Food service ranges shall be installed to provide clearance to combustible material of not less than 18 inches (457 mm) horizontally for a distance up to 2 feet (610 mm) above the surface of the cooking top where the combustible material is not completely shielded by high shelving, a warming closet, or other system. Reduced combustible material clearances are permitted where protected in accordance with Table 303.10.1.