Skip to content

Chapter IXArticle 1.5

SEC. 93.0700. THE CALIFORNIA ELECTRICAL CODE.

Los Angeles Rent Rules (LAMC excerpts) · 2025 edition · updated 2026-07-25 · Los Angeles

(Amended by Ord. No. 187,719, Eff. 1/23/23.)

Chapters 1 through 9, Annex C, H, G and I of the National Electrical Code (NEC), as published by the National Fire Protection Association (N.F.P.A. 70), the California Electrical Code (CEC) and the California Building Standards Code are adopted by reference as part of the Code. When there is a conflict between the NEC, the CEC and the Los Angeles Municipal Code (LAMC), LAMC Section 93.0105 shall prevail. Except as specified in Divisions 1 through 7 of Article 3, Chapter IX of the LAMC, all electrical installations and materials shall be in conformity with the California Electrical Code, as adopted by reference to be part of this Code; and Subsections 93.0700.19, 93.515.17 and 93.515.18 are added as provided here.

93.0700.19. Illuminated Exit Signs. Illuminated exit signs used as part of emergency system shall be supplied from two independent branch circuits. One branch circuit shall be supplied from an emergency system, and the other branch circuit shall be supplied from a normal system.

EXCEPTION: Unit equipment branch circuits as permitted in CEC Section 700.12 (I).

93.515.17. Oil and Gas Wells. (Amended by Ord. No. 185,587, Eff. 7/16/18.)

(a) This subsection shall be applicable to oil or gas wells located over water, on human-made islands offshore or at land-based locations. Area adjacent to oil or gas wells shall be classified as Class I locations as outlined below, and installations shall comply with the requirement for those locations.

(b) Definitions.

ADEQUATE VENTILATION. (as applied to enclosed areas) A mechanical ventilation system supplied from a nonhazardous source that provides for a minimum of 12 air changes per hour.

ENCLOSED AREA. Roofed areas having at least three walls, or open sumps or pits into which highly volatile liquids are run, or areas surrounded by buildings or walls in which flammable vapors may accumulate.

LOCOMOTIVE CABLE. Cable having the physical property of being oil resistant and constructed as to be suitable for application on power and control circuits in diesel or electric locomotives and suitable for oil rigging applications.

POSITIVE PRESSURE VENTILATION. A mechanical ventilation system capable of providing a minimum outward air velocity of 60 feet per minute through all openings.

(c) Drilling Wells.

  1. Class I, Division I Locations. The following areas shall be classified as Class I, Division I locations:

A. Below-grade well cellars, sumps or ditches. See Figures 2 and 6 of Division 7, Article 3, Chapter IX of the LAMC.

B. Enclosed and inadequately ventilated areas below the derrick floor. See Figure 1 of Division 7, Article 3, Chapter IX of the LAMC.

C. Enclosed areas containing mud tanks or shale shakers. See Figures 3 through 6 of Division 7, Article 3, Chapter IX of the LAMC.

EXCEPTIONS:

  1. Adequately ventilated enclosed areas shall be permitted to be classified as Class I, Division 2 locations.

  2. (Over 600 volts, nominal): Oil or gas well in the process of drilling shall have a Division 2 classification within 25 feet (7.62 m) of the casing, with the 18 inch (457.2 mm) height limitation adjacent to the drilling platform. The entire area directly above and below the drilling platform proper shall be considered as Division 2 without height limitation.

  3. Class I, Division 2 Locations. The following areas shall be classified as Class I, Division 2 locations:

A. Within 10 feet (3048 mm) horizontally and 18 inches (457.2 mm) vertically from the edge of the well cellars or other below grade, Class I, Division I locations.

B. Within 10 feet (3048 mm) radially of the center of the bell nipple in open derricks.

C. The entire area above the derrick floor in enclosed derricks.

D. Areas adjacent to mud tanks as required in Figures 3 and 4; pits as required in Figure 2; shale shakers as required in Figure 5; or openings as required in Figure 2. The figures referenced in this paragraph are located in Division 7, Article 3, Chapter IX of the LAMC.

EXCEPTION: In enclosures classified as Class I, Division I locations in Subsection (c) 1 above.

(d) Producing Wells.

  1. Class I, Division I locations. The following areas shall be classified as Class I, Division I locations:

A. Below-grade well cellars. See Figures 7 and 9 of Division 7, Article 3, Chapter IX of the LAMC.

B. Enclosed areas such as, wellhead, compressor or pump rooms where volatile, flammable liquids or gases may be present in concentrations sufficient to render the area a hazardous location.

NOTE: See Figures 8 through 10 of Division 7, Article 3, Chapter IX of the LAMC.

EXCEPTIONS:

  1. Adequately ventilated enclosed areas shall be permitted to be classified as Class I, Division 2 locations.

NOTE: See Figure 7 of Division 7, Article 3, Chapter IX of the LAMC.

  1. (Over 600 volts, nominal): In case of producing oil wells, the Division 2 classification shall include an area within 3 feet (914.4 mm) of the well casing to a height of 3 feet around the stuffing box or lubricator, and the area extending 10 feet (3048 mm) from the well casing to a height of 18 inches (457.2 mm) above the grade level of all producing oil wells (pumped, flowing or gas injected) having a gas pressure sufficient to cause gas to be liberated to the atmosphere in quantities to create a hazard to employees should liberated gas become ignited. Producing gas wells shall have a similar classified area.

  2. Class I, Division 2 Locations. The following areas shall be classified as Class I, Division 2 locations:

A. Within 10 feet (3048 mm) horizontally and 18 inches (457.2 mm) vertically from the well casing and three feet radially from the stuffing box of all producing wells equipped with beam pumping units.

NOTE: See Figures 8 and 9 of Division 7, Article 3, Chapter IX of the LAMC.

B. Within ten feet horizontally and 18 inches (457.2 mm) vertically above grade from the edge of well cellars or other below grade Class I, Division I locations.

C. Within 10 feet (3048 mm) horizontally and vertically from openings in enclosed areas classified as Class I, Division I locations in Subsection (d) 1 above.

NOTE: See Figures 3, 5 and 10 of Division 7, Article 3, Chapter IX of the LAMC.

  1. Class I, Division 1 and 2. Areas within a 10 foot (3048 mm) radius of oil field auxiliary equipment such as gas vents, oil-gas separator vessels, tanks, pumps, compressors and similar equipment shall be classified in accordance with Figures 11 through 19 of Division 7, Article 3, Chapter IX of the LAMC.

(e) Overload Protection. No overload protection will be required for drilling rigs using railroad locomotive power systems for the draw works, rotary tables and mud pumps.

NOTE: In this electrical system, generators, generator power leads, and DC motors are automatically protected against overload by inherent characteristics of compound and differential field windings in the DC motor and generator, respectively.

(f) Wiring Methods.

  1. General. Where drilling platforms are not enclosed around the drilling operation, all wiring and equipment within 25 feet of the casing of the well being drilled shall be of the type required for Class I, Division 2 locations, or be installed in enclosed areas supplied with adequate ventilation. The electrical power supply to wiring and equipment within positive pressure ventilated areas shall be arranged to prevent energizing the electrical wiring and apparatus until air pressure has been established, for not less than two minutes, and arranged to automatically actuate an audible and visual alarm with a 5-minute shutdown time delay to allow safe operational shutdown prior to de- energizing the wiring and apparatus when the ventilation fails.

Enclosed areas supplied with positive pressure ventilation from a nonhazardous area shall be permitted to be classified as nonhazardous areas, provided no flammable vapor source exists within the enclosed areas.

  1. Locomotive Type Cables. Special locomotive cables and other equivalent portable cables may be run in cable trays under the following conditions in all locations:

A. Open cable trays may be run horizontally under floors or ceilings.

B. In all locations, solid covers shall be installed on horizontal runs where persons or materials may accidentally contact the conductors.

C. Vertical runs of trays shall be totally enclosed.

D. Where the rig moves over a series of well holes and a transverse section of cable tray drops trailing cables in a long fixed runway tray, cleats or other means shall be used to secure the cable against shifting in the moving section of the tray.

E. For single hole setups onshore, cables may be buried in the earth or run in covered, wooden troughs between outdoor units of equipment. A substantial, nominal 2-inch thick wooden cover or equivalent, shall be installed over the trough.

(g) Lighting. Lighting systems for oil or gas well drilling rigs, production hoists, derricks or masts shall be permitted to be wired using an approved prefabricated assembly of flexible cables with vulcanized, molded or other approved terminating receptacle devices so designed that electric arcs will be confined within the receptacle enclosure which shall be the concealed contact-type. The lighting fixture shall be of the type permitted for Class I, Division I locations, or of the enclosed gasketed-type. These assemblies shall be securely fastened to the drilling rig or hoist structure and so located that they will be protected from physical damage.

(Figures 1 - 19 Inclusive, Relocated from Division 11 by Ord. No. 172,593, Eff. 6/28/99, Oper. 7/1/99.) [https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-137.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-140.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-143.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-146.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-149.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-152.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-155.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-158.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-161.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-164.gif]

[https://export.amlegal.com/media/9fc1cbc9c3e12e95c80c2e8b69dc90857ba2cf19/ IMAGES/0-0-0-167.gif]

93.515.18. Bulk-storage Plants – Tanker Loading Docks. (Amended by Ord. No. 185,587, Eff. 7/16/18.)

(a) Scope. The provisions of this section shall apply in addition to the requirements of Article 515 of the CEC.

(b) Definitions. (Amended by Ord. No. 179,325, Eff. 12/10/07, Oper. 1/1/ 08.)

BULK STORAGE PLANT or TANKER LOADING DOCK DESIGNATIONS. The bulk storage plant and tanker loading dock designation shall also include locations where ships carrying bulk cargoes of gasoline or other volatile flammable liquids are loaded or unloaded.

WATER LEVEL. The water level shall be the measured mean value of the high tide lines.

(c) Loading and Unloading Tanker Ships. (Amended by Ord. No. 179,325, Eff. 12/10/07, Oper. 1/1/08.)

  1. The interior of a building, any portion of which is located in a Class I, Division 2 location, shall be classified as a Class I, Division 2 location.

EXCEPTION: Buildings that are provided with satisfactory positive pressure ventilation, and safeguards, with air taken from a clean air source may be considered to be a nonhazardous location.

  1. All electrical power drive pumps and transfer apparatus for flammable liquids shall be provided with an identified “stop” or normal control switch within sight and readily accessible to the person operating the equipment.

(d) Existing Tanker Loading Dock Installations. All existing electrical installations at tanker loading docks shall comply with the provisions of this section and Article 515 of the CEC.

ARTICLE 4

PLUMBING CODE

Get a plain-English answer with a citation back to this text.

Ask AI about this code
Contents — Los Angeles Rent Rules (LAMC excerpts)
Los Angeles Rent Rules (LAMC excerpts)
  1. Chapter I
  2. Chapter IX
    Overview
    1. SEC. 91.101. TITLE, PURPOSE, AND SCOPE.
    2. SEC. 91.102. UNSAFE BUILDINGS OR STRUCTURES.
    3. SEC. 91.103. VIOLATIONS.
    4. SEC. 91.104. ORGANIZATION AND ENFORCEMENT.
    5. SEC. 91.105. APPEALS.
    6. SEC. 91.106. PERMITS.
    7. SEC. 91.107. FEES.
    8. SEC. 91.108. INSPECTION.
    9. SEC. 91.109. CERTIFICATE OF OCCUPANCY.
    10. SEC. 91.110. RESPONSIBILITY OF PERMITTEE.
    11. SEC. 91.111. CODE REVISION.
    12. SEC. 91.113. PERMIT FEES.
    13. SEC. 91.201. GENERAL.
    14. SEC. 91.202. DEFINITIONS.
    15. SEC. 91.300. BASIC PROVISIONS.
    16. SEC. 91.400. BASIC PROVISIONS.
    17. SEC. 91.500. BASIC PROVISIONS.
    18. SEC. 91.600. BASIC PROVISIONS.
    19. SEC. 91.700. BASIC PROVISIONS.
    20. SEC. 91.703. FIRE-RESISTANCE RATINGS AND FIRE TESTS.
    21. SEC. 91.800. BASIC PROVISIONS.
    22. SEC. 91.900. BASIC PROVISIONS.
    23. SEC. 91.909. SMOKE CONTROL SYSTEMS.
    24. SEC. 91.1000. BASIC PROVISIONS.
    25. SEC. 91.1100. BASIC PROVISIONS.
    26. SEC. 91.1200. BASIC PROVISIONS.
    27. SEC. 91.1206. SOUND TRANSMISSION.
    28. SEC. 91.1300. GENERAL.
    29. SEC. 91.1301. SOLAR ENERGY COLLECTORS.
    30. SEC. 91.1400. BASIC PROVISIONS.
    31. SEC. 91.1402. PERFORMANCE REQUIREMENTS.
    32. SEC. 91.1500. BASIC PROVISIONS.
    33. SEC. 91.1505. FIRE CLASSIFICATION.
    34. SEC. 91.1507. REQUIREMENTS FOR ROOF COVERINGS.
    35. SEC. 91.1511. REROOFING.
    36. SEC. 91.1600. BASIC PROVISIONS.
    37. SEC. 91.1603. CONSTRUCTION DOCUMENTS.
    38. SEC. 91.1609. WIND LOADS.
    39. SEC. 91.1612. FLOOD LOADS.
    40. SEC. 91.1613. EARTHQUAKE LOADS.
    41. SEC. 91.1700. GENERAL.
    42. SEC. 91.1702. NEW MATERIALS.
    43. SEC. 91.1703. APPROVALS.
    44. SEC. 91.1704. SPECIAL INSPECTIONS.
    45. SEC. 91.1705. REQUIRED VERIFICATION AND INSPECTION.
    46. SEC. 91.1706. DESIGN STRENGTHS OF MATERIALS.
    47. SEC. 91.1710. CERTIFIED SECURITY BAR INSTALLER.
    48. SEC. 91.1711. PREFABRICATED CONSTRUCTION.
    49. SEC. 91.1800. BASIC PROVISIONS.
    50. SEC. 91.1801. GENERAL.
    51. SEC. 91.1802. DESIGN BASIS.
    52. SEC. 91.1803. GEOTECHNICAL INVESTIGATION.
    53. SEC. 91.1804. EXCAVATION, GRADING AND FILL.
    54. SEC. 91.1805. DAMPPROOFING AND WATERPROOFING.
    55. SEC. 91.1806. PRESUMPTIVE LOAD BEARING VALUES OF SOILS.
    56. SEC. 91.1807. FOUNDATION WALLS, RETAINING WALLS, AND EMBEDDED …
    57. SEC. 91.1808. FOUNDATIONS.
    58. SEC. 91.1809. SHALLOW FOUNDATIONS.
    59. SEC. 91.1810. DEEP FOUNDATIONS..
    60. SEC. 91.1900. BASIC PROVISIONS.
    61. SEC. 91.2000. BASIC PROVISIONS.
    62. SEC. 91.2100. BASIC PROVISIONS.
    63. SEC. 91.2113. MASONRY CHIMNEYS.
    64. SEC. 91.2200. BASIC PROVISIONS.
    65. SEC. 91.2204. CONNECTIONS.
    66. SEC. 91.2300. BASIC PROVISIONS.
    67. SEC. 91.2301. GENERAL.
    68. SEC. 91.2304. GENERAL CONSTRUCTION REQUIREMENTS.
    69. SEC. 91.2305. GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RE…
    70. SEC. 91.2306. ALLOWABLE STRESS DESIGN.
    71. SEC. 91.2308. CONVENTIONAL LIGHT-FRAME CONSTRUCTION.
    72. SEC. 91.2400. BASIC PROVISIONS.
    73. SEC. 91.2503. INSPECTIONS.
    74. SEC. 91.2600. BASIC PROVISIONS.
    75. SEC. 91.2700. BASIC PROVISIONS.
    76. SEC. 91.2800. BASIC PROVISIONS.
    77. SEC. 91.2900. BASIC PROVISIONS.
    78. SEC. 91.3000. BASIC PROVISIONS.
    79. SEC. 91.3001. GENERAL.
    80. SEC. 91.3002. HOISTWAY ENCLOSURES.
    81. SEC. 91.3003. EMERGENCY OPERATIONS.
    82. SEC. 91.3004. CONVEYING SYSTEMS.
    83. SEC. 91.3005. CONVEYING SYSTEMS.
    84. SEC. 91.3007. FIRE SERVICE ACCESS ELEVATOR.
    85. SEC. 91.3008. OCCUPANT EVACUATION ELEVATORS.
    86. SEC. 91.3100. BASIC PROVISIONS.
    87. SEC. 91.3106. MARQUEES.
    88. SEC. 91.3108. TELECOMMUNICATIONS AND BROADCAST TOWERS.
    89. SEC. 91.3109. SWIMMING POOL ENCLOSURES AND SAFETY DEVICES.
    90. SEC. 91.3112. PATIO COVERS.
    91. SEC. 91.3200. BASIC PROVISIONS.
    92. SEC. 91.3201. GENERAL.
    93. SEC. 91.3202. GENERAL.
    94. SEC. 91.3300. BASIC PROVISIONS.
    95. SEC. 91.3301. GENERAL.
    96. SEC. 91.3304. SITE WORK.
    97. SEC. 91.3305. TOILET FACILITIES DURING CONSTRUCTION.
    98. SEC. 91.3306. PROTECTION OF PEDESTRIANS.
    99. SEC. 91.3307. PROTECTION OF ADJOINING PROPERTY.
    100. SEC. 91.3500. BASIC PROVISIONS.
    101. SEC. 91.6101. IMPACT HAZARD GLAZING IN EXISTING BUILDINGS.
    102. SEC. 91.6102. RUBBISH ROOMS.
    103. SEC. 91.6103. SHAFTS, PITS AND SIMILAR EXCAVATION – MISDEMEANOR.
    104. SEC. 91.6104. FIRE DISTRICTS.
    105. SEC. 91.6105. SEPARATION FROM OIL WELLS.
    106. SEC. 91.6107. TRANSFORMER VAULTS.
    107. SEC. 91.6109. SWIMMING POOLS AND OTHER BODIES OF WATER – PROTE…
    108. SEC. 91.6201. GENERAL PROVISIONS.
    109. SEC. 91.6202. DEFINITIONS.
    110. SEC. 91.6203. LOCATION.
    111. SEC. 91.6204. IDENTIFICATION.
    112. SEC. 91.6205. DESIGN AND CONSTRUCTION.
    113. SEC. 91.6206. ELECTRICAL.
    114. SEC. 91.6207. COMBUSTIBLE MATERIALS.
    115. SEC. 91.6208. ANIMATED DEVICES.
    116. SEC. 91.6209. GROUND SIGNS.
    117. SEC. 91.6210. ROOF SIGNS.
    118. SEC. 91.6211. WALL SIGNS.
    119. SEC. 91.6212. PROJECTING SIGNS.
    120. SEC. 91.6213. MARQUEE SIGNS.
    121. SEC. 91.6214. PORTABLE SIGNS.
    122. SEC. 91.6215. REFERENCED STANDARDS.
    123. SEC. 91.6216. EXISTING SIGNS.
    124. SEC. 91.6301. GENERAL.
    125. SEC. 91.6302. FOOD ESTABLISHMENT.
    126. SEC. 91.6303. SERVICE STATIONS.
    127. SEC. 91.6304. RESIDENTIAL USES.
    128. SEC. 91.6305. PARKING GARAGES SERVING RESIDENTIAL USES.
    129. SEC. 91.6306. ANTI-GRAFFITI FINISH TO EXTERIOR WALLS.
    130. SEC. 91.6307. SHOWER AND LOCKER FACILITIES.
    131. SEC. 91.6701. PURPOSE.
    132. SEC. 91.6702. GENERAL.
    133. SEC. 91.6703. LIMITATIONS.
    134. SEC. 91.6704. ALTERNATE SECURITY PROVISIONS.
    135. SEC. 91.6705. DEFINITIONS.
    136. SEC. 91.6706. ENTRY VISION.
    137. SEC. 91.6707. APPURTENANT ACCESS.
    138. SEC. 91.6708. DOORS – GENERAL.
    139. SEC. 91.6709. SWINGING DOORS.
    140. SEC. 91.6710. SLIDING GLASS DOORS.
    141. SEC. 91.6711. OVERHEAD AND SLIDING DOORS.
    142. SEC. 91.6712. METAL ACCORDION-GRATE OR GRILLE-TYPE DOORS.
    143. SEC. 91.6713. GLAZED OPENING – GENERAL.
    144. SEC. 91.6714. GLAZING.
    145. SEC. 91.6715. WINDOWS.
    146. SEC. 91.6716. OPENINGS OTHER THAN DOORS OR GLAZED OPENINGS.
    147. SEC. 91.6717. TESTS – GENERAL.
    148. SEC. 91.7001. PURPOSE.
    149. SEC. 91.7002. SCOPE.
    150. SEC. 91.7003. DEFINITIONS.
    151. SEC. 91.7004. GRADING DESIGNATION.
    152. SEC. 91.7005. GENERAL REQUIREMENTS.
    153. SEC. 91.7006. CONDITIONS PRECEDENT TO ISSUING A GRADING PERMIT.
    154. SEC. 91.7007. SAFETY PRECAUTIONS DURING GRADING.
    155. SEC. 91.7008. PROFESSIONAL INSPECTION AND CERTIFICATION FOR EN…
    156. SEC. 91.7009. PROFESSIONAL INSPECTION FOR REGULAR GRADING.
    157. SEC. 91.7010. EXCAVATIONS.
    158. SEC. 91.7011. FILLS.
    159. SEC. 91.7012. PLANTING AND IRRIGATION OF CUT AND FILL SLOPES I…
    160. SEC. 91.7013. EROSION CONTROL AND DRAINAGE DEVICES.
    161. SEC. 91.7014. CONSTRUCTION REQUIREMENTS AND LIMITATIONS.
    162. SEC. 91.7015. BUTTRESS FILLS.
    163. SEC. 91.7016. AREAS SUBJECTED TO SLIDES AND UNSTABLE SOIL.
    164. SEC. 91.7101. PURPOSE.
    165. SEC. 91.7102. DEFINITIONS.
    166. SEC. 91.7103. GENERAL METHANE MITIGATION REQUIREMENTS.
    167. SEC. 91.7104. GENERAL METHANE REQUIREMENTS.
    168. SEC. 91.7105. EXISTING BUILDINGS.
    169. SEC. 91.7106. TESTING, MAINTENANCE AND SERVICE OF GAS-DETECTIO…
    170. SEC. 91.7107. EMERGENCY PROCEDURES.
    171. SEC. 91.7108. APPLICATION OF METHANE SEEPAGE REGULATIONS TO LO…
    172. SEC. 91.7109. ADDITIONAL REMEDIAL MEASURES.
    173. SEC. 91.7200. PURPOSE.
    174. SEC. 91.7201. GENERAL.
    175. SEC. 91.7202. ADDITIONS TO BUILDINGS.
    176. SEC. 91.7203. GENERAL REQUIREMENTS.
    177. SEC. 91.7204. SPECIAL REQUIREMENTS FOR FIRE DISTRICT NUMBER 1.
    178. SEC. 91.7205. PROVISIONAL STRUCTURES.
    179. SEC. 91.7207. SPECIAL REQUIREMENTS FOR THE VERY HIGH FIRE HAZA…
    180. SEC. 91.7208. PROHIBITED VEHICLES.
    181. SEC. 91.8101. GENERAL PROVISIONS.
    182. SEC. 91.8102. ENFORCEMENT.
    183. SEC. 91.8103. EXISTING BUILDING RIGHTS.
    184. SEC. 91.8104. BASIC MAINTENANCE AND REPAIR OF EXISTING BUILDIN…
    185. SEC. 91.8105. ILLEGAL BUILDINGS, CONSTRUCTION AND USE.
    186. SEC. 91.8106. FIRE DISTRICT REQUIREMENTS.
    187. SEC. 91.8108. NUISANCES, HAZARDOUS BUILDINGS AND SUBSTANDARD R…
    188. SEC. 91.8109. RELOCATED BUILDINGS.
    189. SEC. 91.8110. UNREINFORCED MASONRY BEARING WALL BUILDINGS.
    190. SEC. 91.8111. RESIDENTIAL HEATING.
    191. SEC. 91.8112. RESIDENTIAL PLUMBING.
    192. SEC. 91.8113. ROD BRACING SYSTEMS.
    193. SEC. 91.8114. PARAPETS AND APPENDAGES.
    194. SEC. 91.8115. SANDBLASTING.
    195. SEC. 91.8116. SPECIAL PROVISIONS FOR LIGHT-HOUSEKEEPING ROOMS.
    196. SEC. 91.8117. FIRE WATCH.
    197. SEC. 91.8118. POOL WATER CLARITY.
    198. SEC. 91.8119. HISTORICAL BUILDINGS AND STRUCTURES.
    199. SEC. 91.8201. GENERAL.
    200. SEC. 91.8202. CHANGE OF RATING CLASSIFICATION.
    201. SEC. 91.8203. CHANGE OF OCCUPANCY GROUP OR GROUP DIVISION.
    202. SEC. 91.8204. CHANGE OF USE.
    203. SEC. 91.8205. CERTIFICATE OF BUILDING COMPLIANCE.
    204. SEC. 91.8301. GENERAL APPLICATION.
    205. SEC. 91.8302. PERMITS REQUIRED – GENERAL CONSIDERATIONS.
    206. SEC. 91.8303. PERMIT APPLICATION – PLANS AND SPECIFICATIONS.
    207. SEC. 91.8304. SPECIAL CONDITIONS UNDER WHICH A PERMIT WILL NOT…
    208. SEC. 91.8305. GUARANTEE OF COMPLETION REQUIRED.
    209. SEC. 91.8306. TERMS OF PERMIT.
    210. SEC. 91.8307. DEFAULT IN PERFORMANCE OF CONDITIONS OR TERMS OF…
    211. SEC. 91.8308. PERMIT FEES.
    212. SEC. 91.8309. ENTRY UPON PREMISES.
    213. SEC. 91.8501. GENERAL.
    214. SEC. 91.8502. ALTERNATIVE STANDARDS.
    215. SEC. 91.8601. GENERAL.
    216. SEC. 91.8602. GROUP E OCCUPANCIES.
    217. SEC. 91.8603. FIRE PROTECTION – WARNING SYSTEM.
    218. SEC. 91.8604. FIRE SAFETY STANDARDS.
    219. SEC. 91.8605. EMERGENCY HOMELESS SHELTERS.
    220. SEC. 91.8606. EMERGENCY LIGHTING STANDARDS FOR EXISTING RESIDE…
    221. SEC. 91.8607. TENANT SAFETY FOR APARTMENT HOUSES, EXCEPT FOR R…
    222. SEC. 91.8801. PURPOSE.
    223. SEC. 91.8802. SCOPE.
    224. SEC. 91.8803. DEFINITIONS.
    225. SEC. 91.8804. RATING CLASSIFICATIONS.
    226. SEC. 91.8805. GENERAL REQUIREMENTS.
    227. SEC. 91.8806. ADMINISTRATION.
    228. SEC. 91.8807. HISTORICAL BUILDINGS.
    229. SEC. 91.8808. ANALYSIS AND DESIGN.
    230. SEC. 91.8809. MATERIALS OF CONSTRUCTION.
    231. SEC. 91.8810. INFORMATION REQUIRED ON PLANS.
    232. SEC. 91.8811. DESIGN CHECK – COMPATIBILITY OF ROOF DIAPHRAGM S…
    233. SEC. 91.8812. VIOLATIONS.
    234. SEC. 91.8813. SPECIAL REQUIREMENTS FOR VACANT BUILDINGS.
    235. SEC. 91.8901. GENERAL.
    236. SEC. 91.8902. DEFINITIONS.
    237. SEC. 91.8903. ABATEMENT PROCEDURES.
    238. SEC. 91.8903 Los Angeles Municipal Code.
    239. SEC. 91.8904. SPECIAL PROVISIONS FOR VACANT PROPERTY GRAFFITI …
    240. SEC. 91.8905. SPECIAL PROVISIONS FOR VACATING, BARRICADING, RE…
    241. SEC. 91.8906. PAYMENT AND RECOVERY OF REPAIR AND DEMOLITION FU…
    242. SEC. 91.8907. ABATEMENT OF PUBLIC NUISANCE CONDITIONS RELATED …
    243. SEC. 91.8908. SPECIAL PROVISIONS FOR THE REPAIR OF WELDED STEE…
    244. SEC. 91.8910. PROCEDURE FOR ABATEMENT OF NUISANCE; RECOVERY OF…
    245. SEC. 91.9001. GENERAL.
    246. SEC. 91.9002. DEFINITIONS.
    247. SEC. 91.9003. ABATEMENT PROCEDURES.
    248. SEC. 91.9101. PURPOSE.
    249. SEC. 91.9102. SCOPE.
    250. SEC. 91.9103. DEFINITIONS.
    251. SEC. 91.9104. RATING CLASSIFICATIONS.
    252. SEC. 91.9105. GENERAL REQUIREMENTS.
    253. SEC. 91.9106. ADMINISTRATION.
    254. SEC. 91.9107. HISTORICAL BUILDINGS.
    255. SEC. 91.9108. ANALYSIS AND DESIGN.
    256. SEC. 91.9109. MATERIALS OF CONSTRUCTION.
    257. SEC. 91.9110. INFORMATION REQUIRED ON PLANS.
    258. SEC. 91.9111. REQUIRED BUILDING MAINTENANCE.
    259. SEC. 91.9112. VIOLATIONS – PENALTIES FOR DISREGARDING DEPARTME…
    260. SEC. 91.9201. GENERAL.
    261. SEC. 91.9202. DEFINITIONS.
    262. SEC. 91.9203. STRUCTURAL WEAKNESSES.
    263. SEC. 91.9204. STRENGTHENING REQUIREMENTS.
    264. SEC. 91.9205. QUALITY CONTROL.
    265. SEC. 91.9301. PURPOSE.
    266. SEC. 91.9302. SCOPE.
    267. SEC. 91.9303. DEFINITIONS.
    268. SEC. 91.9304. PRIORITY DESIGNATIONS.
    269. SEC. 91.9305. COMPLIANCE REQUIREMENTS.
    270. SEC. 91.9306. ADMINISTRATION.
    271. SEC. 91.9307. OCCUPANT AND TENANT ADVISORY.
    272. SEC. 91.9308. HISTORICAL BULDINGS.
    273. SEC. 91.9309. ENGINEERING ANALYSIS.
    274. SEC. 91.9310. INFORMATION REQUIRED ON PLANS.
    275. SEC. 91.9311. VIOLATION / PENALTY.
    276. SEC. 91.9312. SEVERABILITY.
    277. SEC. 91.9401. PURPOSE.
    278. SEC. 91.9402. SCOPE.
    279. SEC. 91.9403. DEFINITIONS.
    280. SEC. 91.9404. GENERAL REQUIREMENTS.
    281. SEC. 91.9405. PRE-DESIGN INVESTIGATION.
    282. SEC. 91.9406. ANALYSIS AND DESIGN.
    283. SEC. 91.9407. HISTORICAL BUILDINGS.
    284. SEC. 91.9408. QUALITY CONTROL.
    285. SEC. 91.9409. INFORMATION REQUIRED ON PLANS.
    286. SEC. 91.9501. PURPOSE.
    287. SEC. 91.9502. SCOPE.
    288. SEC. 91.9503. DEFINITIONS.
    289. SEC. 91.9504. COMPLIANCE REQUIREMENTS.
    290. SEC. 91.9505. ADMINISTRATION.
    291. SEC. 91.9506. OCCUPANT AND TENANT ADVISORY.
    292. SEC. 91.9507. HISTORICAL BUILDINGS.
    293. SEC. 91.9508. ENGINEERING ANALYSIS.
    294. SEC. 91.9509. INFORMATION REQUIRED ON PLANS.
    295. SEC. 91.9510. VIOLATION / PENALTY.
    296. SEC. 91.9511. SEVERABILITY.
    297. SEC. 91.9601. PURPOSE.
    298. SEC. 91.9602. SCOPE.
    299. SEC. 91.9603. DEFINITIONS.
    300. SEC. 91.9604. ANALYSIS AND DESIGN.
    301. SEC. 91.9605. MATERIALS OF CONSTRUCTION.
    302. SEC. 91.9606. INFORMATION REQUIRED ON PLANS.
    303. SEC. 91.9701. TITLE.
    304. SEC. 91.9702. PURPOSE.
    305. SEC. 91.9703. SCOPE.
    306. SEC. 91.9704. DEFINITIONS.
    307. SEC. 91.9705. BENCHMARKING AND SELF-REPORTING OF ENERGY AND WA…
    308. SEC. 91.9706. ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING.
    309. SEC. 91.9707. RECORD MAINTENANCE.
    310. SEC. 91.9708. SCHEDULE FOR COMPLIANCE.
    311. SEC. 91.9709. NONCOMPLIANCE FEE.
    312. SEC. 91.9710. SUBMITTAL FEES.
    313. SEC. 91.9711. BUILDING AND SAFETY DEVELOPMENT SURCHARGE.
    314. SEC. 91.9712. SEVERABILITY.
    315. Article 1.2
    316. Article 1.5
      Overview
      1. § 91.5
      2. SEC. 92.0101. TITLE.
      3. SEC. 92.0102. PURPOSE.
      4. SEC. 92.0103. SCOPE.
      5. SEC. 92.0104. INTERPRETATION.
      6. SEC. 92.0105. REPORTS OF ELEVATOR SAFETY ENGINEERS.
      7. SEC. 92.0106. EQUIPMENT FOUND UNSAFE.
      8. SEC. 92.0107. POWER TO SEAL EQUIPMENT OUT OF SERVICE AND STOP …
      9. SEC. 92.0108. RESERVED.
      10. SEC. 92.0109. REQUIRED ELEVATORS.
      11. SEC. 92.0110. TEST OF NEW EQUIPMENT.
      12. SEC. 92.0111. APPROVAL OF PLANS AND EQUIPMENT.
      13. SEC. 92.0112. RETROACTIVE PROVISIONS.
      14. SEC. 92.0113. AUTHORITY TO ENTER BUILDING OR PREMISE.
      15. SEC. 92.0114. CERTIFICATE OF INSPECTION (OPERATING PERMIT).
      16. SEC. 92.0115. REQUEST FOR INSPECTION.
      17. SEC. 92.0116. ACCIDENTS – REPORTS – REPAIR.
      18. SEC. 92.0117. ENFORCEMENT.
      19. SEC. 92.0118. CERTIFICATE OF REGISTRATION.
      20. SEC. 92.0119. JOURNEY-LEVEL ELEVATOR MECHANIC – CERTIFICATE RE…
      21. SEC. 92.0120. APPLICATION FOR JOURNEY-LEVEL ELEVATOR MECHANIC.
      22. SEC. 92.0121. HELPERS OR APPRENTICES.
      23. SEC. 92.0122. EXPIRATION OF CERTIFICATE.
      24. SEC. 92.0123. RENEWAL CERTIFICATE FEES.
      25. SEC. 92.0126. INSPECTION AND INSPECTION FEES.
      26. SEC. 92.0127. SPECIAL ENFORCEMENT OF PROCEDURES FEES.
      27. SEC. 92.0128. INVESTIGATION FEE.
      28. SEC. 92.0129. INSTALLATION PERMIT FEES.
      29. SEC. 92.0130. FEES FOR PLAN CHECKING.
      30. SEC. 92.0131. OFF HOURS INSPECTIONS.
      31. SEC. 92.0132. PERMIT FEES FOR REPAIR, REPLACEMENT, ALTERATION,…
      32. SEC. 92.0133. APPROVALS.
      33. SEC. 92.0134. RESPONSIBILITY OF OWNERS, LESSEES, MANAGERS, ETC.
      34. SEC. 92.0135. POWERS OF DEPARTMENT AND BOARD.
      35. SEC. 92.0136. APPEALS.
      36. SEC. 92.0137. EXPIRATION OF PERMIT AND PLAN CHECK.
      37. SEC. 92.0138. SCOPE OF PERMITS.
      38. SEC. 92.0139. NON-RESPONSIBILITY OF CITY.
      39. SEC. 92.0140. PROCEDURE FOR REVOCATION OR SUSPENSION.
      40. SEC. 92.0141. ALTERNATE MATERIALS AND METHODS OF CONSTRUCTION.
      41. SEC. 92.0201. RESERVED.
      42. SEC. 92.0202. GENERAL.
      43. SEC. 92.0203. SECTIONS NOT ADOPTED FROM THE CALIFORNIA CODE OF…
      44. SEC. 92.0204. RESERVED.
      45. SEC. 92.0205. RETROACTIVE PROVISIONS.
      46. SEC. 92.0206. MECHANICAL LOCKS AND ELECTRIC CONTACTS.
      47. SEC. 92.0207. ADDITIONAL REQUIREMENTS.
      48. SEC. 92.0301. SCOPE.
      49. SEC. 92.0302. PRIVATE RESIDENCE INCLINED ELEVATORS.
      50. SEC. 92.0303. PRIVATE RESIDENCE VERTICAL PLATFORM LIFTS.
      51. SEC. 92.0304. PRIVATE RESIDENCE ELEVATORS.
      52. SEC. 92.0305. CAR ENCLOSURE.
      53. SEC. 92.0306. MACHINE AND CONTROLS.
      54. SEC. 92.0307. CAR DOORS AND GATES.
      55. SEC. 92.0312. NAMEPLATE.
      56. SEC. 92.0313. MAINTENANCE.
      57. SEC. 92.0401. SCOPE.
      58. SEC. 92.0402. GENERAL.
      59. SEC. 93.0101. TITLE.
      60. SEC. 93.0102. PURPOSE.
      61. SEC. 93.0103. SCOPE.
      62. SEC. 93.0104. PROHIBITED ACTS.
      63. SEC. 93.0105. INTERPRETATION.
      64. SEC. 93.0106. OTHER LIMITATIONS.
      65. SEC. 93.0107. DISTRACTING, CONFUSING OR NUISANCE LIGHTING VIEW…
      66. SEC. 93.0108. EXEMPTED FROM CODE.
      67. SEC. 93.0109. EXISTING CONSTRUCTION.
      68. SEC. 93.0110. RELOCATED BUILDINGS.
      69. SEC. 93.0111. CHANGE OF OCCUPANCIES.
      70. SEC. 93.0112. EFFECTIVE DATE.
      71. SEC. 93.0113. REFERRED DOCUMENTS – COPIES.
      72. SEC. 93.0114. RIGHT OF ENTRY.
      73. SEC. 93.0115. CODE ARRANGEMENT.
      74. SEC. 93.0116. FIRE DAMAGED WIRING SYSTEM.
      75. SEC. 93.0117. OUTDOOR LIGHTING AFFECTING RESIDENTIAL PROPERTY.
      76. SEC. 93.0201. PERMIT REQUIRED.
      77. SEC. 93.0202. EXCEPTIONS, PERMITS NOT REQUIRED.
      78. SEC. 93.0203. SCOPE OF PERMIT.
      79. SEC. 93.0204. PERMIT APPLICATIONS.
      80. SEC. 93.0206. PLANS AND SPECIFICATIONS.
      81. SEC. 93.0207. INFORMATION REQUIRED ON PLANS OR SPECIFICATIONS.
      82. SEC. 93.0208. TRANSFER OF PERMITS AND PLAN CHECKS.
      83. SEC. 93.0209. REVOCATION OF PERMITS.
      84. SEC. 93.0210. SEPARATE PERMITS REQUIRED.
      85. SEC. 93.0211. EXPIRATION OF PERMITS.
      86. SEC. 93.0212. INVESTIGATION FEE.
      87. SEC. 93.0213. FEES REQUIRED.
      88. SEC. 93.0214. FEES FOR NEW GENERAL USE BRANCH CIRCUITS.
      89. SEC. 93.0215. FEES FOR ADDING LIGHTING FIXTURES, AND OTHER LOA…
      90. SEC. 93.0216. FEES FOR MOTORS, TRANSFORMERS, HEATING APPLIANCE…
      91. SEC. 93.0217. FEES FOR FIRE ALARM AND SIGNALING SYSTEM, COMMUN…
      92. SEC. 93.0218. FEES FOR SERVICES AND SWITCHBOARD SECTIONS.
      93. SEC. 93.0219. FEES FOR BUSWAYS, POWER DUCT, TROLLEY DUCT, CABL…
      94. SEC. 93.0220. MINIMUM INSPECTION FEE.
      95. SEC. 93.0222. FEES FOR GAS TUBE LIGHTING, SIGNS AND SIGN FLASH…
      96. SEC. 93.0223. FEES FOR SWIMMING POOLS.
      97. SEC. 93.0224. FEE FOR MISCELLANEOUS PERMIT
      98. SEC. 93.0227. FEES FOR CHANGING ADDRESS.
      99. SEC. 93.0228. FEES FOR MOVED BUILDINGS AND STRUCTURES.
      100. SEC. 93.0229. FEES FOR ADDITIONAL INSPECTIONS.
      101. SEC. 93.0230. SPECIAL INSPECTIONS.
      102. SEC. 93.0233. FEES FOR PLAN CHECKING.
      103. SEC. 93.0235. FEES FOR WITNESSING TESTS OF EMERGENCY SYSTEMS A…
      104. SEC. 93.0240. FEES FOR REGISTRATION OF PREMISES COVERED BY A M…
      105. SEC. 93.0242. FEES FOR CERTIFICATE OF QUALIFICATIONS.
      106. SEC. 93.0243. INSPECTION FEES FOR OFF-SITE INSPECTIONS.
      107. SEC. 93.0301. POWERS OF DEPARTMENT AND BOARD.
      108. SEC. 93.0302. APPEALS.
      109. SEC. 93.0303. NEW MATERIALS AND METHODS OF CONSTRUCTION.
      110. SEC. 93.0304. INSPECTIONS.
      111. SEC. 93.0305. REQUEST FOR INSPECTION.
      112. SEC. 93.0306. INSPECTION OF ELECTRICAL WIRING AND EQUIPMENT IN…
      113. SEC. 93.0307. REINSPECTION OF ELECTRIC WIRING.
      114. SEC. 93.0308. TEMPORARY USE OF CURRENT.
      115. SEC. 93.0310. POWER TO STOP WORK.
      116. SEC. 93.0311. AUTHORITY TO CONDEMN INSTALLATIONS.
      117. SEC. 93.0312. ABANDONED WIRING.
      118. SEC. 93.0313. WIRING STANDARDS.
      119. SEC. 93.0314. RESPONSIBILITY FOR COMPLIANCE.
      120. SEC. 93.0315. NON-RESPONSIBILITY OF CITY.
      121. SEC. 93.0401. POWER TO REGULATE.
      122. SEC. 93.0402. ELECTRICAL EQUIPMENT.
      123. SEC. 93.0403. USED EQUIPMENT.
      124. SEC. 93.0501. QUALIFIED INSTALLER.
      125. SEC. 93.0502. CERTIFICATE OF REGISTRATION.
      126. SEC. 93.0503. MAINTENANCE CERTIFICATE OF REGISTRATION.
      127. SEC. 93.0505. CERTIFICATE OF QUALIFICATION.
      128. SEC. 93.0600. BASIC PROVISIONS.
      129. SEC. 93.0700. THE CALIFORNIA ELECTRICAL CODE.
      130. § 94.100
      131. § 94.101
      132. § 94.102
      133. § 94.103
      134. § 94.200
      135. § 94.201
      136. § 94.202
      137. § 94.203
      138. § 94.204
      139. § 94.205
      140. § 94.206
      141. § 94.207
      142. § 94.208
      143. § 94.209
      144. § 94.210
      145. § 94.211
      146. § 94.212
      147. § 94.213
      148. § 94.214
      149. § 94.215
      150. § 94.216
      151. § 94.217
      152. § 94.218
      153. § 94.219
      154. § 94.220
      155. § 94.221
      156. § 94.222
      157. § 94.223
      158. § 94.224
      159. § 94.225
      160. § 94.226
      161. § 94.227
      162. § 94.228
      163. § 94.300
      164. § 94.400
      165. § 94.500
      166. § 94.600
      167. § 94.700
      168. § 94.800
      169. § 94.900
      170. § 94.1000
      171. § 94.1100
      172. § 94.1200
      173. § 94.1217
      174. § 94.1300
      175. § 94.1400
      176. § 94.1500
      177. § 94.1600
      178. § 94.1700
      179. § 94.1800
      180. § 94.1900
      181. § 94.2000
      182. § 94.2001
      183. § 94.2005
      184. § 94.2006
      185. § 94.2010
      186. § 94.2013
      187. § 94.2014
      188. § 94.2020
      189. § 94.2030
      190. § 94.2040
      191. § 94.2050
      192. § 94.2100
      193. SEC. 95.100. BASIC PROVISIONS.
      194. SEC. 95.101. TITLE, SCOPE, AND GENERAL.
      195. SEC. 95.102. APPLICATION TO EXISTING MECHANICAL SYSTEMS.
      196. SEC. 95.103. ALTERNATE MATERIALS AND METHODS OF CONSTRUCTION E…
      197. SEC. 95.104. MODIFICATIONS.
      198. SEC. 95.105. TESTING.
      199. SEC. 95.106. POWERS AND DUTIES OF THE DEPARTMENT.
      200. SEC. 95.107. UNSAFE EQUIPMENT.
      201. SEC. 95.108. APPEALS.
      202. SEC. 95.109. PROHIBITED ACTS.
      203. SEC. 95.111. PERMITS.
      204. SEC. 95.112. APPLICATION FOR PERMIT.
      205. SEC. 95.113. PERMIT ISSUANCE.
      206. SEC. 95.114. PERMIT FEES.
      207. SEC. 95.115. INSPECTIONS.
      208. SEC. 95.116. CONNECTION APPROVAL.
      209. SEC. 95.117. UNCONSTITUTIONAL.
      210. SEC. 95.118. VALIDITY.
      211. SEC. 95.119. REGISTRATION.
      212. § 95.200
      213. § 95.201
      214. § 95.202
      215. § 95.203
      216. § 95.204
      217. § 95.205
      218. § 95.206
      219. § 95.207
      220. § 95.208
      221. § 95.209
      222. § 95.210
      223. § 95.211
      224. § 95.212
      225. § 95.213
      226. § 95.214
      227. § 95.215
      228. § 95.216
      229. § 95.217
      230. § 95.218
      231. § 95.219
      232. § 95.220
      233. § 95.221
      234. § 95.222
      235. § 95.223
      236. § 95.224
      237. § 95.225
      238. § 95.226
      239. § 95.227
      240. § 95.228
      241. SEC. 95.300. BASIC PROVISIONS.
      242. SEC. 95.400. BASIC PROVISIONS.
      243. SEC. 95.500. BASIC PROVISIONS.
      244. SEC. 95.600. BASIC PROVISIONS.
      245. SEC. 95.700. BASIC PROVISIONS.
      246. SEC. 95.800. BASIC PROVISIONS.
      247. SEC. 95.900. BASIC PROVISIONS.
      248. SEC. 95.1000. BASIC PROVISIONS.
      249. SEC. 95.1100. BASIC PROVISIONS.
      250. SEC. 95.1200. BASIC PROVISIONS.
      251. SEC. 95.1300. BASIC PROVISIONS.
      252. SEC. 95.1400. BASIC PROVISIONS.
      253. SEC. 95.1500. BASIC PROVISIONS.
      254. SEC. 95.1600. BASIC PROVISIONS.
      255. SEC. 95.1700. BASIC PROVISIONS.
      256. SEC. 95.1800. BASIC PROVISIONS.
      257. SEC. 96.02. EXCAVATING, DEPOSITING, DUMPING – EARTH, SAND, GRA…
      258. SEC. 96.05. DECLARING CERTAIN AREA SUBJECT TO INUNDATION AND P…
      259. SEC. 96.200. STATEMENT OF PURPOSE.
      260. SEC. 96.201. DEFINITIONS.
      261. SEC. 96.203. SCOPE AND EFFECT OF APPROVALS.
      262. SEC. 96.204. ISSUANCE OF APPROVALS – PROCEDURES.
      263. SEC. 96.205. SUSPENSION AND REVOCATION OF APPROVALS.
      264. SEC. 96.300. INTENT.
      265. SEC. 96.301. DEFINITIONS.
      266. SEC. 96.302. REPORTS REQUIRED.
      267. SEC. 96.303. APPLICATION.
      268. SEC. 96.304. CONTENTS OF REPORTS.
      269. SEC. 96.305. FEE FOR REPORTS.
      270. SEC. 96.306. EFFECTIVE PERIOD OF REPORT.
      271. SEC. 96.307. DELIVERY OF THE REPORT.
      272. SEC. 96.308. EXCEPTIONS.
      273. SEC. 96.309. NON-COMPLIANCE NOT TO INVALIDATE SALE OR EXCHANGE…
      274. SEC. 96.310. EFFECTIVE DATE.
    317. Article 7
    318. Article 8
    319. Article 9
  3. Chapter XV
  4. Chapter XVI

GoCodebook provides public access, search, citation, multilingual explanation, and practical interpretation of legally adopted building regulations. It is not a substitute for the official ICC or California code publications.