Chapter 9 — INSTALLATION OF SPECIFIC APPLIANCES
917.5 Combustible Material Adjacent to Cooking Top — 2025 California Mechanical Code
California Mechanical Code (Title 24, Part 4) · 2025 edition · updated 2026-10-19 · California
CBSC: official editions, supplements and errata
Italicized text is a California amendment to the model code, as printed in the official publication.
Cite as: 2025 California Mechanical Code (Title 24, Part 4) § 917.5 · Effective January 1, 2026 · Official source: Building Standards Commission
Food service ranges shall be installed to provide clearance to combustible material of not less than 18 inches (457 mm) horizontally for a distance up to 2 feet (610 mm) above the surface of the cooking top where the combustible material is not completely shielded by high shelving, a warming closet, or other system. Reduced combustible material clearances are permitted where protected in accordance with Table 303.10.1.
[NFPA 54:10.11.5]