409.4 Limitation of Hot Water Temperature in Bath- tubs and Whirlpool Bathtubs. The maximum hot water temperature discharging from the bathtub and whirlpool bathtub filler shall be limited to 120°F (49°C). The maximum temperature shall be regulated by one of the following means:
«
«
«
«
«
»
»
»
(1) A limiting device conforming to either ASSE 1070/ASME A112.1070/CSA B125.70 or CSA B125.3.
(2) A water heater conforming to ASSE 1084.