . . . . . .195
Table 1002.2 Horizontal Lengths of Trap Arms . . . . . . . . . . . . . . . . . . . . . . .195
1003.2 Slip Joint Fittings . . . . . . . . . . . . .195
1003.3 Size . . . . . . . . . . . . . . . . . . . . . . . .195
1004.0 Traps . . . . . . . . . . . . . . . . . . . . . .196
1004.1 Prohibited . . . . . . . . . . . . . . . . . . .196
1004.2 Movable Parts . . . . . . . . . . . . . . . .196
1005.0 Trap Seals . . . . . . . . . . . . . . . . . .196
1005.1 General . . . . . . . . . . . . . . . . . . . . .196
1006.0 Floor Drain Traps . . . . . . . . . . . . .196
1006.1 General . . . . . . . . . . . . . . . . . . . . .196
1007.0 Trap Seal Protection . . . . . . . . . . .196
1007.1 General . . . . . . . . . . . . . . . . . . . . .196
1007.2 Trap Seal Primers . . . . . . . . . . . .196
1008.0 Building Traps . . . . . . . . . . . . . . . .196
1008.1 General . . . . . . . . . . . . . . . . . . . . .196
1009.0 Interceptors (Clarifiers) and Separators . . . . . . . . . . . . . . . . . .196
1009.1 Where Required . . . . . . . . . . . . . .196
Table 1009.1 Approved Interceptors (Clarifiers) . .196
1009.2 Approval . . . . . . . . . . . . . . . . . . . .196
1009.3 Design . . . . . . . . . . . . . . . . . . . . .196
TABLE OF CONTENTS
1009.4 Relief Vent . . . . . . . . . . . . . . . . . .196
1009.5 Location . . . . . . . . . . . . . . . . . . . .196
1009.6 Maintenance of Interceptors . . . . .196
1009.7 Discharge . . . . . . . . . . . . . . . . . . .196
1010.0 Slaughterhouses, Packing Establishments, etc . . . . . . . . . . .196
1010.1 General . . . . . . . . . . . . . . . . . . . . .196
1010.2 Meat and Poultry Processing Plants . . . . . . . . . . . . . . . . . . . . . .197
1010.3 Collection Centers and
Facilities . . . . . . . . . . . . . . . . . . . .197
1010.4 Horse Meat and Pet Food
Establishments . . . . . . . . . . . . . . .197
1010.5 Draining and Plumbing . . . . . . . .197
1011.0 Minimum Requirements for Auto Wash Racks . . . . . . . . . . . . .197
1011.1 General . . . . . . . . . . . . . . . . . . . . .197
1012.0 Commercial and Industrial
Laundries . . . . . . . . . . . . . . . . . . .197
1012.1 General . . . . . . . . . . . . . . . . . . . . .197
1013.0 Bottling Establishments . . . . . . . .197
1013.1 General . . . . . . . . . . . . . . . . . . . . .197
1014.0 Grease Interceptors . . . . . . . . . . .197
1014.1 General . . . . . . . . . . . . . . . . . . . . .197
1014.2 Hydromechanical Grease Interceptors . . . . . . . . . . . . . . . . . .198
Table 1014.2.1 Hydromechanical Grease Interceptor Sizing Using Gravity Flow Rates . . . . . . . . . . . .198
1014.3 Gravity Grease Interceptors . . . . .198
Table 1014.3.6 Gravity Grease Interceptor Sizing . . . . . . . . . . . . . . . . . . . . . .199
1015.0 FOG (Fats, Oils, and Greases) Disposal System . . . . . . . . . . . . . .199
1015.1 Purpose . . . . . . . . . . . . . . . . . . . .199
1015.2 Components, Materials, and Equipment . . . . . . . . . . . . . . . . . .200
1015.3 Sizing and Installation . . . . . . . . .200
1015.4 Performance . . . . . . . . . . . . . . . . .200
1016.0 Sand Interceptors . . . . . . . . . . . . .200
1016.1 Discharge . . . . . . . . . . . . . . . . . . .200
1016.2 Authority Having Jurisdiction . . . .200
1016.3 Construction and Size . . . . . . . . .200
1016.4 Separate Use . . . . . . . . . . . . . . . .200
1017.0 Oil and Flammable Liquid Interceptors . . . . . . . . . . . . . . . . . .200
1017.1 Interceptors Required . . . . . . . . . .200
1017.2 Interceptor Design Alternatives . . .200
1017.3 Interceptor Details . . . . . . . . . . . .200
1017.4 Design of Interceptors . . . . . . . . .200
CHAPTER 11 STORM DRAINAGE . . . . . . . . . .203
1101.0 General . . . . . . . . . . . . . . . . . . . . .205
1101.1 Applicability . . . . . . . . . . . . . . . . . .205
1101.2 Where Required . . . . . . . . . . . . . .205
1101.3 Storm Water Drainage to Sanitary Sewer Prohibited . . . . . .205
1101.4 Material Uses . . . . . . . . . . . . . . . .205
Table 1101.4.6 Materials for Subsoil Drainpipe and Fittings . . . . . . . . . . . . . . . . . .205
1101.5 Expansion Joints Required . . . . . .205
1101.6 Subsoil Drains . . . . . . . . . . . . . . .205
1101.7 Building Subdrains . . . . . . . . . . . .206
1101.8 Areaway Drains . . . . . . . . . . . . . .206
1101.9 Window Areaway Drains . . . . . . .206
1101.10 Filling Stations and Motor Vehicle Washing Establishments . . . . . . . . . . . . . . .206
1101.11 Paved Areas . . . . . . . . . . . . . . . . .206
1101.12 Roof Drainage . . . . . . . . . . . . . . .206
1101.13 Cleanouts . . . . . . . . . . . . . . . . . . .207
1101.14 Rainwater Sumps . . . . . . . . . . . . .207
1101.15 Traps on Storm Drains and Leaders . . . . . . . . . . . . . . . . . . . . .207
1101.16 Leaders, Conductors, and
Connections . . . . . . . . . . . . . . . . .207
1102.0 Roof Drains . . . . . . . . . . . . . . . . . .207
1102.1 Applications . . . . . . . . . . . . . . . . .207
1102.2 Dome Strainers Required . . . . . . .207
1102.3 Roof Drain Flashings . . . . . . . . . .207
1103.0 Size of Leaders, Conductors,
and Storm Drains . . . . . . . . . . . . .207
1103.1 Vertical Conductors and
Leaders . . . . . . . . . . . . . . . . . . . . .207
1103.2 Size of Horizontal Storm
Drains and Sewers . . . . . . . . . . . .207
1103.3 Size of Roof Gutters . . . . . . . . . . .207
1103.4 Side Walls Draining onto a Roof . . . . . . . . . . . . . . . . . .207
Table 1103.1 Sizing Roof Drains, Leaders, and Vertical Rainwater Piping . . .208
1104.0 Values for Continuous Flow . . . . .208
1104.1 General . . . . . . . . . . . . . . . . . . . . .208
1105.0 Controlled-Flow Roof
Drainage . . . . . . . . . . . . . . . . . . . .208
1105.1 Application . . . . . . . . . . . . . . . . . .208
Table 1105.1(1) Controlled-Flow Maximum Roof Water Depth . . . . . . . . . . . . .209
Table 1105.1(2) Distance of Scupper Bottoms Above Roof . . . . . . . . . . . . . . . . . .209
TABLE OF CONTENTS
1105.2 Setback Roofs . . . . . . . . . . . . . . .209
1106.0 Engineered Storm Drainage System . . . . . . . . . . . . . . . . . . . . .209
1106.1 General . . . . . . . . . . . . . . . . . . . . .209
1106.2 Siphonic Roof Drainage Systems . . . . . . . . . . . . . . . . . . . .209
1106.3 Siphonic Roof Drains . . . . . . . . . .209
1107.0 Testing . . . . . . . . . . . . . . . . . . . . .209
1107.1 Testing Required . . . . . . . . . . . . .209
1107.2 Methods of Testing Storm Drainage Systems . . . . . . . . . . . .209
Table 1103.2 Sizing of Horizontal Rainwater Piping . . . . . . . . . . . . .210
Table 1103.3 Size of Gutters . . . . . . . . . . . . . . .211
CHAPTER 12 FUEL GAS PIPING . . . . . . . . . . .213
1201.0 General . . . . . . . . . . . . . . . . . . . . .215
1201.1 Applicability . . . . . . . . . . . . . . . . . .215
1202.0 Coverage of Piping System . . . . .215
1202.1 General . . . . . . . . . . . . . . . . . . . . .215
1202.2 Piping System Requirements . . . .215
1202.3 Applications . . . . . . . . . . . . . . . . .215
1203.0 Inspection . . . . . . . . . . . . . . . . . . .215
1203.1 Inspection Notification . . . . . . . . .215
1203.2 Excavation . . . . . . . . . . . . . . . . . .215
1203.3 Type of Inspections . . . . . . . . . . .215
1203.4 Inspection Waived . . . . . . . . . . . .216
1204.0 Certificate of Inspection . . . . . . . .216
1204.1 Issuance . . . . . . . . . . . . . . . . . . . .216
1204.2 Gas Supplier . . . . . . . . . . . . . . . . .216
1204.3 Unlawful . . . . . . . . . . . . . . . . . . . .216
1205.0 Authority to Render Gas Service . . . . . . . . . . . . . . . . . . . . .216
1205.1 Authorized Personnel . . . . . . . . . .216
1205.2 Outlets . . . . . . . . . . . . . . . . . . . . .216
1206.0 Authority to Disconnect . . . . . . . .216
1206.1 Disconnection . . . . . . . . . . . . . . . .216
1206.2 Notice . . . . . . . . . . . . . . . . . . . . . .216
1206.3 Capped Outlets . . . . . . . . . . . . . . .216
1207.0 Temporary Use of Gas . . . . . . . . .216
1207.1 General . . . . . . . . . . . . . . . . . . . . .216
1208.0 Gas Piping System Design, Materials, and Components . . . . .216
1208.1 Installation of Piping System . . . .216
1208.2 Interconnections Supplying Separate Users . . . . . . . . . . . . . . .216
1208.3 Sizing of Gas Piping Systems . . .216
Table 1208.3.1 Approximate Gas Input for Typical Appliances . . . . . . . . . . . .217
1208.4 Maximum Operating Pressure in Buildings . . . . . . . . . . . . . . . . . .217
1208.5 Acceptable Piping Materials and Joining Methods . . . . . . . . . .217
Table 1208.5.8.2 Specifications for Threading Metallic Pipe . . . . . . . . . . . . . . . . .219
1208.6 Gas Meters . . . . . . . . . . . . . . . . . .220
1208.7 Gas Pressure Regulators . . . . . . .221
1208.8 Overpressure Protection Required . . . . . . . . . . . . . . . . . . . .221
1208.9 Overpressure Protection Devices . . . . . . . . . . . . . . . . . . . . .221
1208.10 Pressure Limitation
Requirements . . . . . . . . . . . . . . . .222
1208.11 Backpressure Protection . . . . . . .222
1208.12 Low-Pressure Protection . . . . . . .222
1208.13 Shutoff Valves . . . . . . . . . . . . . . .222
1208.14 Expansion and Flexibility . . . . . . .222
1208.15 Pressure Regulator and Pressure Control Venting . . . . . . .222
Table 1208.13 Manual Gas Valve Standards . . . .223
1209.0 Excess Flow Valve . . . . . . . . . . . .223
1209.1 General . . . . . . . . . . . . . . . . . . . . .223
1210.0 Gas Piping Installation . . . . . . . . .223
1210.1 Piping Underground . . . . . . . . . . .223
1210.2 CSST Piping Systems . . . . . . . . .225
1210.3 Installation of Aboveground Piping . . . . . . . . . . . . . . . . . . . . . .225
Table 1210.3.5.1 Support of Piping . . . . . . . . . . . . .225
1210.4 Concealed Piping in Buildings . . .225
1210.5 Piping in Vertical Chases . . . . . . .226
1210.6 Gas Pipe Turns . . . . . . . . . . . . . .226
1210.7 Drips and Sediment Traps . . . . . .227
1210.8 Outlets . . . . . . . . . . . . . . . . . . . . .227
1210.9 Manual Gas Shutoff Valves . . . . .227
1210.10 Prohibited Devices . . . . . . . . . . . .227
1210.11 Systems Containing Gas-Air Mixtures Outside the
Flammable Range . . . . . . . . . . . .227
1210.12 Systems Containing Flammable Gas-Air Mixtures . . . . . . . . . . . . . .227
1211.0 Electrical Bonding and Grounding . . . . . . . . . . . . . . . . . . .229
1211.1 Pipe and Tubing Other than CSST . . . . . . . . . . . . . . . . . . . . . .229
1211.2 Bonding of CSST Gas Piping . . . .229
1211.3 Arc-Resistant Jacketed CSST . . .229
1211.4 Prohibited Use . . . . . . . . . . . . . . .229
1211.5 Lightning Protection System . . . . .229
1211.6 Electrical Circuits . . . . . . . . . . . . .229
1211.7 Electrical Connections . . . . . . . . .229
TABLE OF CONTENTS
1211.8 Earthquake-Actuated Gas Shutoff Valves . . . . . . . . . . . . . . . .229
1212.0 Appliance and Equipment Connections to Building Piping . . .229
1212.1 Connecting Appliances and Equipment . . . . . . . . . . . . . . . . . .229
1212.2 Suspended Low-Intensity Infrared Tube Heaters . . . . . . . . .230
1212.3 Use of Nonmetallic Gas
Hose Connectors . . . . . . . . . . . . .230
1212.4 Injection (Bunsen) Burners . . . . . .230
1212.5 Connection of Portable
and Mobile Industrial
Gas Appliances . . . . . . . . . . . . . .230
1212.6 Appliance Shutoff Valves and Connections . . . . . . . . . . . . . .230
1212.7 Quick-Disconnect Devices . . . . . .230
1212.8 Gas Convenience Outlets . . . . . .231
1212.9 Sediment Trap . . . . . . . . . . . . . . .231
1212.10 Installation of Piping . . . . . . . . . . .231
1212.11 Liquefied Petroleum Gas Facilities and Piping . . . . . . . . . . .231
1213.0 Pressure Testing, Inspection, and Purging . . . . . . . . . . . . . . . . .231
1213.1 Piping Installations . . . . . . . . . . . .231
1213.2 Test Preparation . . . . . . . . . . . . . .231
1213.3 Test Pressure . . . . . . . . . . . . . . . .232
1213.4 Detection of Leaks and Defects . .232
1213.5 Piping System Leak Test . . . . . . .232
1213.6 Purging Requirements . . . . . . . . .232
Table 1213.6.1 Size and Length of Piping . . . . . .232
1214.0 Required Gas Supply . . . . . . . . . .233
1214.1 General . . . . . . . . . . . . . . . . . . . . .233
1214.2 Volume . . . . . . . . . . . . . . . . . . . . .233
1214.3 Gas Appliances . . . . . . . . . . . . . .233
1214.4 Size of Piping Outlets . . . . . . . . . .233
1215.0 Required Gas Piping Size . . . . . .234
1215.1 Pipe Sizing Methods . . . . . . . . . . .234
1215.2 Sizing of Gas Piping Systems . . .234
1215.3 Sizing Equations . . . . . . . . . . . . . .234
Table 1215.3 Cr and Y for Natural Gas
and Undiluted Propane at Standard Conditions . . . . . . . . . . .234
1215.4 Sizing of Piping Sections . . . . . . .234
1215.5 Engineering Methods . . . . . . . . . .235
1215.6 Variable Gas Pressure . . . . . . . . .235
Table 1215.2(1) Schedule 40 Metallic Pipe . . . . . .237
Table 1215.2(2) Schedule 40 Metallic Pipe . . . . . .238
Table 1215.2(3) Schedule 40 Metallic Pipe . . . . . .239
Table 1215.2(4) Schedule 40 Metallic Pipe . . . . . .240
Table 1215.2(5) Schedule 40 Metallic Pipe . . . . . .241
Table 1215.2(6) Schedule 40 Metallic Pipe . . . . . .242
Table 1215.2(7) Semi-Rigid Copper Tubing . . . . . .243
Table 1215.2(8) Semi-Rigid Copper Tubing . . . . . .244
Table 1215.2(9) Semi-Rigid Copper Tubing . . . . . .245
Table 1215.2(10) Semi-Rigid Copper Tubing . . . . . .246
Table 1215.2(11) Semi-Rigid Copper Tubing . . . . . .247
Table 1215.2(12) Semi-Rigid Copper Tubing . . . . . .248
Table 1215.2(13) Semi-Rigid Copper Tubing . . . . . .249
Table 1215.2(14) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .250
Table 1215.2(15) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .251
Table 1215.2(16) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .252
Table 1215.2(17) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .253
Table 1215.2(18) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .254
Table 1215.2(19) Polyethylene Plastic Pipe . . . . . . .255
Table 1215.2(20) Polyethylene Plastic Pipe . . . . . . .256
Table 1215.2(21) Polyethylene Plastic Pipe . . . . . . .257
Table 1215.2(22) Polyethylene Plastic Tubing . . . . .258
Table 1215.2(23) Polyethylene Plastic Tubing . . . . .258
Table 1215.2(24) Schedule 40 Metallic Pipe . . . . . .259
Table 1215.2(25) Schedule 40 Metallic Pipe . . . . . .260
Table 1215.2(26) Schedule 40 Metallic Pipe . . . . . .261
Table 1215.2(27) Schedule 40 Metallic Pipe . . . . . .262
Table 1215.2(28) Semi-Rigid Copper Tubing . . . . . .263
Table 1215.2(29) Semi-Rigid Copper Tubing . . . . . .264
Table 1215.2(30) Semi-Rigid Copper Tubing . . . . . .265
Table 1215.2(31) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .266
Table 1215.2(32) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .267
Table 1215.2(33) Corrugated Stainless Steel Tubing (CSST) . . . . . . . . . . . . . . .268
Table 1215.2(34) Polyethylene Plastic Pipe . . . . . . .269
Table 1215.2(35) Polyethylene Plastic Pipe . . . . . . .270
Table 1215.2(36) Polyethylene Plastic Tubing . . . . .271
CHAPTER 13 HEALTH CARE FACILITIES AND
MEDICAL GAS AND MEDICAL
VACUUM SYSTEMS . . . . . . . . . .273
PART I General Requirements . . . . . . . .275
1301.0 General Requirements . . . . . . . . .275
1301.1 Applicability . . . . . . . . . . . . . . . . . .275
1301.2 Where Not Applicable . . . . . . . . . .275
1301.3 Conflict of Requirements . . . . . . .275
1301.4 Where Required . . . . . . . . . . . . . .275
TABLE OF CONTENTS
1301.5 Existing Systems . . . . . . . . . . . . .275
1302.0 Design Requirements . . . . . . . . . .275
1302.1 Risk Categories . . . . . . . . . . . . . .275
1302.2 Patient Care Spaces . . . . . . . . . .275
1302.3 Anesthesia . . . . . . . . . . . . . . . . . .275
1302.4 Wet Procedure Locations . . . . . . .275
1303.0 Health Care Facilities . . . . . . . . . .275
1303.1 Drinking Fountain Control Valves . . . . . . . . . . . . . . . . . . . . . .275
1303.2 Psychiatric Patient Rooms . . . . . .275
1303.3 Locations for Ice Storage . . . . . . .276
1303.4 Sterilizers and Bedpan Steamers . . . . . . . . . . . . . . . . . . .276
1303.5 Aspirators . . . . . . . . . . . . . . . . . . .276
1303.6 Drains . . . . . . . . . . . . . . . . . . . . . .276
1303.7 Clinical Sinks . . . . . . . . . . . . . . . .276
1303.8 Water Supply for Hospitals . . . . . .276
1303.9 Work Performed in Occupied Healthcare Facilities . . . . . . . . . . .276
1304.0 Medical Gas and Medical Vacuum Piping Systems . . . . . . .276
1304.1 General . . . . . . . . . . . . . . . . . . . . .276
1304.2 Certification of Systems . . . . . . . .276
1304.3 Construction Documents . . . . . . .276
1304.4 Extent of Work . . . . . . . . . . . . . . .276
1304.5 Record . . . . . . . . . . . . . . . . . . . . .276
1305.0 System Performance . . . . . . . . . .276
1305.1 Required Operating Pressures . . .276
Table 1305.1 Standard Designation Colors and Operating Pressures for Gas and Vacuum Systems . . . . . .277
1305.2 Minimum Flow Rates . . . . . . . . . .277
1305.3 Minimum Station Outlets
and Inlets . . . . . . . . . . . . . . . . . . .277
1306.0 System Certification . . . . . . . . . . .277
1306.1 Certification . . . . . . . . . . . . . . . . . .277
1306.2 Certification Tests . . . . . . . . . . . . .277
1306.3 Report Items . . . . . . . . . . . . . . . . .277
1306.4 Components . . . . . . . . . . . . . . . . .277
Table 1305.2 Minimum Flow Rates . . . . . . . . . .277
Table 1305.3 Minimum Outlets and Inlets
Per Station . . . . . . . . . . . . . . . . . .278
PART II Category 1 Piped Gas and Vacuum Systems . . . . . . . . . . . .278
1307.0 Central Supply Systems . . . . . . . .278
1307.1 Terms . . . . . . . . . . . . . . . . . . . . . .278
1307.2 Nature of Hazards of Gas
and Vacuum Systems . . . . . . . . .278
1307.3 Permitted Locations for
Medical Gases . . . . . . . . . . . . . . .278
1307.4 Materials . . . . . . . . . . . . . . . . . . . .278
1308.0 Pressure-Regulating Equipment . .278
1308.1 Where Required . . . . . . . . . . . . . .278
1308.2 Pressure Relief Valves . . . . . . . . .278
1308.3 Pressure-Relief Valve
Requirements . . . . . . . . . . . . . . . .279
1309.0 Oxygen Concentrator Supply Units . . . . . . . . . . . . . . . . .279
1309.1 Oxygen Requirements . . . . . . . . .279
1309.2 Particulate Size . . . . . . . . . . . . . . .279
1309.3 Suitability . . . . . . . . . . . . . . . . . . .279
1309.4 Compatible Materials . . . . . . . . . .279
1309.5 Oxygen Concentrator Components . . . . . . . . . . . . . . . . .279
1309.6 Supply Air Quality . . . . . . . . . . . . .279
1309.7 Electrical Components . . . . . . . . .279
1309.8 Vent Valve . . . . . . . . . . . . . . . . . .279
1309.9 Valved Sample Port . . . . . . . . . . .279
1309.10 Suitable Filter . . . . . . . . . . . . . . . .279
1309.11 Check Valve . . . . . . . . . . . . . . . . .279
1309.12 Outlet Valve . . . . . . . . . . . . . . . . .279
1309.13 Oxygen Concentration Monitor . . .280
1310.0 Category 1 Medical Air Central Supply Systems . . . . . . . .280
1310.1 Quality of Medical Air . . . . . . . . . .280
1310.2 Uses of Medical Air . . . . . . . . . . .280
1310.3 Medical Air Compressors . . . . . . .280
1310.4 Medical Air Receivers . . . . . . . . . .280
1310.5 Valves . . . . . . . . . . . . . . . . . . . . . .280
1311.0 Compressor Intake . . . . . . . . . . . .280
1311.1 Air Sources . . . . . . . . . . . . . . . . . .280
1311.2 Medical Air Compressor Source . . . . . . . . . . . . . . . . . . . . .281
1311.3 Air Intakes . . . . . . . . . . . . . . . . . . .281
1311.4 Location . . . . . . . . . . . . . . . . . . . .281
1311.5 Separate Compressors . . . . . . . . .281
1311.6 Screening . . . . . . . . . . . . . . . . . . .281
1312.0 Medical Surgical Vacuum Central Supply Systems . . . . . . . .281
1312.1 General . . . . . . . . . . . . . . . . . . . . .281
1312.2 Medical-Surgical Vacuum Sources . . . . . . . . . . . . . . . . . . . .281
1312.3 Vacuum Receivers . . . . . . . . . . . .281
1312.4 Vacuum Filtration . . . . . . . . . . . . .281
1312.5 Piping Arrangement and Redundancies . . . . . . . . . . . . . . . .282
1312.6 Piping Serviceability . . . . . . . . . . .282
1312.7 Shutoff Valve . . . . . . . . . . . . . . . .282
1313.0 Medical-Surgical Vacuum Exhaust . . . . . . . . . . . . . . . . . . . . .282
TABLE OF CONTENTS
1313.1 Vacuum Source Exhausts . . . . . .282
1313.2 Location . . . . . . . . . . . . . . . . . . . .282
1313.3 Screening . . . . . . . . . . . . . . . . . . .282
1313.4 Dips and Loops . . . . . . . . . . . . . .282
1313.5 Multiple Pumps . . . . . . . . . . . . . . .282
1314.0 Valves . . . . . . . . . . . . . . . . . . . . . .282
1314.1 Gas and Vacuum Shutoff
Valves . . . . . . . . . . . . . . . . . . . . . .282
1314.2 Security . . . . . . . . . . . . . . . . . . . . .282
1314.3 Labeled . . . . . . . . . . . . . . . . . . . . .282
1314.4 Accessibility . . . . . . . . . . . . . . . . .282
1314.5 Valve Types . . . . . . . . . . . . . . . . .282
Table 1314.5(1) Positive Pressure Gases . . . . . . .283
Table 1314.5(2) Vacuum and WAGD . . . . . . . . . . .283
1314.6 Source Valves . . . . . . . . . . . . . . .283
1314.7 Main Line Valve . . . . . . . . . . . . . .283
1314.8 Riser Valves . . . . . . . . . . . . . . . . .283
1314.9 Service Valves . . . . . . . . . . . . . . .283
1314.10 Zone Valves . . . . . . . . . . . . . . . . .283
1314.11 In-Line Shutoff Valves . . . . . . . . .284
1314.12 Valves for Future Connections . . .284
1315.0 Station Outlets and Inlets . . . . . . .284
1315.1 General . . . . . . . . . . . . . . . . . . . . .284
1315.2 Required Valves . . . . . . . . . . . . . .284
1315.3 Secondary Valve . . . . . . . . . . . . .284
1315.4 Identification . . . . . . . . . . . . . . . . .284
1315.5 Threaded Outlets/Fittings . . . . . . .284
1315.6 Gas-Specific Station Outlet/Inlet . . . . . . . . . . . . . . . . . .284
1315.7 Common Parts . . . . . . . . . . . . . . .284
1315.8 Marking of Components . . . . . . . .284
1315.9 Components Not Specific to a Vacuum . . . . . . . . . . . . . . . . .284
1315.10 Factory-Installed Copper Inlet Tubes . . . . . . . . . . . . . . . . . .284
1315.11 Factory-Installed Copper Outlet Tubes . . . . . . . . . . . . . . . . .284
1315.12 Protection from Damage . . . . . . .284
1315.13 Multiple Wall Outlets/Inlets . . . . . .284
1315.14 Nonstandard Operation Pressures . . . . . . . . . . . . . . . . . . .284
1315.15 Post Installation . . . . . . . . . . . . . .284
1316.0 Pressure and Vacuum
Indicator Locations . . . . . . . . . . . .284
1316.1 Isolation . . . . . . . . . . . . . . . . . . . .284
1316.2 Pressure and Vacuum
Indicator Locations . . . . . . . . . . . .284
1317.0 Warning Systems . . . . . . . . . . . . .285
1317.1 Category 1 . . . . . . . . . . . . . . . . . .285
1318.0 Piping Materials for Field-Installed Positive Pressure
Medical Gas Systems . . . . . . . . . .285
1318.1 General . . . . . . . . . . . . . . . . . . . . .285
1318.2 Cleaning . . . . . . . . . . . . . . . . . . . .285
1318.3 Delivery . . . . . . . . . . . . . . . . . . . . .285
1318.4 Tubes for Medical Gas Systems . .285
1318.5 Manufacturer Markings . . . . . . . . .285
1318.6 Documentation . . . . . . . . . . . . . . .285
1319.0 Piping Materials for Field-Installed Medical-Surgical Vacuum Systems . . . . . . . . . . . . .285
1319.1 Tubes for Medical Vacuum
Systems . . . . . . . . . . . . . . . . . . . .285
1320.0 Joints and Connections . . . . . . . .286
1320.1 General . . . . . . . . . . . . . . . . . . . . .286
1320.2 Changes in Direction . . . . . . . . . .286
1321.0 Brazed Joints . . . . . . . . . . . . . . . .286
1321.1 Brazed Joints and Fittings . . . . . .286
1321.2 Tube Joints . . . . . . . . . . . . . . . . . .286
1321.3 Filler Metals . . . . . . . . . . . . . . . . .286
1321.4 Copper-to-Copper Joints . . . . . . .286
1321.5 Accessible . . . . . . . . . . . . . . . . . .286
1321.6 Purging . . . . . . . . . . . . . . . . . . . . .286
1321.7 Tube Ends . . . . . . . . . . . . . . . . . .286
1321.8 Cleaning Procedures . . . . . . . . . .286
1321.9 Brazing Dissimilar Metals . . . . . . .287
1321.10 Nitrogen Purge . . . . . . . . . . . . . . .287
1321.11 Assembling and Heating Brazed Joints . . . . . . . . . . . . . . . .287
1321.12 Inspection of Brazed Joints . . . . .287
1322.0 Welded Joints . . . . . . . . . . . . . . . .288
1322.1 Welded Joints Procedure . . . . . . .288
1322.2 Welding for Stainless Tube . . . . .288
1322.3 Memory Metal Fittings . . . . . . . . .288
1322.4 Axially Swaged Fittings . . . . . . . .288
1322.5 Threaded Fittings . . . . . . . . . . . . .288
1322.6 Other Types of Fittings . . . . . . . . .288
1322.7 Prohibited Joints . . . . . . . . . . . . . .288
1323.0 Installation of Piping and Equipment . . . . . . . . . . . . . . . . . .289
1323.1 Required Pipe Sizing . . . . . . . . . .289
Table 1323.1.5(1) System Sizing – Flow Requirements for Station Outlets and Inlets . . . . . . . . . . . . .289
Table 1323.1.5(2) Maximum Permitted Pressure Loss In Medical Gas and
Medical Vacuum Systems . . . . . . .289
1323.2 Pipe Protection . . . . . . . . . . . . . . .289
Table 1323.1.4(1) Pressure Loss for Medical Air . . . . .290
TABLE OF CONTENTS
Table 1323.1.4(2) Pressure Loss for Nitrogen . . . . . . .290
Table 1323.1.4(3) Pressure Loss for Nitrous Oxide and Carbon Dioxide . . . . . . .291
Table 1323.1.4(4) Pressure Loss for Oxygen . . . . . . .291
Table 1323.1.4(5) Pressure Loss for Vacuum . . . . . . .292
Table 1323.1.4(6) Pressure Loss for Vacuum (Category 3) . . . . . . . . . . . . . . . . . . .292
1323.3 Location of Piping . . . . . . . . . . . . .293
1323.4 Pipe Support . . . . . . . . . . . . . . . . .293
Table 1323.4.4 Maximum Pipe Support Spacing . . . . . . . . . . . . . . . . . . . . . .293
1323.5 Frost Protection . . . . . . . . . . . . . .293
1323.6 Connectors . . . . . . . . . . . . . . . . . .294
1323.7 Prohibited System Interconnections . . . . . . . . . . . . . .294
1323.8 Manufacturer’s Instructions . . . . .294
1323.9 Changes in System Use . . . . . . . .294
1323.10 Qualifications of Installers . . . . . .294
1323.11 Qualification of Brazing Procedures and Brazing . . . . . . . .295
1323.12 Breaching or Penetrating Medical Gas Piping . . . . . . . . . . .295
1323.13 Labeling, Identification and Operating Pressure . . . . . . . . . . .295
1323.14 Identification of Shutoff Valves . . .295
1323.15 Identification . . . . . . . . . . . . . . . . .296
1324.0 Performance Criteria and Testing Category 1 (Gases, Medical Surgical Vacuum) . . . . . .296
1324.1 Where Required . . . . . . . . . . . . . .296
1324.2 Breached Systems . . . . . . . . . . . .296
1324.3 Test Gas . . . . . . . . . . . . . . . . . . . .296
1324.4 Initial Piping Blowdown . . . . . . . . .296
1324.5 Initial Pressure Tests– Medical
Gas and Vacuum Systems . . . . . .296
Table 1324.5.11 Gas Concentrations . . . . . . . . . . .299
PART III Category 2 Piped Gas and Vacuum Systems . . . . . . . . . . . .299
1325.0 Category 2 Piped Gas and Vacuum Systems . . . . . . . . . . . . .299
1325.1 General . . . . . . . . . . . . . . . . . . . . .299
1325.2 Nature of Hazards of Gas
and Vacuum Systems . . . . . . . . .299
1325.3 Central Supply Systems . . . . . . . .299
1325.4 Category 2 Medical Air Supply Systems . . . . . . . . . . . . . .299
1325.5 Oxygen Concentrators . . . . . . . . .299
1325.6 Category 2 Medical-Surgical Vacuum . . . . . . . . . . . . . . . . . . . .299
1325.7 Valves . . . . . . . . . . . . . . . . . . . . . .299
1325.8 Station Outlets and Inlets . . . . . . .299
1325.9 Pressure and Vacuum
Indicators . . . . . . . . . . . . . . . . . . .299
1325.10 Warning Systems . . . . . . . . . . . . .299
1325.11 Category 2 Distribution . . . . . . . . .299
1325.12 Labeling and Identification . . . . . .299
1325.13 Performance Criteria and Testing — Gas, Medical–Surgical Vacuum, and WAGD . . . . . . . . . . .299
PART IV Category 3 Piped Gas and Vacuum Systems . . . . . . . . . . . .300
1326.0 Category 3 Piped Gas and Vacuum Systems . . . . . . . . . . . . .300
1326.1 General . . . . . . . . . . . . . . . . . . . . .300
1326.2 Nature of Hazards of Gas and Vacuum Systems . . . . . . . . .300
1326.3 Medical Air Supply Systems . . . . .300
1326.4 Medical–Surgical Vacuum Systems . . . . . . . . . . . . . . . . . . . .300
1326.5 Valves . . . . . . . . . . . . . . . . . . . . . .300
1326.6 Station Outlets and Inlets . . . . . . .300
1326.7 Pressure and Vacuum
Indicators . . . . . . . . . . . . . . . . . . .300
1326.8 Warning Systems . . . . . . . . . . . . .300
1326.9 Distribution . . . . . . . . . . . . . . . . . .300
1326.10 Labeling and Identification . . . . . .300
PART V Dental Gas and Vacuum Systems . . . . . . . . . . . . . . . . . . . .300
1327.0 Dental Gas and Vacuum Systems . . . . . . . . . . . . . . . . . . . .300
1327.1 General . . . . . . . . . . . . . . . . . . . . .300
1327.2 Emergency Shutoff Valves (Oxygen and Nitrous Oxide) . . . . .300
1327.3 Warning Systems (Oxygen and Nitrous Oxide) . . . . . . . . . . . .300
1327.4 Initial Pressure Test . . . . . . . . . . .301
1327.5 Maximum Copper Tube Support Spacing . . . . . . . . . . . . . .301
Table 1327.5 Maximum Copper Tube Support Spacing . . . . . . . . . . . . . .301
1327.6 Maximum Plastic Pipe Support Spacing . . . . . . . . . . . . . .301
Table 1327.6 Maximum Plastic Pipe Support Spacing . . . . . . . . . . . . . .301
1327.7 Standing Pressure Tests for Oxygen and Nitrous Oxide Piping . . . . . . . . . . . . . . . . . . . . . .301
1327.8 Verifier Operational Pressure Test . . . . . . . . . . . . . . . .302
CHAPTER 14 FIRESTOP PROTECTION . . . . . .303
1401.0 General . . . . . . . . . . . . . . . . . . . . .305
1401.1 Applicability . . . . . . . . . . . . . . . . . .305
TABLE OF CONTENTS
1402.0 Construction Documents . . . . . . .305
1402.1 Penetrations . . . . . . . . . . . . . . . . .305
1403.0 Installation . . . . . . . . . . . . . . . . . .305
1403.1 Materials . . . . . . . . . . . . . . . . . . . .305
1404.0 Combustible Piping Installations . . . . . . . . . . . . . . . . . .305
1404.1 General Requirements . . . . . . . . .305
1404.2 Fire-Resistance Rating . . . . . . . . .305
1404.3 Firestop Systems . . . . . . . . . . . . .305
1404.4 Connections . . . . . . . . . . . . . . . . .305
1404.5 Insulation and Coverings . . . . . . .305
1404.6 Sleeves . . . . . . . . . . . . . . . . . . . . .305
1405.0 Noncombustible Piping Installations . . . . . . . . . . . . . . . . . .305
1405.1 General Requirements . . . . . . . . .305
1405.2 Fire-Resistance Rating . . . . . . . . .305
1405.3 Firestop Systems . . . . . . . . . . . . .305
1405.4 Connections . . . . . . . . . . . . . . . . .305
1405.5 Unshielded Couplings . . . . . . . . . .306
1405.6 Sleeves . . . . . . . . . . . . . . . . . . . . .306
1405.7 Insulation and Coverings . . . . . . .306
1406.0 Required Inspection . . . . . . . . . . .306
1406.1 General . . . . . . . . . . . . . . . . . . . . .306
1406.2 Examination . . . . . . . . . . . . . . . . .306
1406.3 Penetrations . . . . . . . . . . . . . . . . .306
1406.4 Field Installations . . . . . . . . . . . . .306
CHAPTER 15 ALTERNATE WATER SOURCES
FOR NONPOTABLE
APPLICATIONS . . . . . . . . . . . . . .307
1501.0 General . . . . . . . . . . . . . . . . . . . . .309
1501.1 Applicability . . . . . . . . . . . . . . . . . .309
1501.2 System Design . . . . . . . . . . . . . . .309
1501.3 Permit . . . . . . . . . . . . . . . . . . . . . .309
1501.4 Component Identification . . . . . . .309
1501.5 Maintenance and Inspection . . . .309
1501.6 Operation and Maintenance Manual . . . . . . . . . . . . . . . . . . . . .309
1501.7 Minimum Water Quality Requirements . . . . . . . . . . . . . . . .309
Table 1501.5 Recommended Minimum Alternate Water Source Testing, Inspection, and Maintenance Frequency . . . . . . . . . . . . . . . . . . .310
1501.8 Material Compatibility . . . . . . . . . .310
1501.9 Signage . . . . . . . . . . . . . . . . . . . .310
1501.10 System Controls . . . . . . . . . . . . . .310
1502.0 Inspection and Testing . . . . . . . . .310
1502.1 General . . . . . . . . . . . . . . . . . . . . .310
1502.2 Supply System Inspection and Test . . . . . . . . . . . . . . . . . . . .310
1502.3 Cross-Connection
Inspection and Testing . . . . . . . . .310
1502.4 Separation Requirements . . . . . . .311
1502.5 Abandonment . . . . . . . . . . . . . . . .311
1502.6 Sizing . . . . . . . . . . . . . . . . . . . . . .312
1503.0 Gray Water Systems . . . . . . . . . .312
1503.1 General . . . . . . . . . . . . . . . . . . . . .312
1503.2 System Requirements . . . . . . . . .313
1503.3 Connections to Potable and
Reclaimed (Recycled) Water Systems . . . . . . . . . . . . . . . . . . . . .313
1503.4 Location . . . . . . . . . . . . . . . . . . . .313
1503.5 Plot Plan Submission . . . . . . . . . .313
1503.6 Prohibited Location . . . . . . . . . . . .313
Table 1503.4 Location of Gray Water System . . .314
1503.7 Drawings and Specifications . . . .314
1503.8 Procedure for Estimating Gray Water Discharge . . . . . . . . .314
1503.9 Gray Water System Components . . . . . . . . . . . . . . . . .315
1504.0 Subsurface Irrigation System Zones . . . . . . . . . . . . . . . .316
1504.1 General . . . . . . . . . . . . . . . . . . . . .316
1504.2 Required Area of Subsurface Irrigation Fields, Subsoil Irrigation Fields, and Mulch Basins . . . . . . . . . . . . . . . .316
1504.3 Determination of Maximum
Absorption Capacity . . . . . . . . . . .316
Table 1504.2 Design of Six Typical Soils . . . . . .316
1504.4 Groundwater Level . . . . . . . . . . . .316
1504.5 Irrigation, Disposal Field and Mulch Basin Construction . . . . . .316
Table 1504.5.3 Subsoil Irrigation Field Construction . . . . . . . . . . . . . . . . .318
Table 1504.5.5 Subsurface Irrigation Design Criteria for Six Typical Soils . . . . .318
1504.6 Reserved . . . . . . . . . . . . . . . . . . .318
1504.7 Reserved . . . . . . . . . . . . . . . . . . .318
1504.8 Gray Water System Color and Marking Information . . . . . . . .318
1504.9 Other Collection and
Distribution Systems . . . . . . . . . . .318
1504.10 Testing . . . . . . . . . . . . . . . . . . . . .318
1504.11 Maintenance . . . . . . . . . . . . . . . . .318
1505.0 Recycled Water Supply Systems in Buildings . . . . . . . . . .318
1505.1 General . . . . . . . . . . . . . . . . . . . . .318
1505.2 Permit . . . . . . . . . . . . . . . . . . . . . .319
1505.3 System Changes . . . . . . . . . . . . .319
TABLE OF CONTENTS
1505.4 Connections to Potable or Recycled Water Supply Systems . . . . . . . . . . . . . . . . . . . .319
1505.5 Water Pressure . . . . . . . . . . . . . . .319
1505.6 Initial Cross-Connection Test . . . .319
1505.7 Recycled Water Supply System Materials . . . . . . . . . . . . .319
1505.8 Recycled Water Supply System Color and Marking Information . . . . . . . . . . . . . . . . . .319
1505.9 Valves . . . . . . . . . . . . . . . . . . . . . .319
1505.10 Hose Bibbs . . . . . . . . . . . . . . . . . .320
1505.11 Required Appurtenances . . . . . . .320
1505.12 Pipe Separation in Trenches . . . .320
1505.13 Signage . . . . . . . . . . . . . . . . . . . .320
1505.14 Inspection and Testing . . . . . . . . .320
1505.15 Minimum Water Quality Requirements for Reclaimed (Recycled) Water . . . . . . . . . . . . .322
1505.16 Maintenance and Inspection . . . .322
Table 1505.16 Minimum Reclaimed (Recycled) Water Source Testing, Inspection, and Maintenance Frequency . . . . . . .322
1506.0 On-Site Treated Nonpotable Gray Water Systems . . . . . . . . . .322
1506.1 General . . . . . . . . . . . . . . . . . . . . .322
1506.2 Plumbing Plan Submission . . . . . .322
1506.3 System Changes . . . . . . . . . . . . .322
1506.4 Connections to Potable or Recycled Water Supply Systems . . . . . . . . . . . . . . . . . . . .322
1506.5 Water Pressure . . . . . . . . . . . . . . .322
1506.6 Initial Cross-Connection Test . . . .323
1506.7 On-Site Treated Nonpotable Gray Water System Materials . . .323
1506.8 On-Site Treated Nonpotable Gray Water Devices and Systems . . . . . . . . . . . . . . . . . . . .323
1506.9 On-Site Treated Nonpotable Gray Water System Color and Marking Information . . . . . . . . . . .323
1506.10 Design and Installation . . . . . . . . .323
1506.11 Valves . . . . . . . . . . . . . . . . . . . . . .323
1506.12 Signs . . . . . . . . . . . . . . . . . . . . . . .323
1506.13 Inspection and Testing . . . . . . . . .323
CHAPTER 16 NONPOTABLE RAINWATER
CATCHMENT SYSTEMS . . . . . . .325
1601.0 General . . . . . . . . . . . . . . . . . . . . .327
1601.1 Applicability . . . . . . . . . . . . . . . . . .327
1601.2 System Design . . . . . . . . . . . . . . .327
1601.3 Permit . . . . . . . . . . . . . . . . . . . . . .327
1601.4 Component Identification . . . . . . .327
1601.5 Maintenance and Inspection . . . .327
Table 1601.5 Minimum Alternate Water Source Testing, Inspection, and Maintenance Frequency . . . .327
1601.6 Operation and Maintenance Manual . . . . . . . . . . . . . . . . . . . . .328
1601.7 Minimum Water Quality Requirements . . . . . . . . . . . . . . . .328
1601.8 Material Compatibility . . . . . . . . . .328
1601.9 System Controls . . . . . . . . . . . . . .328
1601.10 Separation Requirements . . . . . . .328
1601.11 Abandonment . . . . . . . . . . . . . . . .328
1601.12 Sizing . . . . . . . . . . . . . . . . . . . . . .328
1602.0 Nonpotable Rainwater Catchment Systems . . . . . . . . . . .328
1602.1 General . . . . . . . . . . . . . . . . . . . . .328
1602.2 Plumbing Plan Submission . . . . . .328
1602.3 System Changes . . . . . . . . . . . . .328
1602.4 Connections to Potable or Reclaimed (Recycled) Water Systems . . . . . . . . . . . . . . .328
1602.5 Initial Cross-Connection Test . . . .328
1602.6 Sizing . . . . . . . . . . . . . . . . . . . . . .328
1602.7 Rainwater Catchment System Materials . . . . . . . . . . . . . . . . . . . .329
1602.8 Rainwater Catchment System Color and Marking Information . . .329
1602.9 Deactivation and Drainage for Cross-Connection Test . . . . . . . . .329
1603.0 Design and Installation . . . . . . . . .329
1603.1 Rainwater Catchment Systems . . .329
1603.2 Outside Hose Bibbs . . . . . . . . . . .329
1603.3 Rainwater Catchment
Collection Surfaces . . . . . . . . . . . .329
1603.4 Minimum Water Quality . . . . . . . .329
1603.5 Rainwater Storage Tanks . . . . . . .329
1603.6 Location . . . . . . . . . . . . . . . . . . . .329
1603.7 Above Grade . . . . . . . . . . . . . . . .329
1603.8 Below Grade . . . . . . . . . . . . . . . . .329
Table 1603.4 Minimum Water Quality . . . . . . . .330
1603.9 Drainage and Overflow . . . . . . . . .330
1603.10 Opening and Access Protection . . .330
1603.11 Marking . . . . . . . . . . . . . . . . . . . . .330
1603.12 Storage Tank Venting . . . . . . . . . .330
1603.13 Pumps . . . . . . . . . . . . . . . . . . . . .330
1603.14 Roof Drains . . . . . . . . . . . . . . . . . .331
1603.15 Water Quality Devices and Equipment . . . . . . . . . . . . . . . . . .331
1603.16 Freeze Protection . . . . . . . . . . . . .331
1603.17 Debris Removal . . . . . . . . . . . . . .331
1603.18 Required Filters . . . . . . . . . . . . . .331
1603.19 Roof Gutters . . . . . . . . . . . . . . . . .331
1603.20 Rainwater Diversion Valves . . . . .331
1604.0 Signs . . . . . . . . . . . . . . . . . . . . . . .331
1604.1 General . . . . . . . . . . . . . . . . . . . . .331
1604.2 Commercial, Industrial,
Institutional and Residential
Restroom Signs . . . . . . . . . . . . . .331
1604.3 Equipment Room Signs . . . . . . . .331
1605.0 Inspection and Testing . . . . . . . . .331
1605.1 General . . . . . . . . . . . . . . . . . . . . .331
1605.2 Supply System Inspection and Test . . . . . . . . . . . . . . . . . . . .331
1605.3 Cross-Connection Inspection and Testing . . . . . . . . . . . . . . . . . .331
CHAPTER 17 REFERENCED STANDARDS . . .333
1701.0 General . . . . . . . . . . . . . . . . . . . . .335
1701.1 Standards . . . . . . . . . . . . . . . . . . .335
Table 1701.1 Referenced Standards . . . . . . . . .335
1701.2 Standards, Publications, Practices, and Guides . . . . . . . . .352
Table 1701.2 Standards, Publications, Practices, and Guides . . . . . . . . .352
APPENDICES TABLE OF CONTENTS . . . . . . . .363
Appendix A Recommended Rules for Sizing the Water Supply System . . . . . . . . . . . . . . . . . . . . .365
Appendix B Explanatory Notes on Combination Waste and Vent
Systems . . . . . . . . . . . . . . . . . . . .381
Appendix C Alternate Plumbing Systems . . . .385
Appendix D Sizing Storm Water Drainage Systems . . . . . . . . . . . . . . . . . . . .395
Appendix E Manufactured/Mobile Home Parks and Recreational
Vehicle Parks . . . . . . . . . . . . . . . .405
Appendix F Firefighter Breathing Air Replenishment Systems . . . . . . . .417
Appendix G Sizing of Venting Systems . . . . . .423
Appendix H Private Sewage Disposal Systems . . . . . . . . . . . . . . . . . . . .435
Appendix I Installation Standards . . . . . . . . . .447
Appendix J Combination of Indoor and Outdoor Combustion and
Ventilation Opening Design . . . . .487
Appendix K Potable Rainwater Catchment Systems . . . . . . . . . . .491
Appendix L Sustainable Practices . . . . . . . . . .497
Appendix M Peak Water Demand Calculator . . . . . . . . . . . . . . . . . . .517
Appendix N Impact Of Water Temperature On The Potential for Scalding and Legionella Growth . . . . . . . . .525
Appendix O Non-Sewered Sanitation Systems . . . . . . . . . . . . . . . . . . . .531
Appendix P Professional Qualifications . . . . . .535
Appendix Q Indoor Horticultural Facilities . . . .539
Appendix R Tiny Houses . . . . . . . . . . . . . . . . .543
Appendix S Onsite Stormwater Treatment Systems . . . . . . . . . . . . . . . . . . . .547
USEFUL TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . .553
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . .563
HISTORY NOTE
APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . .589
CHAPTER 1 - ADMINISTRATION
(Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
| Adopting Agency | BSC | BSC-CG | SFM | HCD 1 | HCD 2 | HCD 1-AC | DSA AC | DSA SS | DSA SS/CC | OSHPD 1 | OSHPD 1R | OSHPD 2 | OSHPD 3 | OSHPD 4 | OSHPD 5 | OSHPD 6 | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopt Entire Chapter | ||||||||||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) | ||||||||||||||||||||||||
| Adopt only those sections that are listed below | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | ||
| Chapter/ |
||||||||||||||||||||||||
| Division I – California Administration | ||||||||||||||||||||||||
| 1.1.1 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.2 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.3 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.4 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.5 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.6 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.7 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.8 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.8.2 | X | |||||||||||||||||||||||
| 1.1.9 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.10 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.11 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.1.12 | X | X | X | X | X | X | X | X | X | X | X | X | X | |||||||||||
| 1.2.0 | X | X | ||||||||||||||||||||||
| 1.3.0 | X | |||||||||||||||||||||||
| 1.4.0 | X | |||||||||||||||||||||||
| 1.5.0 | X | |||||||||||||||||||||||
| 1.6.0 | X | |||||||||||||||||||||||
| 1.7.0 | X | |||||||||||||||||||||||
| 1.8.0 | X | X | X | |||||||||||||||||||||
| 1.9.0 | X | |||||||||||||||||||||||
| 1.9.1 | X | |||||||||||||||||||||||
| 1.9.1.1 | X | |||||||||||||||||||||||
| 1.9.2 | X | |||||||||||||||||||||||
| 1.9.2.1 | X | |||||||||||||||||||||||
| 1.9.2.1.1 | X | |||||||||||||||||||||||
| 1.9.2.2 | X | |||||||||||||||||||||||
| 1.9.2.2.1 | X | |||||||||||||||||||||||
| 1.10.1 | X | X | ||||||||||||||||||||||
| 1.10.2 | X | |||||||||||||||||||||||
| 1.10.3 | X |
CHAPTER 1 - ADMINISTRATION (continued) (Matrix Adoption Tables are non-regulatory, intended only as an aid to the code user. See Chapter 1 for state agency authority and building applications.)
| Adopting Agency | BSC | BSC-CG | SFM | HCD 1 | HCD 2 | HCD 1-AC | DSA AC | DSA SS | DSA SS/CC | OSHPD 1 | OSHPD 1R | OSHPD 2 | OSHPD 3 | OSHPD 4 | OSHPD 5 | OSHPD 6 | BSCC | DPH | AGR | DWR | CEC | CA | SL | SLC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Adopt Entire Chapter | ||||||||||||||||||||||||
| Adopt Entire Chapter as amended (amended sections listed below) | ||||||||||||||||||||||||
| Adopt only those sections that are listed below | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | X | ||
| Chapter/ |
||||||||||||||||||||||||
| 1.10.4 | X | |||||||||||||||||||||||
| 1.10.5 | X | |||||||||||||||||||||||
| 1.10.6 | X | |||||||||||||||||||||||
| 1.11.0 - 1.11.11 | X | |||||||||||||||||||||||
| 1.13.0 | X | |||||||||||||||||||||||
| Division II - Scope and Administration | ||||||||||||||||||||||||
| 101.0 | X | X | X | X | X | |||||||||||||||||||
| 102.0 | X | X | X | X | X | |||||||||||||||||||
| 103.0 | X | X | X | X | X | |||||||||||||||||||
| 104.2 Items 1 & 2 | X | X | ||||||||||||||||||||||
| 104.3.1 | X | X | X | X | X | |||||||||||||||||||
| 104.4.3.1 | X | |||||||||||||||||||||||
| 105.0 | X | X | X | X | X |
This state agency does not adopt sections identified with the following symbol: The Office of the State Fire Marshal’s adoption of this chapter or individual sections is applicable to structures regulated by other state agencies pursuant to Section 1.11.0.
CHAPTER 1
ADMINISTRATION
DIVISION I
CALIFORNIA ADMINISTRATION
1.1.0 General.¶
1.2.0 Building Standards Commission.¶
1.3.0 Board of State and Community Corrections.¶
1.4.0 Department of Consumer Affairs.¶
1.5.0 Reserved for California Energy Commission.¶
1.6.0 Department of Food and Agriculture.¶
1.7.0 Department of Public Health.¶
1.8.0 Department of Housing and Community Development.¶
[HCD]
1.9.0 Division of the State Architect.¶
1.10.0 Department of Health Care Access and Information/Office of Statewide Hospital Planning and Development.¶
1.10.0 Department of Health Care Access and Informa- tion/Office of Statewide Hospital Planning and Development.
1.11.0 Office of the State Fire Marshal.¶
1.12.0 Reserved for the State Librarian.¶
1.13.0 Department of Water Resources (DWR).¶
1.14.0 Reserved for the State Lands Commission.¶
DIVISION II
SCOPE AND ADMINISTRATION
101.0 General.¶
102.0 Applicability.¶
103.0 Duties and Powers of the Authority Having Jurisdiction.¶
Jurisdiction.
104.0 Permits.¶
105.0 Inspections and Testing.¶
106.0 Violations and Penalties.¶
107.0 Board of Appeals.¶
Explained in plain English
Guides that cite this section.
Continue researching
Related topics
State and federal sources. Edit the document title or filters, then run your search.
Get a plain-English answer with a citation back to this text.
Ask AI about this code