Skip to content

Chapter IX

SEC. 91.1900. BASIC PROVISIONS.

Los Angeles Rent Rules (LAMC excerpts) · 2025 edition · updated 2026-07-25 · Los Angeles

(Amended by Ord. No. 186,488, Eff. 12/27/19.)

Chapter 19 of the CBC is adopted by reference, except that CBC Sections 1905.1, 1905.1.7, and 1906.1 are not adopted; and, in lieu, LAMC Subsections 91.1905.1, 91.1905.1.7, 91.1905.1.9, 91.1905.1.10, 91.1905.1.11, 91.1905.1.12, 91.1906, and 91.1906.1 are added. (Amended by Ord. No. 188,739, Eff. 9/23/25.)

91.1905.1. General. The text of ACI 318 shall be modified as indicated in CBC Sections 1905.1.1 through 1905.1.8 and as modified by the LAMC.

91.1905.1.7. ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following:

14.1.4 - Plain concrete in structures assigned to Seismic Design Category C, D, E or F.

14.1.4.1 - Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows:

(a) Concrete used for fill with a minimum cement content of two (2) sacks of Portland cement per cubic yard.

(b) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness.

(c) Plain concrete footings supporting walls are permitted provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than .002 times the gross cross-sectional area of the footing. A minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections.

EXCEPTION: In detached one- and two-family dwellings three stories or less in height and constructed with stud-bearing walls, plain concrete footings with at least two continuous longitudinal reinforcement bars not smaller than No. 4 are permitted to have a total area of less than .002 times the gross cross- sectional area of the footing.

91.1905.1.9. ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5 by adding Section 18.7.5.8 to read as follows:

18.7.5.8 - Where the calculated point of contraflexure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318 Section 18.7.5.1 Items (a) through (c), over the full height of the member.

91.1905.1.10. ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding Section 18.7.5.9 to read as follows: (Amended by Ord. No. 188,739, Eff. 9/23/25

18.7.5.9 - At any section where the design strength, φP n , of the column is less than the sum of the shears V e computed in accordance with ACI 318 Sections 18.6.5.1 and 18.7.6.1.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. For beams framing into opposite sides of the column, the moment components may be assumed to be of opposite sign. For determination of the design strength, φP n , of the column, these moments may be assumed to result from the deformation of the frame in any one principal axis.

nder consideration, transverse reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. For beams framing into opposite sides of the column, the moment components may be assumed to be of opposite sign. For determination of the design strength, φP n , of the column, these moments may be assumed to result from the deformation of the frame in any one principal axis.

91.1905.1.11. ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding Section 18.10.4.6 to read as follows:

18.10.4.6 - Walls and portions of walls with P u > 0.35P o shall not be considered to contribute to the calculated strength of the structure for resisting earthquake-induced forces. Such walls shall conform to the requirements of ACI 318, Section 18.14 for wall piers.

91.1905.1.12. ACI 318, Section 18.12.6. Modify ACI 318, Section 18.12.6, by adding Section 18.12.6.2 to read as follows:

18.12.6.2 - Collector and boundary elements in topping slabs placed over precast floor and roof elements shall not be less than 3 inches (76 mm) or 6d b thick, where d b is the diameter of the largest reinforcement in the topping slab. [CBC Section 1909.3.5]

91.1906. Footings for Light-Frame Construction. (Added by Ord. No. 187,719, Eff. 1/23/23.)

91.1906.1. Plain Concrete Footings. (Amended by Ord. No. 187,719, Eff. 1/23/ 23.) The design and construction of structural plain concrete, both cast-in- place and precast, shall comply with the minimum requirements of ACI 318, as modified in CBC Section 1905.

EXCEPTION: For Group R-3 occupancies and buildings of other occupancies less than two stories above grade plane of light-frame construction, the required footing thickness of ACI 318 is permitted to be reduced to 6 inches (152 mm), provided that the footing does not extend more than 4 inches (102 mm) on either side of the supported wall. This exception shall not apply to structural elements designed to resist seismic lateral forces for structures assigned to Seismic Design Category D, E, or F.

DIVISION 20 ALUMINUM

(Division Title Amended by Ord. No. 179,324, Eff. 12/10/07, Oper. 1/1/08.)

91.2000 Basic Provisions.

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — Los Angeles Rent Rules (LAMC excerpts)
Los Angeles Rent Rules (LAMC excerpts)
  1. Chapter I
  2. Chapter IX
    Overview
    1. SEC. 91.101. TITLE, PURPOSE, AND SCOPE.
    2. SEC. 91.102. UNSAFE BUILDINGS OR STRUCTURES.
    3. SEC. 91.103. VIOLATIONS.
    4. SEC. 91.104. ORGANIZATION AND ENFORCEMENT.
    5. SEC. 91.105. APPEALS.
    6. SEC. 91.106. PERMITS.
    7. SEC. 91.107. FEES.
    8. SEC. 91.108. INSPECTION.
    9. SEC. 91.109. CERTIFICATE OF OCCUPANCY.
    10. SEC. 91.110. RESPONSIBILITY OF PERMITTEE.
    11. SEC. 91.111. CODE REVISION.
    12. SEC. 91.113. PERMIT FEES.
    13. SEC. 91.201. GENERAL.
    14. SEC. 91.202. DEFINITIONS.
    15. SEC. 91.300. BASIC PROVISIONS.
    16. SEC. 91.400. BASIC PROVISIONS.
    17. SEC. 91.500. BASIC PROVISIONS.
    18. SEC. 91.600. BASIC PROVISIONS.
    19. SEC. 91.700. BASIC PROVISIONS.
    20. SEC. 91.703. FIRE-RESISTANCE RATINGS AND FIRE TESTS.
    21. SEC. 91.800. BASIC PROVISIONS.
    22. SEC. 91.900. BASIC PROVISIONS.
    23. SEC. 91.909. SMOKE CONTROL SYSTEMS.
    24. SEC. 91.1000. BASIC PROVISIONS.
    25. SEC. 91.1100. BASIC PROVISIONS.
    26. SEC. 91.1200. BASIC PROVISIONS.
    27. SEC. 91.1206. SOUND TRANSMISSION.
    28. SEC. 91.1300. GENERAL.
    29. SEC. 91.1301. SOLAR ENERGY COLLECTORS.
    30. SEC. 91.1400. BASIC PROVISIONS.
    31. SEC. 91.1402. PERFORMANCE REQUIREMENTS.
    32. SEC. 91.1500. BASIC PROVISIONS.
    33. SEC. 91.1505. FIRE CLASSIFICATION.
    34. SEC. 91.1507. REQUIREMENTS FOR ROOF COVERINGS.
    35. SEC. 91.1511. REROOFING.
    36. SEC. 91.1600. BASIC PROVISIONS.
    37. SEC. 91.1603. CONSTRUCTION DOCUMENTS.
    38. SEC. 91.1609. WIND LOADS.
    39. SEC. 91.1612. FLOOD LOADS.
    40. SEC. 91.1613. EARTHQUAKE LOADS.
    41. SEC. 91.1700. GENERAL.
    42. SEC. 91.1702. NEW MATERIALS.
    43. SEC. 91.1703. APPROVALS.
    44. SEC. 91.1704. SPECIAL INSPECTIONS.
    45. SEC. 91.1705. REQUIRED VERIFICATION AND INSPECTION.
    46. SEC. 91.1706. DESIGN STRENGTHS OF MATERIALS.
    47. SEC. 91.1710. CERTIFIED SECURITY BAR INSTALLER.
    48. SEC. 91.1711. PREFABRICATED CONSTRUCTION.
    49. SEC. 91.1800. BASIC PROVISIONS.
    50. SEC. 91.1801. GENERAL.
    51. SEC. 91.1802. DESIGN BASIS.
    52. SEC. 91.1803. GEOTECHNICAL INVESTIGATION.
    53. SEC. 91.1804. EXCAVATION, GRADING AND FILL.
    54. SEC. 91.1805. DAMPPROOFING AND WATERPROOFING.
    55. SEC. 91.1806. PRESUMPTIVE LOAD BEARING VALUES OF SOILS.
    56. SEC. 91.1807. FOUNDATION WALLS, RETAINING WALLS, AND EMBEDDED …
    57. SEC. 91.1808. FOUNDATIONS.
    58. SEC. 91.1809. SHALLOW FOUNDATIONS.
    59. SEC. 91.1810. DEEP FOUNDATIONS..
    60. SEC. 91.1900. BASIC PROVISIONS.
    61. SEC. 91.2000. BASIC PROVISIONS.
    62. SEC. 91.2100. BASIC PROVISIONS.
    63. SEC. 91.2113. MASONRY CHIMNEYS.
    64. SEC. 91.2200. BASIC PROVISIONS.
    65. SEC. 91.2204. CONNECTIONS.
    66. SEC. 91.2300. BASIC PROVISIONS.
    67. SEC. 91.2301. GENERAL.
    68. SEC. 91.2304. GENERAL CONSTRUCTION REQUIREMENTS.
    69. SEC. 91.2305. GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RE…
    70. SEC. 91.2306. ALLOWABLE STRESS DESIGN.
    71. SEC. 91.2308. CONVENTIONAL LIGHT-FRAME CONSTRUCTION.
    72. SEC. 91.2400. BASIC PROVISIONS.
    73. SEC. 91.2503. INSPECTIONS.
    74. SEC. 91.2600. BASIC PROVISIONS.
    75. SEC. 91.2700. BASIC PROVISIONS.
    76. SEC. 91.2800. BASIC PROVISIONS.
    77. SEC. 91.2900. BASIC PROVISIONS.
    78. SEC. 91.3000. BASIC PROVISIONS.
    79. SEC. 91.3001. GENERAL.
    80. SEC. 91.3002. HOISTWAY ENCLOSURES.
    81. SEC. 91.3003. EMERGENCY OPERATIONS.
    82. SEC. 91.3004. CONVEYING SYSTEMS.
    83. SEC. 91.3005. CONVEYING SYSTEMS.
    84. SEC. 91.3007. FIRE SERVICE ACCESS ELEVATOR.
    85. SEC. 91.3008. OCCUPANT EVACUATION ELEVATORS.
    86. SEC. 91.3100. BASIC PROVISIONS.
    87. SEC. 91.3106. MARQUEES.
    88. SEC. 91.3108. TELECOMMUNICATIONS AND BROADCAST TOWERS.
    89. SEC. 91.3109. SWIMMING POOL ENCLOSURES AND SAFETY DEVICES.
    90. SEC. 91.3112. PATIO COVERS.
    91. SEC. 91.3200. BASIC PROVISIONS.
    92. SEC. 91.3201. GENERAL.
    93. SEC. 91.3202. GENERAL.
    94. SEC. 91.3300. BASIC PROVISIONS.
    95. SEC. 91.3301. GENERAL.
    96. SEC. 91.3304. SITE WORK.
    97. SEC. 91.3305. TOILET FACILITIES DURING CONSTRUCTION.
    98. SEC. 91.3306. PROTECTION OF PEDESTRIANS.
    99. SEC. 91.3307. PROTECTION OF ADJOINING PROPERTY.
    100. SEC. 91.3500. BASIC PROVISIONS.
    101. SEC. 91.6101. IMPACT HAZARD GLAZING IN EXISTING BUILDINGS.
    102. SEC. 91.6102. RUBBISH ROOMS.
    103. SEC. 91.6103. SHAFTS, PITS AND SIMILAR EXCAVATION – MISDEMEANOR.
    104. SEC. 91.6104. FIRE DISTRICTS.
    105. SEC. 91.6105. SEPARATION FROM OIL WELLS.
    106. SEC. 91.6107. TRANSFORMER VAULTS.
    107. SEC. 91.6109. SWIMMING POOLS AND OTHER BODIES OF WATER – PROTE…
    108. SEC. 91.6201. GENERAL PROVISIONS.
    109. SEC. 91.6202. DEFINITIONS.
    110. SEC. 91.6203. LOCATION.
    111. SEC. 91.6204. IDENTIFICATION.
    112. SEC. 91.6205. DESIGN AND CONSTRUCTION.
    113. SEC. 91.6206. ELECTRICAL.
    114. SEC. 91.6207. COMBUSTIBLE MATERIALS.
    115. SEC. 91.6208. ANIMATED DEVICES.
    116. SEC. 91.6209. GROUND SIGNS.
    117. SEC. 91.6210. ROOF SIGNS.
    118. SEC. 91.6211. WALL SIGNS.
    119. SEC. 91.6212. PROJECTING SIGNS.
    120. SEC. 91.6213. MARQUEE SIGNS.
    121. SEC. 91.6214. PORTABLE SIGNS.
    122. SEC. 91.6215. REFERENCED STANDARDS.
    123. SEC. 91.6216. EXISTING SIGNS.
    124. SEC. 91.6301. GENERAL.
    125. SEC. 91.6302. FOOD ESTABLISHMENT.
    126. SEC. 91.6303. SERVICE STATIONS.
    127. SEC. 91.6304. RESIDENTIAL USES.
    128. SEC. 91.6305. PARKING GARAGES SERVING RESIDENTIAL USES.
    129. SEC. 91.6306. ANTI-GRAFFITI FINISH TO EXTERIOR WALLS.
    130. SEC. 91.6307. SHOWER AND LOCKER FACILITIES.
    131. SEC. 91.6701. PURPOSE.
    132. SEC. 91.6702. GENERAL.
    133. SEC. 91.6703. LIMITATIONS.
    134. SEC. 91.6704. ALTERNATE SECURITY PROVISIONS.
    135. SEC. 91.6705. DEFINITIONS.
    136. SEC. 91.6706. ENTRY VISION.
    137. SEC. 91.6707. APPURTENANT ACCESS.
    138. SEC. 91.6708. DOORS – GENERAL.
    139. SEC. 91.6709. SWINGING DOORS.
    140. SEC. 91.6710. SLIDING GLASS DOORS.
    141. SEC. 91.6711. OVERHEAD AND SLIDING DOORS.
    142. SEC. 91.6712. METAL ACCORDION-GRATE OR GRILLE-TYPE DOORS.
    143. SEC. 91.6713. GLAZED OPENING – GENERAL.
    144. SEC. 91.6714. GLAZING.
    145. SEC. 91.6715. WINDOWS.
    146. SEC. 91.6716. OPENINGS OTHER THAN DOORS OR GLAZED OPENINGS.
    147. SEC. 91.6717. TESTS – GENERAL.
    148. SEC. 91.7001. PURPOSE.
    149. SEC. 91.7002. SCOPE.
    150. SEC. 91.7003. DEFINITIONS.
    151. SEC. 91.7004. GRADING DESIGNATION.
    152. SEC. 91.7005. GENERAL REQUIREMENTS.
    153. SEC. 91.7006. CONDITIONS PRECEDENT TO ISSUING A GRADING PERMIT.
    154. SEC. 91.7007. SAFETY PRECAUTIONS DURING GRADING.
    155. SEC. 91.7008. PROFESSIONAL INSPECTION AND CERTIFICATION FOR EN…
    156. SEC. 91.7009. PROFESSIONAL INSPECTION FOR REGULAR GRADING.
    157. SEC. 91.7010. EXCAVATIONS.
    158. SEC. 91.7011. FILLS.
    159. SEC. 91.7012. PLANTING AND IRRIGATION OF CUT AND FILL SLOPES I…
    160. SEC. 91.7013. EROSION CONTROL AND DRAINAGE DEVICES.
    161. SEC. 91.7014. CONSTRUCTION REQUIREMENTS AND LIMITATIONS.
    162. SEC. 91.7015. BUTTRESS FILLS.
    163. SEC. 91.7016. AREAS SUBJECTED TO SLIDES AND UNSTABLE SOIL.
    164. SEC. 91.7101. PURPOSE.
    165. SEC. 91.7102. DEFINITIONS.
    166. SEC. 91.7103. GENERAL METHANE MITIGATION REQUIREMENTS.
    167. SEC. 91.7104. GENERAL METHANE REQUIREMENTS.
    168. SEC. 91.7105. EXISTING BUILDINGS.
    169. SEC. 91.7106. TESTING, MAINTENANCE AND SERVICE OF GAS-DETECTIO…
    170. SEC. 91.7107. EMERGENCY PROCEDURES.
    171. SEC. 91.7108. APPLICATION OF METHANE SEEPAGE REGULATIONS TO LO…
    172. SEC. 91.7109. ADDITIONAL REMEDIAL MEASURES.
    173. SEC. 91.7200. PURPOSE.
    174. SEC. 91.7201. GENERAL.
    175. SEC. 91.7202. ADDITIONS TO BUILDINGS.
    176. SEC. 91.7203. GENERAL REQUIREMENTS.
    177. SEC. 91.7204. SPECIAL REQUIREMENTS FOR FIRE DISTRICT NUMBER 1.
    178. SEC. 91.7205. PROVISIONAL STRUCTURES.
    179. SEC. 91.7207. SPECIAL REQUIREMENTS FOR THE VERY HIGH FIRE HAZA…
    180. SEC. 91.7208. PROHIBITED VEHICLES.
    181. SEC. 91.8101. GENERAL PROVISIONS.
    182. SEC. 91.8102. ENFORCEMENT.
    183. SEC. 91.8103. EXISTING BUILDING RIGHTS.
    184. SEC. 91.8104. BASIC MAINTENANCE AND REPAIR OF EXISTING BUILDIN…
    185. SEC. 91.8105. ILLEGAL BUILDINGS, CONSTRUCTION AND USE.
    186. SEC. 91.8106. FIRE DISTRICT REQUIREMENTS.
    187. SEC. 91.8108. NUISANCES, HAZARDOUS BUILDINGS AND SUBSTANDARD R…
    188. SEC. 91.8109. RELOCATED BUILDINGS.
    189. SEC. 91.8110. UNREINFORCED MASONRY BEARING WALL BUILDINGS.
    190. SEC. 91.8111. RESIDENTIAL HEATING.
    191. SEC. 91.8112. RESIDENTIAL PLUMBING.
    192. SEC. 91.8113. ROD BRACING SYSTEMS.
    193. SEC. 91.8114. PARAPETS AND APPENDAGES.
    194. SEC. 91.8115. SANDBLASTING.
    195. SEC. 91.8116. SPECIAL PROVISIONS FOR LIGHT-HOUSEKEEPING ROOMS.
    196. SEC. 91.8117. FIRE WATCH.
    197. SEC. 91.8118. POOL WATER CLARITY.
    198. SEC. 91.8119. HISTORICAL BUILDINGS AND STRUCTURES.
    199. SEC. 91.8201. GENERAL.
    200. SEC. 91.8202. CHANGE OF RATING CLASSIFICATION.
    201. SEC. 91.8203. CHANGE OF OCCUPANCY GROUP OR GROUP DIVISION.
    202. SEC. 91.8204. CHANGE OF USE.
    203. SEC. 91.8205. CERTIFICATE OF BUILDING COMPLIANCE.
    204. SEC. 91.8301. GENERAL APPLICATION.
    205. SEC. 91.8302. PERMITS REQUIRED – GENERAL CONSIDERATIONS.
    206. SEC. 91.8303. PERMIT APPLICATION – PLANS AND SPECIFICATIONS.
    207. SEC. 91.8304. SPECIAL CONDITIONS UNDER WHICH A PERMIT WILL NOT…
    208. SEC. 91.8305. GUARANTEE OF COMPLETION REQUIRED.
    209. SEC. 91.8306. TERMS OF PERMIT.
    210. SEC. 91.8307. DEFAULT IN PERFORMANCE OF CONDITIONS OR TERMS OF…
    211. SEC. 91.8308. PERMIT FEES.
    212. SEC. 91.8309. ENTRY UPON PREMISES.
    213. SEC. 91.8501. GENERAL.
    214. SEC. 91.8502. ALTERNATIVE STANDARDS.
    215. SEC. 91.8601. GENERAL.
    216. SEC. 91.8602. GROUP E OCCUPANCIES.
    217. SEC. 91.8603. FIRE PROTECTION – WARNING SYSTEM.
    218. SEC. 91.8604. FIRE SAFETY STANDARDS.
    219. SEC. 91.8605. EMERGENCY HOMELESS SHELTERS.
    220. SEC. 91.8606. EMERGENCY LIGHTING STANDARDS FOR EXISTING RESIDE…
    221. SEC. 91.8607. TENANT SAFETY FOR APARTMENT HOUSES, EXCEPT FOR R…
    222. SEC. 91.8801. PURPOSE.
    223. SEC. 91.8802. SCOPE.
    224. SEC. 91.8803. DEFINITIONS.
    225. SEC. 91.8804. RATING CLASSIFICATIONS.
    226. SEC. 91.8805. GENERAL REQUIREMENTS.
    227. SEC. 91.8806. ADMINISTRATION.
    228. SEC. 91.8807. HISTORICAL BUILDINGS.
    229. SEC. 91.8808. ANALYSIS AND DESIGN.
    230. SEC. 91.8809. MATERIALS OF CONSTRUCTION.
    231. SEC. 91.8810. INFORMATION REQUIRED ON PLANS.
    232. SEC. 91.8811. DESIGN CHECK – COMPATIBILITY OF ROOF DIAPHRAGM S…
    233. SEC. 91.8812. VIOLATIONS.
    234. SEC. 91.8813. SPECIAL REQUIREMENTS FOR VACANT BUILDINGS.
    235. SEC. 91.8901. GENERAL.
    236. SEC. 91.8902. DEFINITIONS.
    237. SEC. 91.8903. ABATEMENT PROCEDURES.
    238. SEC. 91.8903 Los Angeles Municipal Code.
    239. SEC. 91.8904. SPECIAL PROVISIONS FOR VACANT PROPERTY GRAFFITI …
    240. SEC. 91.8905. SPECIAL PROVISIONS FOR VACATING, BARRICADING, RE…
    241. SEC. 91.8906. PAYMENT AND RECOVERY OF REPAIR AND DEMOLITION FU…
    242. SEC. 91.8907. ABATEMENT OF PUBLIC NUISANCE CONDITIONS RELATED …
    243. SEC. 91.8908. SPECIAL PROVISIONS FOR THE REPAIR OF WELDED STEE…
    244. SEC. 91.8910. PROCEDURE FOR ABATEMENT OF NUISANCE; RECOVERY OF…
    245. SEC. 91.9001. GENERAL.
    246. SEC. 91.9002. DEFINITIONS.
    247. SEC. 91.9003. ABATEMENT PROCEDURES.
    248. SEC. 91.9101. PURPOSE.
    249. SEC. 91.9102. SCOPE.
    250. SEC. 91.9103. DEFINITIONS.
    251. SEC. 91.9104. RATING CLASSIFICATIONS.
    252. SEC. 91.9105. GENERAL REQUIREMENTS.
    253. SEC. 91.9106. ADMINISTRATION.
    254. SEC. 91.9107. HISTORICAL BUILDINGS.
    255. SEC. 91.9108. ANALYSIS AND DESIGN.
    256. SEC. 91.9109. MATERIALS OF CONSTRUCTION.
    257. SEC. 91.9110. INFORMATION REQUIRED ON PLANS.
    258. SEC. 91.9111. REQUIRED BUILDING MAINTENANCE.
    259. SEC. 91.9112. VIOLATIONS – PENALTIES FOR DISREGARDING DEPARTME…
    260. SEC. 91.9201. GENERAL.
    261. SEC. 91.9202. DEFINITIONS.
    262. SEC. 91.9203. STRUCTURAL WEAKNESSES.
    263. SEC. 91.9204. STRENGTHENING REQUIREMENTS.
    264. SEC. 91.9205. QUALITY CONTROL.
    265. SEC. 91.9301. PURPOSE.
    266. SEC. 91.9302. SCOPE.
    267. SEC. 91.9303. DEFINITIONS.
    268. SEC. 91.9304. PRIORITY DESIGNATIONS.
    269. SEC. 91.9305. COMPLIANCE REQUIREMENTS.
    270. SEC. 91.9306. ADMINISTRATION.
    271. SEC. 91.9307. OCCUPANT AND TENANT ADVISORY.
    272. SEC. 91.9308. HISTORICAL BULDINGS.
    273. SEC. 91.9309. ENGINEERING ANALYSIS.
    274. SEC. 91.9310. INFORMATION REQUIRED ON PLANS.
    275. SEC. 91.9311. VIOLATION / PENALTY.
    276. SEC. 91.9312. SEVERABILITY.
    277. SEC. 91.9401. PURPOSE.
    278. SEC. 91.9402. SCOPE.
    279. SEC. 91.9403. DEFINITIONS.
    280. SEC. 91.9404. GENERAL REQUIREMENTS.
    281. SEC. 91.9405. PRE-DESIGN INVESTIGATION.
    282. SEC. 91.9406. ANALYSIS AND DESIGN.
    283. SEC. 91.9407. HISTORICAL BUILDINGS.
    284. SEC. 91.9408. QUALITY CONTROL.
    285. SEC. 91.9409. INFORMATION REQUIRED ON PLANS.
    286. SEC. 91.9501. PURPOSE.
    287. SEC. 91.9502. SCOPE.
    288. SEC. 91.9503. DEFINITIONS.
    289. SEC. 91.9504. COMPLIANCE REQUIREMENTS.
    290. SEC. 91.9505. ADMINISTRATION.
    291. SEC. 91.9506. OCCUPANT AND TENANT ADVISORY.
    292. SEC. 91.9507. HISTORICAL BUILDINGS.
    293. SEC. 91.9508. ENGINEERING ANALYSIS.
    294. SEC. 91.9509. INFORMATION REQUIRED ON PLANS.
    295. SEC. 91.9510. VIOLATION / PENALTY.
    296. SEC. 91.9511. SEVERABILITY.
    297. SEC. 91.9601. PURPOSE.
    298. SEC. 91.9602. SCOPE.
    299. SEC. 91.9603. DEFINITIONS.
    300. SEC. 91.9604. ANALYSIS AND DESIGN.
    301. SEC. 91.9605. MATERIALS OF CONSTRUCTION.
    302. SEC. 91.9606. INFORMATION REQUIRED ON PLANS.
    303. SEC. 91.9701. TITLE.
    304. SEC. 91.9702. PURPOSE.
    305. SEC. 91.9703. SCOPE.
    306. SEC. 91.9704. DEFINITIONS.
    307. SEC. 91.9705. BENCHMARKING AND SELF-REPORTING OF ENERGY AND WA…
    308. SEC. 91.9706. ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING.
    309. SEC. 91.9707. RECORD MAINTENANCE.
    310. SEC. 91.9708. SCHEDULE FOR COMPLIANCE.
    311. SEC. 91.9709. NONCOMPLIANCE FEE.
    312. SEC. 91.9710. SUBMITTAL FEES.
    313. SEC. 91.9711. BUILDING AND SAFETY DEVELOPMENT SURCHARGE.
    314. SEC. 91.9712. SEVERABILITY.
    315. Article 1.2
    316. Article 1.5
    317. Article 7
    318. Article 8
    319. Article 9
  3. Chapter XV
  4. Chapter XVI

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.