222.0 T – — 2025 California Plumbing Code
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Plumbing Code (Title 24, Part 5) § 222.0 · Effective January 1, 2026 · Official source: Building Standards Commission
T Rating. The time period that the penetration firestop system, including the penetrating item, limits the maximum temperature rise of 325°F (181°C) above its initial temperature through the penetration on the nonfire side, where tested in accordance with ASTM E814 or UL 1479.
Tailpiece. The pipe or tubing that connects the outlet of a plumbing fixture to a trap. Testing Agency. [HCD 1] See “Approved Testing Agency”. Thermostatic (Temperature Control) Valve. A mixing valve that senses outlet temperature and compensates for fluctuations in incoming hot or cold water temperatures. Toilet. [OSHPD 1, 2, 3, 4 & 5] A fixture within a toilet room which is used for defecation or urination. Toilet Facility. A room or space containing not less than one lavatory and one water closet.
Toilet Room. [OSHPD 1, 2, 3, 4 & 5] A room within or on the premises containing water closets, urinals, and other required facilities. Transition Gas Riser. A listed or approved section or sections of pipe and fittings used to convey fuel gas and installed in a gas piping system to provide a transition from belowground to aboveground.
Trap. A fitting or device so designed and constructed as to provide, where properly vented, a liquid seal that will prevent the back passage of air without materially affecting the flow of sewage or wastewater through it.
Trap Arm. Those portions of a fixture drain between a trap and the vent.
Trap Primer. A device and system of piping that maintains a water seal in a remote trap. Trap Seal. The vertical distance between the crown weir and the top dip of the trap. Crown Weir (Trap Weir). The lowest point in the cross-section of the horizontal waterway at the exit of the trap. Top Dip (of the trap). The highest point in the internal cross-section of the trap at the lowest part of the bend (inverted siphon). By contrast, the bottom dip is the lowest point in the internal cross-section. Treated Gray Water. [BSC-CG & HCD 1] Nonpotable water meeting the definition of “gray water” collected and treated on-site suitable for direct beneficial use.
Continue researching
Related topics
State and federal sources. Edit the document title or filters, then run your search.
Get a plain-English answer with a citation back to this text.
Ask AI about this code