Appendix 2 Quality Control Plans and Identity of Interest
A.5.3.1.2 Exempt Properties
HUD Multifamily Accelerated Processing (MAP) Guide, HUD Handbook 4430.G (2020 ed., rev. Mar. 19, 2021) · 2026 edition · updated 2026-10-05 · United States
A. Benchmark Buildings. A “benchmark building” is an existing building originally built to or later retrofitted to an identified design code that equals or exceeds the standards defined by ASCE 41-13. A licensed design professional experienced with lateral force design must determine whether a building is a “benchmark building.” The design professional must review the plans (if available) and perform a site visit to confirm that the building does, in fact, meet the benchmark building code. If a determination cannot be made by this means, a Seismic Report must be completed.
B. Exempt Buildings. Many buildings are exempt from the seismic hazard and building performance analysis required by ASCE 41-13. A property composed of exempt buildings as defined below do not require a Seismic Report:
Any single-story, wood or steel frame building with total building area equal to or less than 3,000 square feet.
Any single-story accessory building (i.e., no dwellings in structure).
Any detached or semi-detached structure where the Design Earthquake Spectral Response Acceleration Parameter SXS for hazard level BSE-1E is less than .400 g.
MAP Guide, March 2021 Go to beginning of Appendix 5
Bookmarked Version Go to Acronym and Abbreviation List, Glossary, Index
Appendix 5 Page A5-19
To return to this page after clicking a link, press ALT + Back Arrow
Appendix 5 Architectural and Construction Analysis A.5.3 Seismic Resistance and Fire Protection
Go to Table of Contents
Any building on a site with both Design Earthquake Spectral Response Acceleration Parameters of:
- SXS for hazard level of BSE-1E is less than .330 g; and
- SX1 for hazard level of BSE-1E is less than .133 g.