Chapter 6 — WATER SUPPLY AND DISTRIBUTION
605.10 PEX-AL-PEX Plastic Tubing and Joints — 2025 California Plumbing Code
California Plumbing Code (Title 24, Part 5) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Plumbing Code (Title 24, Part 5) § 605.10 · Effective January 1, 2026 · Official source: Building Standards Commission
PEXAL-PEX plastic pipe or tubing and fitting joining methods shall be installed in accordance with the manufacturer’s installation instructions and shall comply with Section 605.10.1 and Section 605.10.1.1.
[BSC, DSA-SS, HCD 1 & HCD 2] PEX-AL-PEX is not adopted for use in potable water supply and distribution sys-
tems.
605.10.1 Mechanical Joints. Mechanical joints between PEX-AL-PEX tubing and fittings shall include mechanical and compression type fittings and insert fittings with a crimping ring. Insert fittings utilizing a crimping ring shall comply with ASTM F1974 or ASTM F2434. Crimp joints for crimp insert fittings shall be joined to PEX-AL-PEX pipe by the compression of a crimp ring around the outer circumference of the pipe, forcing the pipe material into annular spaces formed by ribs on the fitting.
[BSC] PEX-AL-PEX is not adopted for use in potable water supply and distribution systems. 605.10.1.1 Compression Joints. Compression joints shall include compression insert fittings and shall be joined to PEX-AL-PEX pipe through the compression of a split ring or compression nut around the outer circumference of the pipe, forcing the pipe material into the annular space formed by the ribs on the fitting.
[BSC] PEX-AL-PEX is not adopted for use in potable water supply and distribution systems.