SEC. 91.2306. ALLOWABLE STRESS DESIGN.
Los Angeles Rent Rules (LAMC excerpts) · 2025 edition · updated 2026-07-25 · Los Angeles
(Amended by Ord. No. 182,850, Eff. 1/3/14.)
Section 2306 of the CBC is adopted by reference, except that Sections 2306.2 and 2306.3 of the CBC are not adopted; and, in lieu, LAMC Subsections 91.2306.2, 91.2306.3, and 91.2306.4 are added. (Amended by Ord. No. 185,587, Eff. 7/16/18.)
91.2306.2. Wood-Frame Diaphragms. (Amended by Ord. No. 185,587, Eff. 7/16/18.) Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC DPWS shall be met and the allowable shear values set forth in CBC Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B or C.
EXCEPTION: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.
The allowable shear values of CBC Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40% for wind design.
Wood structural panel diaphragms used to resist seismic forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members.
EXCEPTION: Wood structural panel diaphragm is permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking joints do not coincide.
91.2306.3. Wood-Frame Shear Walls. (Amended by Ord. No. 186,488, Eff. 12/27/ 19.) Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Tables 4.3A and 4.3B of AWC SDPWS shall include the following:
Wood structural panel thickness for shear walls shall not be less than 3/8 inch (9.525 mm) thick, and studs shall not be spaced at more than 16 inches (406.4 mm) on center.
The maximum nominal unit shear capacities for three-ply plywood resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 400 pounds per linear foot (plf) (181.43 kg per meter).
3. Where shear design values using allowable stress design (ASD) exceed
350 plf or load and resistance factor design (LRFD) exceed 500 plf, all framing members receiving edge nailing from abutting panels shall not be less than a single 3 inch (76.19 mm) nominal member, or two 2 inch (50.8 mm) nominal members fastened together in accordance with CBC Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Sections 4.3.6.1 and 4.3.6.4.3 of AWC SDPWS for sill plate size and anchorage requirements.
ot be less than a single 3 inch (76.19 mm) nominal member, or two 2 inch (50.8 mm) nominal members fastened together in accordance with CBC Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Sections 4.3.6.1 and 4.3.6.4.3 of AWC SDPWS for sill plate size and anchorage requirements.
Nails shall be placed not less than 1/2 inch (12.7 mm) in from the panel edges and not less than 3/8 inch (9.525 mm) from the edge of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be placed not less than 3/8 inch (9.525 mm) from panel edges and not less than 1/4 inch (6.35 mm) from the edge of the connecting members for shears of 350 plf or less using ASD or 500 plf or less using LRFD.
Table 4.3B of AWC SDPWS application is not allowed for structures assigned to Seismic design category D, E or F.
For structures assigned to Seismic Design Category D, Application of Table 4.3C of AWC SDPWS shall not be used below the top level in a multi-level building for structures.
Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in CBC Tables 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B or C.
EXCEPTION: Where panels are fastened to framing members with staples, allowable shear values may be used if such values are substantiated by cyclic testing and approved by the Superintendent of Building.
The allowable shear values in CBC Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40% for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS.
91.2306.4. Shear Walls Sheathed with Other Materials. Sheer walls sheathed with Portland cement plaster, gypsum lath, gypsum sheathing or gypsum board shall be designed and constructed in accordance with AWC SDPWS. Shear walls sheathed with these materials are permitted to resist horizontal forces using the allowable shear capacities set forth in CBC Table 2306.3(3). Shear walls sheathed with Portland cement plaster, gypsum lath, gypsum sheathing or gypsum board shall not be used to resist seismic forces in structures assigned to Seismic Design Category E or F. (Amended by Ord. No. 186,488, Eff. 12/27/19.)
Shear walls sheathed with lath, plaster or gypsum board shall not be used below the top level in a multi-level building for structures assigned to Seismic Design Category D.
Get a plain-English answer with a citation back to this text.
Ask AI about this code▸ Contents — Los Angeles Rent Rules (LAMC excerpts)
- Chapter I
-
▸ Chapter IX
Overview- SEC. 91.101. TITLE, PURPOSE, AND SCOPE.
- SEC. 91.102. UNSAFE BUILDINGS OR STRUCTURES.
- SEC. 91.103. VIOLATIONS.
- SEC. 91.104. ORGANIZATION AND ENFORCEMENT.
- SEC. 91.105. APPEALS.
- SEC. 91.106. PERMITS.
- SEC. 91.107. FEES.
- SEC. 91.108. INSPECTION.
- SEC. 91.109. CERTIFICATE OF OCCUPANCY.
- SEC. 91.110. RESPONSIBILITY OF PERMITTEE.
- SEC. 91.111. CODE REVISION.
- SEC. 91.113. PERMIT FEES.
- SEC. 91.201. GENERAL.
- SEC. 91.202. DEFINITIONS.
- SEC. 91.300. BASIC PROVISIONS.
- SEC. 91.400. BASIC PROVISIONS.
- SEC. 91.500. BASIC PROVISIONS.
- SEC. 91.600. BASIC PROVISIONS.
- SEC. 91.700. BASIC PROVISIONS.
- SEC. 91.703. FIRE-RESISTANCE RATINGS AND FIRE TESTS.
- SEC. 91.800. BASIC PROVISIONS.
- SEC. 91.900. BASIC PROVISIONS.
- SEC. 91.909. SMOKE CONTROL SYSTEMS.
- SEC. 91.1000. BASIC PROVISIONS.
- SEC. 91.1100. BASIC PROVISIONS.
- SEC. 91.1200. BASIC PROVISIONS.
- SEC. 91.1206. SOUND TRANSMISSION.
- SEC. 91.1300. GENERAL.
- SEC. 91.1301. SOLAR ENERGY COLLECTORS.
- SEC. 91.1400. BASIC PROVISIONS.
- SEC. 91.1402. PERFORMANCE REQUIREMENTS.
- SEC. 91.1500. BASIC PROVISIONS.
- SEC. 91.1505. FIRE CLASSIFICATION.
- SEC. 91.1507. REQUIREMENTS FOR ROOF COVERINGS.
- SEC. 91.1511. REROOFING.
- SEC. 91.1600. BASIC PROVISIONS.
- SEC. 91.1603. CONSTRUCTION DOCUMENTS.
- SEC. 91.1609. WIND LOADS.
- SEC. 91.1612. FLOOD LOADS.
- SEC. 91.1613. EARTHQUAKE LOADS.
- SEC. 91.1700. GENERAL.
- SEC. 91.1702. NEW MATERIALS.
- SEC. 91.1703. APPROVALS.
- SEC. 91.1704. SPECIAL INSPECTIONS.
- SEC. 91.1705. REQUIRED VERIFICATION AND INSPECTION.
- SEC. 91.1706. DESIGN STRENGTHS OF MATERIALS.
- SEC. 91.1710. CERTIFIED SECURITY BAR INSTALLER.
- SEC. 91.1711. PREFABRICATED CONSTRUCTION.
- SEC. 91.1800. BASIC PROVISIONS.
- SEC. 91.1801. GENERAL.
- SEC. 91.1802. DESIGN BASIS.
- SEC. 91.1803. GEOTECHNICAL INVESTIGATION.
- SEC. 91.1804. EXCAVATION, GRADING AND FILL.
- SEC. 91.1805. DAMPPROOFING AND WATERPROOFING.
- SEC. 91.1806. PRESUMPTIVE LOAD BEARING VALUES OF SOILS.
- SEC. 91.1807. FOUNDATION WALLS, RETAINING WALLS, AND EMBEDDED …
- SEC. 91.1808. FOUNDATIONS.
- SEC. 91.1809. SHALLOW FOUNDATIONS.
- SEC. 91.1810. DEEP FOUNDATIONS..
- SEC. 91.1900. BASIC PROVISIONS.
- SEC. 91.2000. BASIC PROVISIONS.
- SEC. 91.2100. BASIC PROVISIONS.
- SEC. 91.2113. MASONRY CHIMNEYS.
- SEC. 91.2200. BASIC PROVISIONS.
- SEC. 91.2204. CONNECTIONS.
- SEC. 91.2300. BASIC PROVISIONS.
- SEC. 91.2301. GENERAL.
- SEC. 91.2304. GENERAL CONSTRUCTION REQUIREMENTS.
- SEC. 91.2305. GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RE…
- SEC. 91.2306. ALLOWABLE STRESS DESIGN.
- SEC. 91.2308. CONVENTIONAL LIGHT-FRAME CONSTRUCTION.
- SEC. 91.2400. BASIC PROVISIONS.
- SEC. 91.2503. INSPECTIONS.
- SEC. 91.2600. BASIC PROVISIONS.
- SEC. 91.2700. BASIC PROVISIONS.
- SEC. 91.2800. BASIC PROVISIONS.
- SEC. 91.2900. BASIC PROVISIONS.
- SEC. 91.3000. BASIC PROVISIONS.
- SEC. 91.3001. GENERAL.
- SEC. 91.3002. HOISTWAY ENCLOSURES.
- SEC. 91.3003. EMERGENCY OPERATIONS.
- SEC. 91.3004. CONVEYING SYSTEMS.
- SEC. 91.3005. CONVEYING SYSTEMS.
- SEC. 91.3007. FIRE SERVICE ACCESS ELEVATOR.
- SEC. 91.3008. OCCUPANT EVACUATION ELEVATORS.
- SEC. 91.3100. BASIC PROVISIONS.
- SEC. 91.3106. MARQUEES.
- SEC. 91.3108. TELECOMMUNICATIONS AND BROADCAST TOWERS.
- SEC. 91.3109. SWIMMING POOL ENCLOSURES AND SAFETY DEVICES.
- SEC. 91.3112. PATIO COVERS.
- SEC. 91.3200. BASIC PROVISIONS.
- SEC. 91.3201. GENERAL.
- SEC. 91.3202. GENERAL.
- SEC. 91.3300. BASIC PROVISIONS.
- SEC. 91.3301. GENERAL.
- SEC. 91.3304. SITE WORK.
- SEC. 91.3305. TOILET FACILITIES DURING CONSTRUCTION.
- SEC. 91.3306. PROTECTION OF PEDESTRIANS.
- SEC. 91.3307. PROTECTION OF ADJOINING PROPERTY.
- SEC. 91.3500. BASIC PROVISIONS.
- SEC. 91.6101. IMPACT HAZARD GLAZING IN EXISTING BUILDINGS.
- SEC. 91.6102. RUBBISH ROOMS.
- SEC. 91.6103. SHAFTS, PITS AND SIMILAR EXCAVATION – MISDEMEANOR.
- SEC. 91.6104. FIRE DISTRICTS.
- SEC. 91.6105. SEPARATION FROM OIL WELLS.
- SEC. 91.6107. TRANSFORMER VAULTS.
- SEC. 91.6109. SWIMMING POOLS AND OTHER BODIES OF WATER – PROTE…
- SEC. 91.6201. GENERAL PROVISIONS.
- SEC. 91.6202. DEFINITIONS.
- SEC. 91.6203. LOCATION.
- SEC. 91.6204. IDENTIFICATION.
- SEC. 91.6205. DESIGN AND CONSTRUCTION.
- SEC. 91.6206. ELECTRICAL.
- SEC. 91.6207. COMBUSTIBLE MATERIALS.
- SEC. 91.6208. ANIMATED DEVICES.
- SEC. 91.6209. GROUND SIGNS.
- SEC. 91.6210. ROOF SIGNS.
- SEC. 91.6211. WALL SIGNS.
- SEC. 91.6212. PROJECTING SIGNS.
- SEC. 91.6213. MARQUEE SIGNS.
- SEC. 91.6214. PORTABLE SIGNS.
- SEC. 91.6215. REFERENCED STANDARDS.
- SEC. 91.6216. EXISTING SIGNS.
- SEC. 91.6301. GENERAL.
- SEC. 91.6302. FOOD ESTABLISHMENT.
- SEC. 91.6303. SERVICE STATIONS.
- SEC. 91.6304. RESIDENTIAL USES.
- SEC. 91.6305. PARKING GARAGES SERVING RESIDENTIAL USES.
- SEC. 91.6306. ANTI-GRAFFITI FINISH TO EXTERIOR WALLS.
- SEC. 91.6307. SHOWER AND LOCKER FACILITIES.
- SEC. 91.6701. PURPOSE.
- SEC. 91.6702. GENERAL.
- SEC. 91.6703. LIMITATIONS.
- SEC. 91.6704. ALTERNATE SECURITY PROVISIONS.
- SEC. 91.6705. DEFINITIONS.
- SEC. 91.6706. ENTRY VISION.
- SEC. 91.6707. APPURTENANT ACCESS.
- SEC. 91.6708. DOORS – GENERAL.
- SEC. 91.6709. SWINGING DOORS.
- SEC. 91.6710. SLIDING GLASS DOORS.
- SEC. 91.6711. OVERHEAD AND SLIDING DOORS.
- SEC. 91.6712. METAL ACCORDION-GRATE OR GRILLE-TYPE DOORS.
- SEC. 91.6713. GLAZED OPENING – GENERAL.
- SEC. 91.6714. GLAZING.
- SEC. 91.6715. WINDOWS.
- SEC. 91.6716. OPENINGS OTHER THAN DOORS OR GLAZED OPENINGS.
- SEC. 91.6717. TESTS – GENERAL.
- SEC. 91.7001. PURPOSE.
- SEC. 91.7002. SCOPE.
- SEC. 91.7003. DEFINITIONS.
- SEC. 91.7004. GRADING DESIGNATION.
- SEC. 91.7005. GENERAL REQUIREMENTS.
- SEC. 91.7006. CONDITIONS PRECEDENT TO ISSUING A GRADING PERMIT.
- SEC. 91.7007. SAFETY PRECAUTIONS DURING GRADING.
- SEC. 91.7008. PROFESSIONAL INSPECTION AND CERTIFICATION FOR EN…
- SEC. 91.7009. PROFESSIONAL INSPECTION FOR REGULAR GRADING.
- SEC. 91.7010. EXCAVATIONS.
- SEC. 91.7011. FILLS.
- SEC. 91.7012. PLANTING AND IRRIGATION OF CUT AND FILL SLOPES I…
- SEC. 91.7013. EROSION CONTROL AND DRAINAGE DEVICES.
- SEC. 91.7014. CONSTRUCTION REQUIREMENTS AND LIMITATIONS.
- SEC. 91.7015. BUTTRESS FILLS.
- SEC. 91.7016. AREAS SUBJECTED TO SLIDES AND UNSTABLE SOIL.
- SEC. 91.7101. PURPOSE.
- SEC. 91.7102. DEFINITIONS.
- SEC. 91.7103. GENERAL METHANE MITIGATION REQUIREMENTS.
- SEC. 91.7104. GENERAL METHANE REQUIREMENTS.
- SEC. 91.7105. EXISTING BUILDINGS.
- SEC. 91.7106. TESTING, MAINTENANCE AND SERVICE OF GAS-DETECTIO…
- SEC. 91.7107. EMERGENCY PROCEDURES.
- SEC. 91.7108. APPLICATION OF METHANE SEEPAGE REGULATIONS TO LO…
- SEC. 91.7109. ADDITIONAL REMEDIAL MEASURES.
- SEC. 91.7200. PURPOSE.
- SEC. 91.7201. GENERAL.
- SEC. 91.7202. ADDITIONS TO BUILDINGS.
- SEC. 91.7203. GENERAL REQUIREMENTS.
- SEC. 91.7204. SPECIAL REQUIREMENTS FOR FIRE DISTRICT NUMBER 1.
- SEC. 91.7205. PROVISIONAL STRUCTURES.
- SEC. 91.7207. SPECIAL REQUIREMENTS FOR THE VERY HIGH FIRE HAZA…
- SEC. 91.7208. PROHIBITED VEHICLES.
- SEC. 91.8101. GENERAL PROVISIONS.
- SEC. 91.8102. ENFORCEMENT.
- SEC. 91.8103. EXISTING BUILDING RIGHTS.
- SEC. 91.8104. BASIC MAINTENANCE AND REPAIR OF EXISTING BUILDIN…
- SEC. 91.8105. ILLEGAL BUILDINGS, CONSTRUCTION AND USE.
- SEC. 91.8106. FIRE DISTRICT REQUIREMENTS.
- SEC. 91.8108. NUISANCES, HAZARDOUS BUILDINGS AND SUBSTANDARD R…
- SEC. 91.8109. RELOCATED BUILDINGS.
- SEC. 91.8110. UNREINFORCED MASONRY BEARING WALL BUILDINGS.
- SEC. 91.8111. RESIDENTIAL HEATING.
- SEC. 91.8112. RESIDENTIAL PLUMBING.
- SEC. 91.8113. ROD BRACING SYSTEMS.
- SEC. 91.8114. PARAPETS AND APPENDAGES.
- SEC. 91.8115. SANDBLASTING.
- SEC. 91.8116. SPECIAL PROVISIONS FOR LIGHT-HOUSEKEEPING ROOMS.
- SEC. 91.8117. FIRE WATCH.
- SEC. 91.8118. POOL WATER CLARITY.
- SEC. 91.8119. HISTORICAL BUILDINGS AND STRUCTURES.
- SEC. 91.8201. GENERAL.
- SEC. 91.8202. CHANGE OF RATING CLASSIFICATION.
- SEC. 91.8203. CHANGE OF OCCUPANCY GROUP OR GROUP DIVISION.
- SEC. 91.8204. CHANGE OF USE.
- SEC. 91.8205. CERTIFICATE OF BUILDING COMPLIANCE.
- SEC. 91.8301. GENERAL APPLICATION.
- SEC. 91.8302. PERMITS REQUIRED – GENERAL CONSIDERATIONS.
- SEC. 91.8303. PERMIT APPLICATION – PLANS AND SPECIFICATIONS.
- SEC. 91.8304. SPECIAL CONDITIONS UNDER WHICH A PERMIT WILL NOT…
- SEC. 91.8305. GUARANTEE OF COMPLETION REQUIRED.
- SEC. 91.8306. TERMS OF PERMIT.
- SEC. 91.8307. DEFAULT IN PERFORMANCE OF CONDITIONS OR TERMS OF…
- SEC. 91.8308. PERMIT FEES.
- SEC. 91.8309. ENTRY UPON PREMISES.
- SEC. 91.8501. GENERAL.
- SEC. 91.8502. ALTERNATIVE STANDARDS.
- SEC. 91.8601. GENERAL.
- SEC. 91.8602. GROUP E OCCUPANCIES.
- SEC. 91.8603. FIRE PROTECTION – WARNING SYSTEM.
- SEC. 91.8604. FIRE SAFETY STANDARDS.
- SEC. 91.8605. EMERGENCY HOMELESS SHELTERS.
- SEC. 91.8606. EMERGENCY LIGHTING STANDARDS FOR EXISTING RESIDE…
- SEC. 91.8607. TENANT SAFETY FOR APARTMENT HOUSES, EXCEPT FOR R…
- SEC. 91.8801. PURPOSE.
- SEC. 91.8802. SCOPE.
- SEC. 91.8803. DEFINITIONS.
- SEC. 91.8804. RATING CLASSIFICATIONS.
- SEC. 91.8805. GENERAL REQUIREMENTS.
- SEC. 91.8806. ADMINISTRATION.
- SEC. 91.8807. HISTORICAL BUILDINGS.
- SEC. 91.8808. ANALYSIS AND DESIGN.
- SEC. 91.8809. MATERIALS OF CONSTRUCTION.
- SEC. 91.8810. INFORMATION REQUIRED ON PLANS.
- SEC. 91.8811. DESIGN CHECK – COMPATIBILITY OF ROOF DIAPHRAGM S…
- SEC. 91.8812. VIOLATIONS.
- SEC. 91.8813. SPECIAL REQUIREMENTS FOR VACANT BUILDINGS.
- SEC. 91.8901. GENERAL.
- SEC. 91.8902. DEFINITIONS.
- SEC. 91.8903. ABATEMENT PROCEDURES.
- SEC. 91.8903 Los Angeles Municipal Code.
- SEC. 91.8904. SPECIAL PROVISIONS FOR VACANT PROPERTY GRAFFITI …
- SEC. 91.8905. SPECIAL PROVISIONS FOR VACATING, BARRICADING, RE…
- SEC. 91.8906. PAYMENT AND RECOVERY OF REPAIR AND DEMOLITION FU…
- SEC. 91.8907. ABATEMENT OF PUBLIC NUISANCE CONDITIONS RELATED …
- SEC. 91.8908. SPECIAL PROVISIONS FOR THE REPAIR OF WELDED STEE…
- SEC. 91.8910. PROCEDURE FOR ABATEMENT OF NUISANCE; RECOVERY OF…
- SEC. 91.9001. GENERAL.
- SEC. 91.9002. DEFINITIONS.
- SEC. 91.9003. ABATEMENT PROCEDURES.
- SEC. 91.9101. PURPOSE.
- SEC. 91.9102. SCOPE.
- SEC. 91.9103. DEFINITIONS.
- SEC. 91.9104. RATING CLASSIFICATIONS.
- SEC. 91.9105. GENERAL REQUIREMENTS.
- SEC. 91.9106. ADMINISTRATION.
- SEC. 91.9107. HISTORICAL BUILDINGS.
- SEC. 91.9108. ANALYSIS AND DESIGN.
- SEC. 91.9109. MATERIALS OF CONSTRUCTION.
- SEC. 91.9110. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9111. REQUIRED BUILDING MAINTENANCE.
- SEC. 91.9112. VIOLATIONS – PENALTIES FOR DISREGARDING DEPARTME…
- SEC. 91.9201. GENERAL.
- SEC. 91.9202. DEFINITIONS.
- SEC. 91.9203. STRUCTURAL WEAKNESSES.
- SEC. 91.9204. STRENGTHENING REQUIREMENTS.
- SEC. 91.9205. QUALITY CONTROL.
- SEC. 91.9301. PURPOSE.
- SEC. 91.9302. SCOPE.
- SEC. 91.9303. DEFINITIONS.
- SEC. 91.9304. PRIORITY DESIGNATIONS.
- SEC. 91.9305. COMPLIANCE REQUIREMENTS.
- SEC. 91.9306. ADMINISTRATION.
- SEC. 91.9307. OCCUPANT AND TENANT ADVISORY.
- SEC. 91.9308. HISTORICAL BULDINGS.
- SEC. 91.9309. ENGINEERING ANALYSIS.
- SEC. 91.9310. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9311. VIOLATION / PENALTY.
- SEC. 91.9312. SEVERABILITY.
- SEC. 91.9401. PURPOSE.
- SEC. 91.9402. SCOPE.
- SEC. 91.9403. DEFINITIONS.
- SEC. 91.9404. GENERAL REQUIREMENTS.
- SEC. 91.9405. PRE-DESIGN INVESTIGATION.
- SEC. 91.9406. ANALYSIS AND DESIGN.
- SEC. 91.9407. HISTORICAL BUILDINGS.
- SEC. 91.9408. QUALITY CONTROL.
- SEC. 91.9409. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9501. PURPOSE.
- SEC. 91.9502. SCOPE.
- SEC. 91.9503. DEFINITIONS.
- SEC. 91.9504. COMPLIANCE REQUIREMENTS.
- SEC. 91.9505. ADMINISTRATION.
- SEC. 91.9506. OCCUPANT AND TENANT ADVISORY.
- SEC. 91.9507. HISTORICAL BUILDINGS.
- SEC. 91.9508. ENGINEERING ANALYSIS.
- SEC. 91.9509. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9510. VIOLATION / PENALTY.
- SEC. 91.9511. SEVERABILITY.
- SEC. 91.9601. PURPOSE.
- SEC. 91.9602. SCOPE.
- SEC. 91.9603. DEFINITIONS.
- SEC. 91.9604. ANALYSIS AND DESIGN.
- SEC. 91.9605. MATERIALS OF CONSTRUCTION.
- SEC. 91.9606. INFORMATION REQUIRED ON PLANS.
- SEC. 91.9701. TITLE.
- SEC. 91.9702. PURPOSE.
- SEC. 91.9703. SCOPE.
- SEC. 91.9704. DEFINITIONS.
- SEC. 91.9705. BENCHMARKING AND SELF-REPORTING OF ENERGY AND WA…
- SEC. 91.9706. ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING.
- SEC. 91.9707. RECORD MAINTENANCE.
- SEC. 91.9708. SCHEDULE FOR COMPLIANCE.
- SEC. 91.9709. NONCOMPLIANCE FEE.
- SEC. 91.9710. SUBMITTAL FEES.
- SEC. 91.9711. BUILDING AND SAFETY DEVELOPMENT SURCHARGE.
- SEC. 91.9712. SEVERABILITY.
- Article 1.2
- Article 1.5
- Article 7
- Article 8
- Article 9
- Chapter XV
- Chapter XVI